Description
1. Commercial Introduction
Keep your Philips defibrillator always operational with this pair of adult radiotransparent defibrillation electrodes with internal cable (reference Cahnos F7750), a high-reliability consumable compatible with the most widespread families of AEDs and monitor-defibrillators from Philips: Heartstream ForeRunner AED (E, S, EM), HeartStart FR AED, FR2 and FR2+, CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart 4000 (M5500B), XL/XLT, MRx, Efficia DFM100 and HeartStart Intrepid. Designed for emergency services, ICUs, ambulances, operating theatres, haemodynamics and cardioprotected spaces, it combines the advantages of the radiotransparent series —image control without artefacts— with the robustness of the integrated internal cable connection, which avoids loose cables during resuscitation. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion, non-invasive transcutaneous pacing (external pacemaker) and emergency ECG monitoring. This adult model (patients over 8 years of age or weighing more than 25 kg) is constructed with low-impedance conductive adhesive gel, which ensures homogeneous contact with the skin and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest.
Its radiotransparent condition —in the electrode and in the cable— prevents artefacts in radiography, radioscopy and tomography, so the pads can be kept in place during imaging examinations without interrupting monitoring or therapy. The integrated internal cable configuration (leads-in) provides a stable and direct connection to the device socket. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging, being placed in the anterolateral position (sternum-apex) according to the anatomical diagrams on the pouch.
3. Technical specifications and compatibility
3.1 Technical specifications
Main features of the series of adult radiotransparent electrodes with internal cable to which this reference belongs:
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7750 |
| Product type | Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Cable configuration | Integrated internal cable (leads-in), 100 cm |
| Total surface per electrode | 136 cm² (adult series) |
| Active surface per electrode | 94 cm² (adult series) |
| Adhesive ring width | 0.7 cm |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector compatible with Philips equipment |
| Functions | External defibrillation, synchronized cardioversion, transcutaneous pacing and ECG monitoring |
| ECG monitoring | Up to 24 hours |
| Supported shocks | Up to 50 shocks at 360 J |
| Composition | Latex-free and phthalate-free · Single-use |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium bag |
| Sales format | 10 pairs per box (adult series) |
| Shelf life | Approx. 30 months from production date (see expiry on the packaging) |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
| Regulatory classification | Medical device class IIb (EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Note: the values for active surface area (94 cm²), total area (136 cm²), discharges (50 to 360 J) and adhesive ring (0.7 cm) correspond to the series of adult radiotransparent electrodes with internal cable in this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tenders.
3.2 Compatibility with defibrillators
| Family / Equipment model | Factory reference | Observations |
|---|---|---|
| Heartstream ForeRunner AED (E, S, EM) | — | Direct connection of the pads |
| HeartStart FR AED / FR2 / FR2+ | FR2: M3840A, M3841A · FR2+: M3860A, M3861A | Direct connection; on FR3 do not leave connected in standby or off |
| CodeMaster 100 | M2475B | Direct connection / with hands-free cable M3507A |
| CodeMaster XE | M1724A | Direct connection |
| CodeMaster XL / XL+ | M1723A/B · M1722A/B | Direct connection |
| HeartStart 4000 | M5500B | Energy in manual adjustment |
| HeartStream / HeartStart XL | M4735A | Requires hands-free electrode cable M3508A |
| HeartStream / HeartStart XLT | M3500B | Requires hands-free electrode cable M3508A |
| HeartStart MRx | M3535A / M3536A | Requires cable M3508A; do not use in fully automatic mode |
| Efficia DFM100 / HeartStart Intrepid | — | Direct connection |
Technical note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.
