Description
1. Commercial Introduction
Keep your defibrillator or defibrillator monitor from the Schiller family always ready with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7967W). It is the replacement consumable indicated for defibrillation of adult patients with the FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy and Defigard Touch 7 equipment.
It is supplied per pair (2 units) in an individual heat-sealed pouch and is ready to be integrated into the cardiopulmonary resuscitation protocols of emergency services, ambulances, hospitals, health centres, companies and cardioprotected spaces equipped with Schiller. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables emergency ECG monitoring. This pair is indicated for adult patients (over 8 years of age or weighing more than 25 kg) and connects to the electrode socket of the aforementioned Schiller equipment through its external cable configuration: the pouch contains the cable and connector, ready to be plugged into the device at the time of care.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam backing adapts to the contours of the chest. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams printed on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the pouch.
3. Technical Specifications
3.1 Product identification
| Reference Cahnos (SKU) | F7967W |
| Product type | Pair of standard adult multifunction defibrillator electrodes, with external cable |
| Compatible equipment brand | Schiller – FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy, Defigard Touch 7 |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed packaging; 10 pairs per box in the adult range |
3.2 Technical features
| Parameter | Specification |
| Target population | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | External cable (plug-in connector included in the pouch; not pre-connected) |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector or clip (depending on model), with external cable |
| Maximum ECG monitoring time | Up to 24 h |
| Operating temperature | Between 0 °C and +50 °C |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium pouch, with laser pre-cut and opening notch |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
3.3 Compatible equipment
| Equipment brand | Compatible models |
| Schiller | FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy, Defigard Touch 7 |
Technical note: the values for active surface area (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with external cable in this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
4. Equivalences and Cross-References
This electrode (SKU F7967W) belongs to the family of standard adult consumables with external cable for defibrillation. The original replacement from the equipment manufacturer, Schiller, is identified by code 2.155061 (adult electrodes in heat-sealed pouch, with cable and connector not pre-connected, for FRED easyport, FRED easyport plus, Argus Pro LifeCare 1 and 2, Cardiovit AT-101 easy, Defigard Touch 7 and Physiogard Touch 7) and by the pre-connected variant 2.155065 (also referenced as 0-21-00-40), consistently verified at authorised distributors of original Schiller spare parts. Equivalences with other brands are comparable only at category level: the connector, the analysis algorithm and the energy management are proprietary to each device, so they are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller (original equipment replacement) | Adult electrodes FRED easyport / FRED easyport plus / FRED PA-1 (adult pads) | 2.155061 (not pre-connected) / 2.155065 (pre-connected, ref. 0-21-00-40) | Comparable by category (not interchangeable 1:1) | Original factory replacement for the same equipment family (FRED easyport, FRED easyport plus, FRED PA-1, Argus Pro LifeCare 1/2, Cardiovit AT-101 easy, Defigard Touch 7, Physiogard Touch 7 and Defigard HD-7). Version 2.155061 comes with cable and connector inside the pouch (not pre-connected), just like this compatible replacement; the 2.155065 is pre-connected with RFID tag for FRED PA-1. Codes confirmed at authorised distributors of original Schiller spare parts; the replacement of the original by the compatible Cahnos spare part must be validated against the technical data sheet and IFU of the equipment. |
| ZOLL Medical | Stat-Padz® II (adult electrodes for AED Plus / AED Pro) | 8900-0801-01 (pair) / 8900-0802-01 (multipack) | Comparable by category (not interchangeable 1:1) | Factory original pre-connected for the ZOLL AED Plus and AED Pro AEDs; polymer conductive gel, tin conductive element and own energy levels. Code confirmed in ZOLL technical documentation and authorised distribution (GUDID). Not suitable for Schiller equipment due to proprietary connector and algorithm. |
Other market families that address the same clinical indication (adult multifunction electrodes for professional defibrillators and AEDs) are the Philips HeartStart SMART Pads, the CONMED PadPro® and the Leonhard Lang Skintact®; in all cases, the connector, energy range and equipment algorithm must be verified before considering any replacement, which is why they are not listed here with a code as there is no validated cross-reference with the Schiller platform.
Within the Cahnos catalogue there are other references in the same family intended for equipment from other manufacturers, not interchangeable with each other as the connector and algorithm differ: F7957W (Cardiac Science / GE), F7961W (Nihon Kohden), F7960W (Metrax Primedic) or F7987W (ZOLL). The adult version with internal cable in this same Schiller family is the F7967, and the paediatric variants for the same equipment are the F7967PW (external cable) and the F7967P (internal cable).
There is no equivalence table validated by the manufacturer that authorises the replacement of the original Schiller electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the Cahnos technical department before using in a tender.
5. Selection tips and variants of interest
- Confirm the equipment model: verify that your defibrillator is a Schiller FRED EasyPort, FRED PA-1, Argus Pro LifeCare, Argus Pro LifeCare 2, Cardiovit AT-101 Easy or Defigard Touch 7 and that the external cable connector fits correctly into the equipment socket before clinical use; if in doubt, contact the Cahnos technical department stating the model and serial number.
- Do not confuse versions: this pair is for adult patients (over 8 years or over 25 kg). For the same paediatric family use the F7967PW (external cable) or the F7967P (internal cable); if you prefer an internal cable for adults, the reference is the F7967.
- External cable vs pre-connected: the external cable configuration leaves the connector accessible to plug the pair into the equipment at the precise moment; if your workflow requires leaving the equipment permanently connected, consider the original pre-connected variant from Schiller (2.155065).
- Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with damaged packaging, as the gel may lose conductivity.
- Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method). For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of your equipment.