We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Standard adult defibrillator electrode with internal cable and Snap connection (pair) – Replacement compatible with Laerdal Medical/Philips HeartStart 3000, 911, MRx, FR and XL · Ref. F7970

27,25 €

Pair of adult multifunction defibrillator electrodes with internal cable and Snap connection (Ref. F7970), replacement compatible with Laerdal Medical/Philips defibrillators and monitors that work with internal Snap connection cables (HeartStart 3000, HeartStart 911 and MRx, FR and XL families with cables ref. 945004, 920601 and 920602). Disposable single-use pad for patients over 8 years old or over 25 kg, with active surface of 95 cm² per electrode, low-impedance conductive adhesive gel, metal foil and 1 mm medical foam backing. Supports up to 50 shocks from 50 to 360 J, allows defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring for up to 24 h. Latex-free and phthalate-free, class IIb medical device: always verify the cable and the exact model of your equipment. Sold as a pair.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7970

Description

1. Commercial Introduction

Keep your Laerdal Medical/Philips defibrillator always ready to act with this pair of standard adult defibrillator electrodes with internal cable and Snap connection (reference Cahnos F7970). It is the recommended replacement consumable for defibrillation of adult patients in equipment that works with Laerdal internal cables with Snap connection: HeartStart 3000, HeartStart 911 and the MRx, FR (series) and XL families.

It is sold as a pair (2 units) and is designed for emergency services, ICU, ambulances, cardiology clinics and any heart-safe space with Laerdal/Philips equipment. Available with immediate dispatch from Cahnos and with specialised technical support for compatibility verification by model and connector before placing the order.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock, allows synchronised cardioversion, non-invasive transcutaneous pacing (if the equipment supports it) and emergency ECG monitoring.

This adult model (patients over 8 years old or weighing more than 25 kg) is constructed with low-impedance conductive adhesive gel, which ensures homogeneous contact with the skin and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns.

The version with internal cable does not include an external cable: the pad attaches directly via Snap-type anti-shock safety connector (clip) onto the equipment’s internal cable, ensuring a firm and quick connection in an emergency, without loose cables during resuscitation. The recommended placement is anterolateral (sternum-apex), according to the anatomical diagrams on the packaging. They are single-use: replace after each intervention or upon reaching the expiry date printed on the packaging; do not reuse under any circumstances.

3. Technical Specifications

Main features of the standard adult electrode series with internal cable to which this reference belongs:

Parameter Specification
Reference Cahnos (SKU) F7970
Product type Pair of adult multifunction defibrillator electrodes, standard, with internal cable (leads-in) and Snap connector
Patient type Adult (older than 8 years / more than 25 kg)
Cable configuration Internal cable (integrated), direct connection to the equipment cable
Connection type Snap-type anti-shock safety connector (press stud)
Total surface (per electrode) 148 cm² (standard adult series)
Active surface (per electrode) 95 cm² (standard adult series)
Adhesive ring width 1 cm
Supported shocks 50 to 360 J (up to 50 shocks)
Functions External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring
ECG monitoring Max. 24 h
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Presentation Price per pair (2 units); 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series)
Shelf life Approx. 30 months from the date of manufacture (expiry date indicated on the packaging)
Storage Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Note: the values for active surface (95 cm²), total area (148 cm²), shocks (50 to 360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm with the technical data sheet of the supplied batch and the equipment manual before use in tendering.

3.1 Compatibility with cables and equipment (according to distributor commercial documentation)

Laerdal Medical cable Cited compatible equipment
Ref. 945004 Supplied with Philips MRx, FR (series) and XL defibrillators
Ref. 920601 / Ref. 920602 Supplied with the HeartStart 3000 defibrillator

Note: codes 945004, 920601 and 920602 correspond to internal cables of the Laerdal/Philips family cited in the distributor’s documentation for compatibility identification purposes; they are not pad codes from the electrode manufacturer. Always confirm the cable and the exact model of your equipment before clinical use.

