Standard adult defibrillator electrode pair with external cable – Compatible replacement for Cardiac Science Powerheart AED series 9200 / G3 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED / AED Pro – Ref. F7957W

34,98 €

Standard adult defibrillator electrode pair with external cable (Ref. F7957W), compatible replacement for the Cardiac Science Powerheart AED series 9200 and G3 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED / AED Pro defibrillators. Single-use multifunction pads for adult patients (over 8 years / over 25 kg), with low-impedance conductive adhesive gel, metal foil and 1 mm medical foam backing: 148 cm² total area and 95 cm² active area per electrode, up to 50 shocks at 360 J and ECG monitoring for up to 24 h. Its external cable configuration allows the equipment to be left pre-connected and operational in seconds. Class IIb medical device, latex-free and phthalate-free; sold as a pair with immediate dispatch.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7957W

Description

1. Commercial Introduction

Keep your defibrillator always ready to act with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7957W), a replacement consumable compatible with the defibrillators of the Cardiac Science Powerheart families (AED 9200 and G3 9300 series), FirstSave G3 and General Electric Responder AED / AED Pro. It is the indicated solution for emergency services, ambulances, companies, sports centres, hospitals and any heart-safe space equipped with these devices.

Thanks to its external cable configuration, the connector remains accessible without opening the sealed pouch: the pair can be left pre-connected to the device and, at the critical moment, you only need to remove the protective cover and place the pads following the anatomical diagrams on the packaging. It is sold per pair (2 units) with immediate dispatch and specialised technical support from Cahnos.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the biphasic transthoracic shock and allows emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years old or over 25 kg) in defibrillation, synchronised cardioversion and ECG monitoring.

The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal energy transmission; the inner metallic foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), according to the diagrams on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Features of the series of standard adult electrodes with external cable to which this reference belongs:

Parameter Specification
Reference Cahnos (SKU) F7957W
Product type Pair of adult multifunction defibrillator electrodes, standard, with external cable
Brand / compatible equipment Cardiac Science Powerheart AED 9200, Powerheart AED G3 9300 (G3, G3 Plus, G3 Pro), FirstSave G3; GE Responder AED and Responder AED Pro; verify connector fit in the device socket
Patient type Adult (older than 8 years / more than 25 kg)
Cable configuration External cable (pre-connected connection), approximate length 120–130 cm in the series
Total surface (per electrode) 148 cm²
Active surface (per electrode) 95 cm²
Adhesive ring width 1 cm
Supported shocks Up to 50 shocks (50 to 360 J)
Functions Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (1 mm thick)
Connection type Specific anti-shock safety connector, external cable
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Shelf life Approx. 30 months from the date of manufacture; expiry date indicated on the packaging
Storage Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C
Presentation Price per pair of electrodes (2 units); 1 pair in heat-sealed polyethylene and aluminium bag (10 pairs per box in adult series)

Compatible equipment:

Brand Compatible models
Cardiac Science Powerheart AED series 9200; Powerheart AED G3 series 9300 (G3, G3 Plus, G3 Pro); FirstSave AED G3 series 9300
General Electric (GE) GE Responder AED and GE Responder AED Pro

Note: the values for active surface (95 cm²), total area (148 cm²), shocks (50 to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with external cable of this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tendering.