4. Equivalences and Cross-References
Reference F7750 is a consumable compatible with the cited Philips defibrillators, not an original spare part certified by the device manufacturer: the connector, analysis algorithm and energy management are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID), the following cross-references with codes confirmed in public sources have been identified. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips Healthcare | Adult Multifunction Pads, IEC barrel connector (original equipment) | M3502A (alternative code 989803106931) | Comparable by category (not interchangeable 1:1) | Factory original for the CodeMaster 100 (M2475B), XE (M1724A), XL/XL+ (M1723A/B, M1722A/B), HeartStart 4000 (M5500B), XL (M4735A), XLT (M3500B) and MRx (M3535A/M3536A) families. Code confirmed in authorised technical distribution. It is not radiotransparent (standard version); verify connector, surface and cable before replacement. |
| Philips Healthcare | HeartStart Adult Defibrillator Pads (AED FR2/FR2+ / ForeRunner) | 989803158211 (1 pair) / 989803158221 (5 pairs) | Comparable by category (not interchangeable 1:1) | Original for the AEDs of the HeartStart FR2/FR2+ and ForeRunner family, indicated for patients ≥8 years or ≥25 kg; code confirmed on the official Philips website and in GUDID (DI 00884838023710 / 00884838126299). Not radiotransparent; connector and algorithm proprietary to the same AED platform. |
| Cardinal Health (Medi-Trace™ Cadence) | Adult Multi-Function Defibrillation Electrodes, Radiotransparent, Philips barrel connector | 22661R (preconnected: 22661PC) | Comparable by category (not interchangeable 1:1) | Adult radiotransparent pair with barrel connector compatible with the Philips/Agilent-HP family (HeartStream/HeartStart XL, XL+, MRx and CodeMaster); silver/silver chloride gradient technology and 10 pairs per box. Code confirmed in GUDID (DI 20884527022370) and manufacturer catalogue. Verify connector and surfaces before replacement. |
| Nissha Medical Technologies (HeartSync) | 97-DEFIB F/G C100AC-PHILIPS (D311) | 6600015H (ref. C100AC-PHILIPS) | Comparable by category (not interchangeable 1:1) | Adult radiotransparent pair with internal cable (leads-in) and connector comparable to the original Philips; total surface area of 371 cm², carbon conductive element, 1.5 m cable and 36 months of service life. Code confirmed in the manufacturer’s official catalogue. Not suitable for all models: verify connector and compatibility with the exact device. |
There is no equivalence table validated by the manufacturer that authorises the replacement of original Philips electrodes with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator, checking one by one the device connector, energy range, target population and packaging expiry date. Consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Confirm the model and connector of the device: verify on the defibrillator plate the exact model (ForeRunner AED, FR AED/FR2/FR2+, CodeMaster 100/XE/XL/XL+, HeartStart 4000, XL/XLT, MRx, Efficia DFM100 or Intrepid) and check the required therapy cable (M3507A / M3508A / 989803197111 on models that require it) before storing the spare part.
- Operating mode: on HeartStart 4000, XL/XLT and MRx the energy is adjusted manually; do not use this electrode in fully automatic defibrillators. On FR3 equipment do not leave the electrodes connected in standby or powered off and, for patients under 25 kg, use the child/neonate key REF 989803150031.
- Choose radiolucent when imaging tests are anticipated: if the patient may require X-ray, fluoroscopy or CT scan during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard non-radiolucent version of the same platform (F7950), at lower cost, may be considered.
- Variants of the same family at Cahnos: radiolucent version with external cable (F7750W) if you prefer the pre-connected pair ready for emergencies; paediatric radiolucent version with internal cable (F7750P) for patients under 8 years or 25 kg. For other platforms in the radiolucent internal cable category, you have F7751 (ZOLL), F7752 (Physio-Control/Mindray), F7755 (Nihon Kohden/Welch Allyn) and F7756 (Schiller FRED easy), not interchangeable with each other due to proprietary connector.
- Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date on the package; the conductive gel may dry out and reduce its conductivity after the expiry date. As it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO).
- Institutional orders: for consortia, tenders or fleet maintenance, contact the technical-commercial department of Cahnos indicating the exact model and serial number of your equipment; we will confirm compatibility before formalising the order.