1. Commercial Introduction
Keep your defibrillator always operational with this pair of adult radiotransparent defibrillator electrodes with internal cable (reference Cahnos F7754), a high-reliability replacement compatible with Schiller classic generation defibrillators and monitors (FRED, FRED TELE, Defigard DG 1002, DG 3002 and DG 2000 EDOS) and with Esaote equipment (MDF SAED and MDF II). Designed for emergency departments, ICUs, ambulances, operating theatres and cardioprotected centres, it simplifies consumables management with a single reference for the most widespread Schiller and Esaote fleets. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector before placing the order.
2. Technical Explanation
Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock, enables synchronised cardioversion, non-invasive transcutaneous pacing and emergency ECG monitoring. In this adult model, the low-impedance conductive adhesive gel ensures homogeneous skin contact, low interface resistance and optimal transmission of the shock energy; the internal metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest.
Its radiotransparent condition —electrode and cable— avoids artefacts in radioscopy, tomography and intraoperative monitoring, so that the healthcare team can assess the rib cage, pacemaker or vascular accesses without removing the patches. The variant with internal cable keeps the connector protected inside the packaging until the moment of use, ensuring a clean and stable connection throughout the resuscitation. The patches are placed according to the anatomical diagrams on the envelope (sternal and apical position) and are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Adult radiotransparent multifunction electrode from the internal cable series, compatible with Schiller classic generation defibrillator fleets and Esaote.
| Parameter | Specification |
| Reference Cahnos (SKU) | F7754 |
| Product type | Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable |
| Indicated population | Adult: over 8 years old or weighing more than 25 kg |
| Radiotransparency | Yes (electrode and cable), for artefact-free imaging |
| Cable configuration | Internal cable integrated into the package; direct connection after opening |
| Total surface per electrode | 136 cm² |
| Active surface per electrode | 94 cm² |
| Adhesive ring width | 0.7 cm |
| Supported shocks | Up to 50 shocks at 360 J |
| ECG monitoring | Up to 24 hours |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector |
| Use | Single-use, disposable; latex-free and phthalate-free |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box |
| Shelf life | Approx. 30 months from date of manufacture (expiry on packaging) |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993 |
3.1 Compatibility with defibrillators
| Equipment brand | Compatible models |
| Schiller | FRED, FRED TELE, Defigard DG 1002, Defigard DG 3002, Defigard DG 2000 EDOS |
| Esaote | MDF SAED, MDF II |
Technical note: this electrode corresponds to the classic connection generation for manual devices with energy adjustment according to protocol; in automatic or semi-automatic models, the energy must be adjusted according to the defibrillator manual. Always verify the correct insertion of the connector before clinical use.
4. Equivalences and Cross-References
Reference F7754 is a consumable compatible with the cited Schiller and Esaote equipment, not an original factory spare part. The correspondence with manufacturer references is detailed below; any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Schiller | Original adult electrodes for FRED easy and Defigard DG 4000/5000/6002 | 0-21-0037 / 2.230347 | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution sources and manufacturer documentation; corresponds to the FRED easy / Defigard DG 4000-6002 series, with connector and generation different from the classic FRED and Defigard DG 1002/3002 equipment of this reference. Radiotransparency of the original has not been confirmed in public sources. Verify connector, dimensions and characteristics before replacement. |
| GIMA | Replacement pad compatible with Esaote/Schiller equipment (standard version) | F7954 | Comparable by category (not interchangeable 1:1) | Code published in the manufacturer’s catalogue as a pad compatible with this equipment, in standard non-radiotransparent version; same equipment platform but without the imaging properties of this reference. Verify connector and energy management before replacement. |
For the equipment family covered by this reference (FRED, FRED TELE, Defigard DG 1002, DG 3002, DG 2000 EDOS and Esaote MDF SAED / MDF II) no original Schiller or Esaote code with a complete product description has been found in public sources. There is no equivalence table validated by the manufacturer authorising the replacement of original electrodes by third-party patches: the connector and energy management are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and instructions for use; consult with the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Select according to the patient: this adult reference is for over 8 years old or weighing more than 25 kg. For paediatric patients (under 8 years / less than 25 kg) use the paediatric version of the same radiotransparent family with internal cable (F7754P) or the standard version (F7954P).
- Choose radiotransparent when imaging tests are anticipated: if the patient may require X-ray, radioscopy or CT scan during care, this version avoids artefacts without removing the electrode. If imaging is not required, the standard version with internal cable (F7954) may be considered, at a lower cost, with the same equipment compatibility.
- Check the equipment generation: the Schiller FRED easy, Defigard DG 4000/5000/6002 and easyport models use a different connector and require the F7756 (adult) / F7756P (paediatric) family; always check the connector fit before storing the spare part. This reference F7754 is not interchangeable with other platforms in the category (Philips, ZOLL, Physio-Control, Nihon Kohden) due to the proprietary connector.
- Storage and expiry: store in a dry place between +5 °C and +35 °C and respect the expiry date printed on the packaging; the conductive gel may dry out and reduce its conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO).