We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Pair of adult defibrillator electrodes, radiotransparent, with external cable (pre-connected) — Compatible replacement for ZOLL Medical PD 1200–PD 2000, E/M/R Series and AED M&D AED 7000 — Ref. F7751W

34,98 €

Pair of adult defibrillator electrodes, radiotransparent, with external cable (Ref. F7751W), single-use replacement compatible with ZOLL Medical defibrillators and monitors PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series, as well as with the AED M&D AED 7000. Disposable multifunction pads for defibrillation, synchronised cardioversion, transcutaneous pacing and ECG monitoring, with low-impedance conductive adhesive gel on medical foam and metal foil: active surface area of 94 cm² per electrode and up to 50 discharges at 360 J. Their radiotransparent construction (electrode and cable) allows imaging control in X-ray and CT without artefacts, and the external cable leaves the equipment pre-connected and ready in an emergency. Latex-free and phthalate-free, class IIb medical device.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7751W

Description

1. Commercial Introduction

Keep your ZOLL defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with external cable (Ref. F7751W), a high-reliability replacement compatible with ZOLL Medical equipment from the PD, E, M and R series, as well as with the M&D AED 7000 AED. Designed for emergency departments, ICUs, patient transport, operating theatres and cardio-protected sites, it simplifies consumables management: thanks to its external cable (pre-connected) configuration, you can connect the pads to the device in seconds, without opening or handling the packaging at the critical moment, and leave the patient’s chest visible for radiological imaging without interference. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

These pads are single-use disposable multifunction electrodes: through them the defibrillator analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency ECG monitoring. The low-impedance conductive adhesive gel guarantees homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest.

Being radiotransparent —electrode and cable—, they do not generate artefacts in fluoroscopy, tomography or intraoperative monitoring, allowing the healthcare team to assess the rib cage, pacemaker or vascular access without removing the pads. The external cable variant leaves the connector accessible outside the bag: the pad remains pre-connected and ready for the emergency, reducing preparation time. The condition of use is single-patient: after resuscitation they must be disposed of and replaced, always respecting the expiry date printed on the packaging. The recommended placement is anterolateral (sternum-apex), according to the anatomical diagrams on the pouch.

3. Technical specifications and compatibility

3.1 Technical specifications

Main features of the series of adult radiotransparent electrodes with external cable to which this reference belongs:

Parameter Specification
Reference Cahnos (SKU) F7751W
Compatible brand ZOLL Medical (proprietary connector) and M&D
Product type Pair of adult multifunction radiotransparent defibrillator electrodes, with external cable (preconnected)
Patient type Adult (older than 8 years / more than 25 kg)
Radiotransparency Yes (electrode and cable), suitable for imaging procedures
Cable configuration External cable: connector and cable outside the bag, immediate connection (preconnected)
Functions Defibrillation, synchronized cardioversion, transcutaneous pacing (pacemaker) and ECG monitoring
Total surface per electrode 136 cm²
Active surface per electrode 94 cm²
Adhesive ring width 0.7 cm
Supported shocks Up to 50 shocks at 360 J
ECG monitoring Max. 24 h
Conductive gel Low-impedance conductive adhesive gel
Backing material Medical foam (1 mm) with conductive metal foil
Connector Specific connector for ZOLL equipment (verify correct fit in the device socket)
Use Single-use, disposable; non-sterile; latex-free and phthalate-free
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box
Shelf life Approx. 30 months from date of manufacture (check printed expiry date)
Conditions of use and storage Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C
Classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Note: the values for active surface (94 cm²), total area (136 cm²), shocks (50 to 360 J) and adhesive ring (0.7 cm) correspond to the series of adult radiotransparent electrodes with external cable in this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tenders.

3.2 Compatibility with defibrillators

Equipment brand Compatible models
ZOLL Medical PD 1200, PD 1400, PD 1600, PD 1700, PD 2000
ZOLL Medical E Series, M Series, R Series
M&D AED 7000

Note: according to the manufacturer’s documentation for the original ZOLL electrodes, manual mode must be used for energy adjustment with M Series, E Series and R Series equipment. Compatibility refers to the connector platform of each family; always verify the correct fit of the connector and cable of your equipment before clinical use.

4. Equivalences and Cross-References

Reference F7751W is a consumable compatible with the cited defibrillators, not an original spare part certified by the equipment manufacturer: the connector, analysis algorithm and energy management are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID), the following cross-references with codes confirmed in public sources have been identified. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
ZOLL Medical Radiotransparent Defibrillation Electrode, adult (original equipment) 8900-004041-01 (preconnected: 8900-004045-01) Comparable by category (not interchangeable 1:1) Factory original radiotransparent multifunction for ZOLL R Series and X Series equipment; code confirmed in the official ZOLL store and authorised distribution. Pre-connected cable (lead-out) in the corresponding variant, proprietary connector of the same platform; verify fit before replacement.
ZOLL Medical Stat-Padz® II — adult multifunction electrodes (original equipment) 8900-0802-01 Comparable by category (not interchangeable 1:1) Factory original for ZOLL AED Plus / AED Pro / AED 3 and M, E, R and X Series equipment; code confirmed in the official ZOLL store and GUDID. It is not radiotransparent and the cable is inside the packaging; polymer gel, labelling and packaging proprietary to ZOLL.
CONMED PadPro® RTS — adult multifunction radiotransparent electrode, ZOLL connector 2001Z (pre-connected: 2001Z-PC) Comparable by category (not interchangeable 1:1) Code confirmed in authorised European and American technical distribution: adult radiotransparent with ZOLL connector, up to 50 shocks / 8 h of continuous pacing / 24 h of monitoring, 36 months of service life. Geometry, gel and labelling proprietary to CONMED; same ZOLL connector platform as this reference. Verify fit before replacement.
Leonhard Lang Skintact® Easibeat — adult multifunction electrode, ZOLL connector DF28N (pre-connected: DF28NC) Comparable by category (not interchangeable 1:1) Code confirmed in the official Leonhard Lang catalogue: multifunction (defibrillation, pacing, cardioversion and monitoring) for ZOLL E Series, M Series, R Series, PD 1200, PD 1400, PD 1600, PD 1700 and PD 2000; 1 pair/pack, 10 packs/case. Connector, gel and materials proprietary; verify the radiotransparent nature of the specific variant and connector fit before replacement.

For the M&D AED 7000 platform, no verifiable original electrode code has been found in public sources, so its equivalents remain pending confirmation with the manufacturer. There is no manufacturer-validated equivalence table authorising the replacement of original electrodes with third-party pads: the connector, analysis algorithm and energy management of each defibrillator are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department at Cahnos before use in tenders.

5. Selection tips and variants of interest

Confirm the model and connector of your equipment: this pair corresponds to ZOLL defibrillators and monitors PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series, as well as to the M&D AED 7000 AED. Verify the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after a procedure.

Choose the variant according to your workflow: the external cable of this model allows the equipment to be pre-connected and ready in seconds; if you prefer a direct connection without a loose cable, the reference F7751 is available (same adult radiotransparent series with internal cable). For standard use without radiotransparency requirement, consider F7951W (standard adult with external cable), at a lower cost. If you treat paediatric patients, the radiotransparent paediatric references F7751P (internal cable) and F7751PW (external cable) are available.

Storage and expiry: store in a dry place between +5 °C and +35 °C and observe the expiry date on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO).

Other platforms in the category: for defibrillators from other manufacturers with the same radiotransparent configuration with external cable, the following are available: F7750W (Philips), F7752W (Physio-Control / Bexen / Mindray), F7755W (Nihon Kohden / Welch Allyn / Dräger) and F7760W (Metrax Primedic); these are not interchangeable due to proprietary connectors. For volume orders or tenders, contact the technical department of Cahnos, indicating the exact model and serial number of your equipment.

Additional information

Product type

Pair of adult multifunction radiotransparent defibrillator electrodes, external cable (lead-out / preconnected)

Compatibility

ZOLL PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series, R Series; M&D AED 7000

Population

Adult (older than 8 years / more than 25 kg)

Cable

External (preconnected / lead-out)

Connector

Specific connector for ZOLL equipment (verify fit)

Radiotransparency

Yes (electrode and cable), for artefact-free imaging

Total area

136 cm² per electrode

Active area

94 cm² per electrode

Adhesive ring width

0.7 cm

Supported shocks

Up to 50 shocks at 360 J

ECG monitoring

Max. 24 h

Functions

Defibrillation, synchronized cardioversion, transcutaneous pacing (pacemaker) and ECG monitoring

Conductive gel

Low-impedance conductive adhesive gel

Backing material

Medical foam (1 mm) with conductive metal foil

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box

Use

Single-use, disposable; non-sterile; latex-free and phthalate-free

Shelf life

Approx. 30 months from date of manufacture (check printed expiry date)

Classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Storage

Dry place between +5 °C and +35 °C; operating range 0 °C to +50 °C

Reference

F7751W

Type

Pair of adult multifunction radiotransparent defibrillator electrodes with external cable (preconnected)

Radiolucent

Yes (electrode and cable)

Adhesive ring

0.7 cm

Material

Medical foam (1 mm) with conductive metal foil

Reviews

There are no reviews yet.

Be the first to review “Pair of adult defibrillator electrodes, radiotransparent, with external cable (pre-connected) — Compatible replacement for ZOLL Medical PD 1200–PD 2000, E/M/R Series and AED M&D AED 7000 — Ref. F7751W”

Your email address will not be published. Required fields are marked *