Description
1. Commercial Introduction
Keep your Laerdal Medical/Philips defibrillator always ready to act with this pair of standard adult defibrillator electrodes with internal cable and Snap connection (reference Cahnos F7970). It is the recommended replacement consumable for defibrillation of adult patients in equipment that works with Laerdal internal cables with Snap connection: HeartStart 3000, HeartStart 911 and the MRx, FR (series) and XL families.
It is sold as a pair (2 units) and is designed for emergency services, ICU, ambulances, cardiology clinics and any heart-safe space with Laerdal/Philips equipment. Available with immediate dispatch from Cahnos and with specialised technical support for compatibility verification by model and connector before placing the order.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock, allows synchronised cardioversion, non-invasive transcutaneous pacing (if the equipment supports it) and emergency ECG monitoring.
This adult model (patients over 8 years old or weighing more than 25 kg) is constructed with low-impedance conductive adhesive gel, which ensures homogeneous contact with the skin and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns.
The version with internal cable does not include an external cable: the pad attaches directly via Snap-type anti-shock safety connector (clip) onto the equipment’s internal cable, ensuring a firm and quick connection in an emergency, without loose cables during resuscitation. The recommended placement is anterolateral (sternum-apex), according to the anatomical diagrams on the packaging. They are single-use: replace after each intervention or upon reaching the expiry date printed on the packaging; do not reuse under any circumstances.
3. Technical Specifications
Main features of the standard adult electrode series with internal cable to which this reference belongs:
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7970 |
| Product type | Pair of adult multifunction defibrillator electrodes, standard, with internal cable (leads-in) and Snap connector |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | Internal cable (integrated), direct connection to the equipment cable |
| Connection type | Snap-type anti-shock safety connector (press stud) |
| Total surface (per electrode) | 148 cm² (standard adult series) |
| Active surface (per electrode) | 95 cm² (standard adult series) |
| Adhesive ring width | 1 cm |
| Supported shocks | 50 to 360 J (up to 50 shocks) |
| Functions | External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring |
| ECG monitoring | Max. 24 h |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Presentation | Price per pair (2 units); 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series) |
| Shelf life | Approx. 30 months from the date of manufacture (expiry date indicated on the packaging) |
| Storage | Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Note: the values for active surface (95 cm²), total area (148 cm²), shocks (50 to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
3.1 Compatibility with cables and equipment (according to distributor commercial documentation)
| Laerdal Medical cable | Cited compatible equipment |
|---|---|
| Ref. 945004 | Supplied with Philips MRx, FR (series) and XL defibrillators |
| Ref. 920601 / Ref. 920602 | Supplied with the HeartStart 3000 defibrillator |
Note: codes 945004, 920601 and 920602 correspond to internal cables of the Laerdal/Philips family cited in the distributor’s documentation for compatibility identification purposes; they are not pad codes from the electrode manufacturer. Always confirm the cable and the exact model of your equipment before clinical use.
4. Equivalences and Cross-References
Reference F7970 is the Cahnos distribution code for this compatible electrode; it is not an official reference from the equipment manufacturer. Laerdal Medical/Philips do not publish an F7970 code: codes 945004, 920601 and 920602 appear in the distributor’s commercial documentation as internal cable references for the Laerdal/Philips family and could not be verified as pad codes in public sources (GUDID/EUDAMED with no results), so their correspondence must be confirmed with the technical department before use in tendering. Comparisons with other brands are understood at category level: the connector, analysis algorithm and energy management are proprietary to each equipment.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips | HeartStart Adult Defibrillator Pads – original adult electrodes for the AEDs of the HeartStart FR2/FR2+ and ForeRunner family | 989803158211 (1 pair) / 989803158221 (5 pairs) | Comparable by category (not interchangeable 1:1) | Factory original for patients ≥8 years or ≥25 kg; plug-type connector of the AED platform (not Snap) and proprietary algorithm. Code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Verify connector and cable before replacement. |
| Philips | Adult/Child Pads with barrel connector – original multifunction electrodes from the CodeMaster / HeartStream / HeartStart family | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Genuine factory original for the Philips barrel connector platform; covers adult and adult/child population (≥10 kg) and requires the M3507A/M3508A cables depending on the model. Code documented in the Philips technical specification sheet and in GUDID. Does not use Snap connector; not interchangeable 1:1. |
| ZOLL Medical | Stat-Padz® II – adult multifunction electrodes | 8900-0801-01 | Comparable by category (not interchangeable 1:1) | Genuine factory pre-connected for AED Plus and AED Pro (without detachable internal cable); proprietary ZOLL connector and its own energy levels. Code confirmed in technical data sheet and GUDID. Not suitable for Laerdal/Philips equipment due to proprietary connector. |
There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes from the Laerdal/Philips family with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department of Cahnos before use in tenders. Within the Cahnos catalogue there are other references from the same family (standard adult with internal cable and Snap connection) intended for equipment from other manufacturers, not interchangeable with each other: F7971 (Physio-Control LIFEPAK) and F7972 (GE/Marquette and Esaote with cable 22338301). In addition, the same Laerdal Snap connection system is available in a paediatric version under reference F7970P.
5. Selection tips and variants of interest
- Confirm the cable and the equipment model: verify that your defibrillator uses a Laerdal Medical internal cable with Snap connector (cited family: HeartStart 3000 with cables 920601/920602 and HeartStart 911; MRx, FR and XL with cable 945004) and that the clip fits correctly before clinical use.
- Do not confuse adult and paediatric versions: this pair is for patients over 8 years old or over 25 kg. For the paediatric population with the same connector family, the paediatric reference F7970P is available (under 8 years old or under 25 kg).
- Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used, as the gel may lose conductivity.
- Plan your replacement: as it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO).
- Institutional orders: for consortia, tenders or fleet maintenance, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your equipment; we will confirm compatibility before formalising the order.






Reviews