Description
1. Commercial Introduction
Keep your defibrillator always operational with this pair of radiotransparent adult defibrillator electrodes with internal cable (Ref. Cahnos F7752), a high-reliability replacement consumable compatible with equipment from the Physio-Control LIFEPAK, Cardioline ELIFE 700 and Mindray BeneHeart families. Designed for emergency services, ICU, ambulances, operating theatres, haemodynamics and any cardioprotected space, it combines the advantages of the radiotransparent series —image control without artefacts— with the robustness of the integrated internal cable connection, which avoids loose cables during resuscitation. Available with immediate delivery from Cahnos and specialised technical support for compatibility verification by model and connector before placing the order.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the heart rhythm, delivers the transthoracic shock, allows synchronised cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency ECG monitoring. This pair is indicated for adult patients (over 8 years old or weighing more than 25 kg).
The low-impedance conductive adhesive gel ensures homogeneous skin contact, low interface resistance and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the thorax, minimising the risk of burns. Its radiotransparent condition —in the electrode and the cable— avoids artefacts in X-ray, fluoroscopy and tomography, so the pads can be kept in place during imaging examinations without interrupting monitoring or therapy. The recommended placement is anterolateral (sternum-apex), according to the anatomical diagrams on the packaging. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical specifications and compatibility
3.1 Technical specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | F7752 |
| Product type | Radiotransparent adult multifunction defibrillator electrode pair, with internal cable (leads-in) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Cable configuration | Integrated internal cable (leads-in), approx. 100 cm (series) |
| Functions | External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring |
| Total surface (per electrode) | 136 cm² (adult radiotransparent series) |
| Active surface (per electrode) | 94 cm² (adult radiotransparent series) |
| Adhesive ring width | 0.7 cm |
| Supported shocks | Up to 50 shocks at 360 J |
| ECG monitoring | Max. 24 h |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (1 mm thick) |
| Connection type | Safety shockproof connector / QUIK-COMBO clip type (depending on equipment model) |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from date of manufacture (expiry on packaging) |
| Storage / operation | Dry place between +5 °C and +35 °C; operating range 0 °C to +50 °C |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium bag; 10 pairs per box (adult series) |
3.2 Compatibility with defibrillators
| Equipment brand | Compatible models |
| Physio-Control / Stryker | LIFEPAK 9 (with QUIK-COMBO adapter), LIFEPAK 10, LIFEPAK 12, LIFEPAK 15 and LIFEPAK 20 |
| Cardioline | ELIFE 700 |
| Mindray | BeneHeart D1 (Public / Pro), BeneHeart D3 and BeneHeart D6 |
Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.
4. Equivalences and Cross-References
Reference F7752 is a consumable compatible with the cited defibrillators, not an original replacement certified by each equipment manufacturer: the connector, analysis algorithm and energy management are proprietary. After verifying official manufacturer catalogues, authorised technical distribution and regulatory databases (GUDID), the following cross-references with code confirmed in public sources are identified. Any comparison between brands must be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Stryker / Physio-Control | EDGE System RTS (Radiotransparent) Electrodes with QUIK-COMBO Connector | 11996-000090 (alternative 3010188-009) | Comparable by category (not interchangeable 1:1) | Factory original radiotransparent for LIFEPAK 12, 15, 20 and 20E; QUIK-COMBO connector and same clinical function. Code confirmed in official Stryker store, authorised distribution and GUDID (UDI 00721902195037). Cable 0.6 m inside the packaging (similar internal cable configuration); gel, labelling and packaging proprietary to Stryker. |
| Stryker / Physio-Control | EDGE System Electrodes with QUIK-COMBO Connector (standard, leads-in) | 11996-000091 | Comparable by category (not interchangeable 1:1) | Original for LIFEPAK 12, 15 and 20; cable inside the packaging (not pre-connected). Code verified in GUDID/FDA (UDI 00883873784945). Non-radiotransparent version: differs from this reference in the imaging requirement. |
| Mindray | MR60 – Adult Multifunction Electrode Pads (BeneHeart) | 115-040517-00 | Comparable by category (not interchangeable 1:1) | Original Mindray for BeneHeart D1, D3, D6 and C series; adult >25 kg, up to 50 shocks at 360 J and radiolucent. Code confirmed in the official Mindray pads guide and authorised distribution. Connector and algorithm proprietary to Mindray. |
| Bexen Cardio | Original adult electrodes for Reanibex 200/300/500/700/800 (not pre-connected) | TKL0311A | Comparable by category (not interchangeable 1:1) | Factory original replacement for the REANIBEX series, of the same QUIK-COMBO connection platform; non-pre-connected presentation (internal cable). Code confirmed in authorised distribution. |
| Leonhard Lang | Skintact® Easibeat – adult multifunction electrode, Physio-Control platform | DF20N | Comparable by category (not interchangeable 1:1) | Multifunction (defibrillation, pacing, cardioversion and monitoring) for LIFEPAK 9, 10, 12, 15, 20 and 500; 1 pair per pouch and 10 pouches per box. Code confirmed in official Leonhard Lang documentation and authorised distribution. Connector, gel and materials proprietary; verify fit before replacement. |
| Cardioline | Single-use defibrillation electrode (2 pcs) for ELIFE 700 | 8730420 | Comparable by category (not interchangeable 1:1) | Factory original replacement for the Cardioline ELIFE 700 defibrillator; presentation per pair. Code confirmed in authorised distribution. Verify connector and energy management of the device before replacement. |
There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes of these devices with third-party pads: the connector, analysis algorithm and energy management are proprietary to each defibrillator. Any replacement must be validated against the device’s technical data sheet and IFU; consult the technical department of Cahnos before using in a tender.
5. Selection tips and variants of interest
Confirm the model and connector of your device: this pair corresponds to Physio-Control LIFEPAK 9 (with QUIK-COMBO adapter), 10, 12, 15 and 20 defibrillators and monitors, as well as Cardioline ELIFE 700 and Mindray BeneHeart D1/D3/D6. Always verify the connector fit and the expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention: the gel may lose conductivity and compromise the effectiveness of the shock.
Choose the variant according to your workflow: the internal cable of this model (F7752) provides a clean and robust connection during resuscitation; if you prefer to leave the device pre-connected and ready in seconds, you have the radiotransparent version with external cable of the same series (F7752W). For standard use without radiotransparency requirement, consider the adult versions F7952 (internal cable) or F7952W (external cable), at lower cost. If attending to paediatric population (under 8 years or 25 kg), use the radiotransparent paediatric references F7752P and F7752PW.
Storage and stock: store in a dry place between +5 °C and +35 °C and respect the expiry date on the packaging (approximate shelf life of 30 months). As it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For volume orders or tenders, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your devices; we will confirm compatibility before finalising the order.