Description
1. Commercial Introduction
Keep your defibrillator always ready for emergencies with these compatible, disposable adult defibrillation electrodes (ref. GM33577), the ideal replacement consumable for emergency services, critical care units, ambulances and heart-protected areas equipped with equipment from the Agilent Hewlett-Packard and Laerdal Medical families. With a single reference it covers the most widespread defibrillator-monitor fleets of these brands —CodeMaster 100, XE, XL and XL+, Heartstream XL/XLT and HeartStart 4000—, simplifying the stock of resuscitation consumables. BSI certified for adult patients (over 8 years or 25 kg), they are sold in a kit of 2 units (GM33577) and in a pack of 10 pairs (GM55022) for centres with higher turnover. For large orders you can request a quote: contact our technical-commercial team.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency electrocardiographic monitoring. This adult pair is indicated for patients over 8 years of age or weighing more than 25 kg and is manufactured with a conductive adhesive gel that ensures excellent adhesion to the skin and adequate thickness, guaranteeing low interface impedance and optimal energy transmission during assistance. The set includes a pair of electrodes, the connection cable and the specific connector for the platform. They are single-use and disposable: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams on the envelope. Made in Italy, they are latex-free and comply with the requirements of Directive 93/42/EEC and its amendments as a class IIb medical device.
3. Technical Specifications
Adult compatible electrodes certified by BSI, complying with Directive 93/42/EEC and amendments (class IIb medical device) and standards ANSI/AAMI DF-80, IEC/EN 60601-1, IEC/EN 60601-2-4 and ISO 10993-1.
General characteristics
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C020401 |
| GMDN | 47055 |
| Use | Adult – disposable, single-use |
| Indicated population | Patients >8 years (25 kg) |
| Kit contents | Pair of electrodes, cable and connector |
| Adhesion and gel | Excellent adhesion and adequate gel thickness |
| Material | Latex-free |
| Maximum shelf life | 30 months from the date of production |
| Certifications | BSI; ANSI/AAMI: DF-80; IEC/EN: 60601-1, 60601-2-4; ISO: 10993-1 |
| Conformity | Directive 93/42/EEC and amendments (Class IIb) |
| Packaging | Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU |
| Manufacture | Made in Italy |
Available references
References GM33577 and GM55022 correspond to the same compatible electrode in different sales presentations, according to the manufacturer’s official catalogue. Always keep the manufacturer’s reference (33577 / 55022) when placing the order.
| Reference | Model | Sales unit |
|---|---|---|
| GM33577 | Compatible electrodes for Agilent, H-P and Laerdal defibrillators (see also 55022) | Kit of 2 units |
| GM55022 | Compatible electrodes for Agilent, H-P and Laerdal defibrillators | 10 pairs |
Compatibility with defibrillators
| Brand | Compatible models |
|---|---|
| Agilent Hewlett-Packard | CodeMaster 100, XE, XL, XL+ |
| Agilent Hewlett-Packard | Heartstream XL, XLT, XL+ (with cable M3507A) |
| Laerdal Medical | HeartStart 4000 |
4. Equivalences and Cross-References
References 33577 (kit of 2 units) and 55022 (10 pairs) correspond to the same compatible electrode in different sales presentations, according to the manufacturer’s official catalogue. This consumable is a compatible replacement for the cited Agilent Hewlett-Packard and Laerdal Medical defibrillators, not an original spare part certified by each equipment manufacturer: the connector, the analysis algorithm and energy management are proprietary. After verifying official catalogues and regulatory databases, the following comparable cross-references are identified at category level (not interchangeable 1:1):
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level |
|---|---|---|---|
| Philips Healthcare | Adult Multifunction Pads, IEC barrel connector (platform original) | M3502A (alternative 989803106931) | Comparable by category (not interchangeable 1:1) |
| Philips Healthcare | HeartStart Adult Defibrillator Pads (AED FR2/FR2+ / ForeRunner) | 989803158211 (1 pair) / 989803158221 (5 pairs) | Comparable by category (not interchangeable 1:1) |
| Cardinal Health (Covidien) | Medi-Trace Cadence adult RTS (radiotransparent) | 22661R (preconnected: 22661PC) | Comparable by category (not interchangeable 1:1) |
| Nissha Medical Technologies (HeartSync) | 97-DEFIB F/G C100AC-PHILIPS | 6600015H | Comparable by category (not interchangeable 1:1) |
| Leonhard Lang | Skintact® Easibeat – adult multifunction electrodes Philips CodeMaster | DF26N | Comparable by category (not interchangeable 1:1) |
There is no equivalence table validated by the manufacturer that authorises the replacement of original electrodes with third-party pads: the connector, the analysis algorithm and energy management are proprietary to each platform. Any replacement must be validated against the technical data sheet and instructions for use of the defibrillator, checking one by one the connector, the energy range, the target population and the expiry date. Consult the technical department of Cahnos before using in tenders.
5. Selection tips and variants of interest
Confirm the model of your device: verify on the defibrillator plate that your model is among the compatible ones (CodeMaster 100/XE/XL/XL+, Heartstream XL/XLT/XL+ or HeartStart 4000) and that the connector, as well as the M3507A cable in models that require it, fits correctly into the electrode socket before clinical use.
Presentation and volume: reference GM33577 is sold in a kit of 2 units for individual replacement and GM55022 in a format of 10 pairs for fleets, ambulances, centres with several devices or high-turnover stock replenishment.
Range of compatible electrodes at Cahnos: within the same family you will find the specific references according to the equipment manufacturer: Nihon Kohden (GM33575), Agilent-Philips (GM33576), Defibtech Lifeline (GM33578) and Drager/Innomed/S&W/Welch Allyn (GM33579). Each platform requires its specific reference: they are not interchangeable with each other due to the proprietary connector.
Shelf life and storage: the maximum shelf life is 30 months from the date of production. Store in a dry place, at moderate temperature, and respect the expiry date printed on the packaging; the conductive gel may dry out and reduce its conductivity if exceeded. As it is a single-use consumable, maintain a minimum stock per defibrillator unit and rotate stock by expiry date (FIFO method). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact models of your equipment.