Description
1. Defibrillation spare ready for emergencies
Keep your Metrax Primedic defibrillator always operational with this pair of adult radiotransparent defibrillation electrodes with external cable (Ref. Cahnos F7760W). Designed as a direct replacement for the Heartsave family pads, they offer a reliable solution for emergency services, ambulances, health centres, companies and any facility with an AED in service. With their external cable configuration, you can connect the electrodes to the device in seconds, without opening or handling the packaging at the critical moment, and leave the patient’s chest visible for radiological imaging without interference.
2. How these electrodes work with your defibrillator
These pads are disposable single-use multifunction electrodes: they perform external defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the discharge energy; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest. Being radiotransparent, the electrode and its cable do not generate artefacts in fluoroscopy, tomography or intraoperative monitoring, allowing the healthcare team to assess the rib cage, pacemaker or vascular access without removing the pads. They are intended for single-patient use: after resuscitation they must be discarded and replaced, always respecting the expiry date on the packaging.
3. Technical specifications and compatibility
Main features of the series of adult radiotransparent electrodes with external cable to which this reference belongs:
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7760W |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Electrode type | Disposable multifunction: defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Cable configuration | External cable: connector and cable outside the pouch, immediate connection |
| Composition | Medical foam (1 mm), low-impedance conductive adhesive gel, metal foil and anti-shock connector |
| Supported shocks | 50 shocks up to 360 J |
| ECG Monitoring | Max. 24 h |
| Compatibility | Metrax Primedic: Heartsave AED (up to s/n 73944xxxxxx), Heartsave AED-M (up to s/n 73945xxxxxx), Heartsave 6 (up to s/n 73946xxxxxx), Heartsave 6S (up to s/n 73947xxxxxx) and Defimonitor XD |
| Use | Single patient — do not reuse |
| Latex / phthalates | Free from latex and phthalates |
| Regulatory classification | Class IIb medical device (Directive 93/42/EEC); ANSI/AAMI DF-80; IEC/EN 60601-1 and 60601-2-4; ISO 10993-10 |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | +5 °C to +35 °C (dry place, out of direct sunlight) |
| Shelf life | 30 months from the date of manufacture |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box |
4. Equivalences and Cross-References
Reference F7760W is confirmed in the manufacturer’s official electrode catalogue as a pair of radiotransparent multifunction electrodes with external cable for Metrax Primedic equipment, supplied in packs of 10 pairs per box. The original equipment manufacturer references (Primedic / Metrax) covering the same clinical platform are listed below, verified through authorised European technical distribution:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Primedic (Metrax GmbH) | Original adult SavePads for HeartSave AS / AED / AED-M / PAD — 3-point connector | 96343 | Comparable by category (not interchangeable 1:1) | Original equipment manufacturer reference for the generation with 3-point connector; it shares the HeartSave platform but is not radiotransparent and the cable is inside the bag. Confirmed in authorised distribution (Medical Cardio, VLAD). Verify connector and serial number range. |
| Primedic (Metrax GmbH) | Original SavePads for HeartSave AED before 2014 | 96387 | Comparable by category (not interchangeable 1:1) | First-generation original intended for AEDs manufactured before 2014; same group of devices within the serial number range, with differences in connector and packaging format. Confirmed in authorised distribution (Medisolinternational, VLAD). |
| Primedic (Metrax GmbH) | Original adult SavePads PreConnect (new generation, from 2014) | 97085 | Comparable by category (not interchangeable 1:1) | Pre-connected 12-point connector for PAD / AED / AED-M with F-code 0214 / 0314 / 0414; it does not replace this reference 1:1 in devices with a different connector generation. Confirmed in authorised distribution (Medical Cardio). |
There is no equivalence table validated by the manufacturer (Primedic / Metrax) cross-referencing this reference with electrodes from other defibrillator manufacturers: defibrillation platforms use proprietary connectors and discharge protocols and are not interchangeable 1:1 between brands (e.g. Philips HeartStart, ZOLL, Stryker LIFEPAK or Bexen). Consult the technical department before using in tenders.
5. Selection tips and variants of interest
- Identify the generation of your device: verify the exact model and serial number printed on the defibrillator label. This reference covers Heartsave AED, AED-M, 6, 6S up to the indicated serial numbers and Defimonitor XD; do not use it on devices outside the range or on other platforms.
- Spare part selection: in mixed fleets, check the connector type of each unit (3-point, pre-connected 12-point or this reference’s connector) before consolidating the order. Do not mix generations.
- Prior verification: check the expiry date and integrity of the heat-sealed bag before installation; do not use open, damaged or expired packaging.
- Variants of the same family at Cahnos: if your device supports the standard non-radiotransparent format with external cable, see reference F7960W; for other platforms in the same radiotransparent category with external cable, F7750W (Philips), F7752W (Physio-Control / Bexen / Mindray) and F7755W (Nihon Kohden / Welch Allyn / Dräger) are available.
- Institutional orders: for consortia, tenders or fleet maintenance, contact our technical-commercial department indicating models and serial numbers; we will confirm compatibility before formalising the order.