4. Equivalences and Cross-References

This electrode (SKU F7957W) is a consumable compatible with Cardiac Science Powerheart and GE Responder AED / AED Pro defibrillators, not an original spare part certified by the device manufacturer: the connector, analysis algorithm and energy management are proprietary to each defibrillator. The original factory reference for these devices is the Cardiac Science 9131-001 (Powerheart® Adult Defibrillation Pads), verified in the GUDID/FDA regulatory database (UDI-DI 00812394020911 / 00812394020102) and in the official ZOLL store; under GE numbering it is documented as 2019199-002 in the GE Responder AED operator’s manual (UDI-DI 00812394020591). Equivalences with other brands are classified as comparable by category, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cardiac Science (ZOLL) Powerheart® Adult Defibrillation Pads 9131-001 Comparable by category (not interchangeable 1:1) Factory original (OEM) for the same Powerheart series 9200/9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and Survivalink devices; non-polarised and with original proprietary connector. Code verified in GUDID/FDA and in the official ZOLL store.
General Electric (GE) Powerheart® Adult Defibrillation Pads under GE number (Responder AED / AED Pro) 2019199-002 Comparable by category (not interchangeable 1:1) Same Cardiac Science part referenced under GE number, documented in the GE Responder AED operator’s manual (2019199-003 is the paediatric variant). Verified in GUDID (UDI-DI 00812394020591).
Heart Sync Inc (Nissha Medical) Heart Sync T-CardiacSci-AED™ Pads T100-CS Comparable by category (not interchangeable 1:1) Third-party electrode declared by its manufacturer as a substitute for the 9131-001 for Cardiac Science devices; indicated in patients >8 years / >55 lb with monitoring <8 h according to IFU. Code verified in GUDID (UDI-DI 00868866000004).
AED Brands, LLC Adult electrodes for Cardiac Science AEDs AB 9131-001 Comparable by category (not interchangeable 1:1) Third-party electrode declared as a replacement for the 9131-001 in Cardiac Science defibrillators. Code verified in GUDID (UDI-DI 90865292000106).

There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes 9131-001 / 2019199-002 with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department at Cahnos before using in tenders. Within the Cahnos catalogue there are other references in the same family (standard adult with external cable) intended for equipment from other manufacturers, not interchangeable with each other as the connector and algorithm differ: F7950W (Philips), F7952W (Physio-Control / Bexen / Cardioline / Mindray), F7958W (CU Medical Paramedic), F7959W (CU Medical i-PAD / CMOS Drake), F7967W (Schiller) and F7987W (ZOLL AED).

5. Selection tips and variants of interest

Confirm the equipment model: this pair corresponds to the Cardiac Science Powerheart AED series 9200, Powerheart AED G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and the GE Responder AED / AED Pro defibrillators. Verify that the external cable connector fits correctly into the electrode socket before clinical use; it is not valid for equipment with a different connector.

Do not confuse versions: this pair is for adult patients (over 8 years or over 25 kg). For the paediatric population with the same equipment, use the F7957WPL (energy limited 200 J → 50 J with external cable) or the F7957PL (energy limited with 120 cm internal cable).

External cable vs pre-connected: the external cable configuration leaves the connector accessible for plugging the pair into the equipment instantly; if your workflow requires the AED to remain permanently connected, this variant allows it without opening the sealed pouch.

Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or electrodes with a damaged pouch, as the gel may lose conductivity.

Plan your replacement: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO). For volume orders or tenders, contact the technical department at Cahnos stating the exact model and serial number of your defibrillator.

Additional information

Reference

F7957W

Manufacturer reference

Cardiac Science 9131-001; GE 2019199-002

Product type

Pair of adult multifunction defibrillator electrodes, standard, with external cable

Compatibility

Cardiac Science Powerheart AED 9200 / G3 9300 (G3, G3 Plus, G3 Pro), FirstSave G3; GE Responder AED / AED Pro

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

External cable (pre-connected connection), approx. 120–130 cm

Total surface

148 cm² per electrode

Active surface

95 cm² per electrode

Adhesive ring width

1 cm

Supported shocks

Up to 50 shocks (50 to 360 J)

Functions

Defibrillation, synchronized cardioversion and ECG monitoring

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam

Connection type

Specific anti-shock safety connector, external cable

Use

Single-use, disposable, non-sterile

Classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from date of manufacture

Storage

Dry place, +5 °C to +35 °C; operation 0 °C to +50 °C

Presentation

1 pair (2 units); heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series)

Indicated population

Adults (over 8 years / over 25 kg)

Total surface per electrode

148 cm²

Active surface per electrode

95 cm²

ECG monitoring

Max. 24 h

Latex, phthalates

Latex-free and phthalate-free

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)