1. Commercial Introduction
Keep your Corpuls defibrillator-monitor always ready to respond in the care of adult patients with this pair of radiopaque defibrillation electrodes with external cable (lead out), reference F7965W/NG from the Italian manufacturer FIAB. Specifically designed for the equipment of the Corpuls platform, these multifunction patches ensure optimal shock delivery and reliable monitoring of the emergency electrocardiogram, even when the patient is to undergo imaging tests.
Its packaging is specially designed for onboard positioning on the defibrillator, so that the device can be transported and deployed in the shortest possible time, a decisive advantage in ambulances, emergency services, intensive care units and any clinical environment equipped with Corpuls.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and enables monitoring of the emergency ECG. This pair is indicated for adult patients in external defibrillation, synchronized cardioversion and continuous electrocardiographic recording.
The distinguishing feature of this reference is its condition as a radiopaque electrode: it does not interfere with the reading of imaging tests and maintains its functionality without the need to remove it from the patient, something especially valuable in prehospital care and in critically ill patients who require radiography, CT or fluoroscopy during transport or in hospital. The configuration with external cable (lead out) leaves the connector accessible outside the sealed bag, allowing the pair to be connected to the device immediately and stably, without handling the packaging at the critical moment.
They are single-use and disposable: do not reuse under any circumstances and replace after each procedure or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7965W/NG |
| Packaging | 10 pairs per box |
| Units per box (web) | 10 |
| Compatible with | Corpuls |
Relevant technical data
| Parameter | Specification |
|---|---|
| Brand | FIAB (FIAB SpA – Vicchio, Florence, Italy) |
| Product type | Pair of adult multifunction defibrillation electrodes |
| Target population | Adult |
| Radiopacity | Yes (radiopaque electrodes) |
| Cable configuration | External cable (lead out) |
| Presentation | Sold per pair; 10 pairs per box |
| Use | Single-use, disposable |
Note: the highlighted technical data correspond to the verified information from the manufacturer’s catalogue; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
4. Equivalences and Cross-References
Reference F7965W/NG is the original code from FIAB for this pair of radiopaque electrodes with external cable compatible with the Corpuls platform (SKU Cahnos FIAB-F7965W-NG). The connector, analysis algorithm and energy management of each defibrillator are proprietary, so there is no equivalence table validated by the manufacturer that authorises the replacement of these electrodes with patches from other brands without prior verification: any replacement must be validated against the technical data sheet and instructions for use of the defibrillator, and consulted with the technical department of Cahnos before using it in tendering.
Within the Cahnos catalogue there are related references from the same family of connectors for Corpuls equipment: the F7965 (standard adult with internal cable), the F7965/PLUS (standard adult pre-connected) and the F7965P (paediatric with internal cable, original replacement 05120.3). They are not interchangeable with each other as the cable configuration differs and, in the paediatric case, the energy management.
5. Selection tips and variants of interest
Confirm the equipment model: verify that your defibrillator-monitor belongs to the Corpuls platform and that the external cable connector fits correctly into the electrode socket before clinical use. If in doubt, contact the technical department of Cahnos stating the model and serial number of the device.
Radiopaque advantage: if your workflow anticipates radiography, CT or fluoroscopy during care, this radiopaque version avoids removing the electrode and maintains continuous monitoring. If you do not need this feature and prefer a pre-connected internal cable, consider reference F7965 (standard adult with internal cable).
Paediatric use: this pair is for adult patients. For the paediatric population with Corpuls equipment, use reference F7965P (paediatric with internal cable), always verifying the paediatric energy mode of the device.
Storage and expiry: always check the date printed on the packaging and store in a dry, protected place; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock by expiry date (FIFO).