4. Equivalences and Cross-References

Reference F7970 is the Cahnos distribution code for this compatible electrode; it is not an official reference from the equipment manufacturer. Laerdal Medical/Philips do not publish an F7970 code: codes 945004, 920601 and 920602 appear in the distributor’s commercial documentation as internal cable references for the Laerdal/Philips family and could not be verified as pad codes in public sources (GUDID/EUDAMED with no results), so their correspondence must be confirmed with the technical department before use in tendering. Comparisons with other brands are understood at category level: the connector, analysis algorithm and energy management are proprietary to each equipment.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips HeartStart Adult Defibrillator Pads – original adult electrodes for the AEDs of the HeartStart FR2/FR2+ and ForeRunner family 989803158211 (1 pair) / 989803158221 (5 pairs) Comparable by category (not interchangeable 1:1) Factory original for patients ≥8 years or ≥25 kg; plug-type connector of the AED platform (not Snap) and proprietary algorithm. Code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Verify connector and cable before replacement.
Philips Adult/Child Pads with barrel connector – original multifunction electrodes from the CodeMaster / HeartStream / HeartStart family M3501A (also 989803106921) Comparable by category (not interchangeable 1:1) Genuine factory original for the Philips barrel connector platform; covers adult and adult/child population (≥10 kg) and requires the M3507A/M3508A cables depending on the model. Code documented in the Philips technical specification sheet and in GUDID. Does not use Snap connector; not interchangeable 1:1.
ZOLL Medical Stat-Padz® II – adult multifunction electrodes 8900-0801-01 Comparable by category (not interchangeable 1:1) Genuine factory pre-connected for AED Plus and AED Pro (without detachable internal cable); proprietary ZOLL connector and its own energy levels. Code confirmed in technical data sheet and GUDID. Not suitable for Laerdal/Philips equipment due to proprietary connector.

There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes from the Laerdal/Philips family with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department of Cahnos before use in tenders. Within the Cahnos catalogue there are other references from the same family (standard adult with internal cable and Snap connection) intended for equipment from other manufacturers, not interchangeable with each other: F7971 (Physio-Control LIFEPAK) and F7972 (GE/Marquette and Esaote with cable 22338301). In addition, the same Laerdal Snap connection system is available in a paediatric version under reference F7970P.

5. Selection tips and variants of interest

  • Confirm the cable and the equipment model: verify that your defibrillator uses a Laerdal Medical internal cable with Snap connector (cited family: HeartStart 3000 with cables 920601/920602 and HeartStart 911; MRx, FR and XL with cable 945004) and that the clip fits correctly before clinical use.
  • Do not confuse adult and paediatric versions: this pair is for patients over 8 years old or over 25 kg. For the paediatric population with the same connector family, the paediatric reference F7970P is available (under 8 years old or under 25 kg).
  • Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used, as the gel may lose conductivity.
  • Plan your replacement: as it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO).
  • Institutional orders: for consortia, tenders or fleet maintenance, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your equipment; we will confirm compatibility before formalising the order.

Additional information

Product type

Pair of adult multifunction defibrillator electrodes, standard, with internal cable (leads-in) and Snap connector

Compatibility

Laerdal Medical / Philips (HeartStart family with Snap connection)

Compatible cables

Ref. 945004 (MRx, FR, XL); Ref. 920601 / 920602 (HeartStart 3000)

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

Internal cable (integrated), direct connection to the equipment cable

Connection type

Snap-type anti-shock safety connector (press stud)

Total surface per electrode

148 cm² (standard adult series)

Active surface per electrode

95 cm² (standard adult series)

Adhesive ring width

1 cm

Supported shocks

50 to 360 J (up to 50 shocks)

Functions

External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring

ECG monitoring

Max. 24 h

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

Medical foam (FOAM) 1 mm thick

Use

Single-use, disposable, non-sterile

Presentation

1 pair (2 electrodes) in heat-sealed polyethylene and aluminium pouch; 10 pairs per box (adult series)

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from the date of manufacture (expiry date indicated on the packaging)

Storage

Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C

Compatible models

HeartStart 3000 (cables 920601/920602), HeartStart 911, MRx, FR (series) and XL families (cable 945004); verify connector fit

Compatible cable references

945004, 920601, 920602 (internal cables of the Laerdal/Philips family; not verifiable as pad codes in public sources)

Latex-free and phthalate-free

Yes

Expiry

Indicated on the packaging; do not use after the expiry date