Description
1. Commercial Introduction
Keep your Nihon Kohden defibrillator-monitor always operational with this pair of adult radiotransparent defibrillator electrodes with internal cable (reference Cahnos F7761), a replacement from the radiotransparent series designed for the Cardiolife TEC-2200, TEC-2300, TEC-5500 and TEC-5600 series with JC-765V cable. It is the ideal solution for hospital emergency departments, intensive care units, ambulances, operating theatres, haemodynamics rooms and any facility with a professional defibrillator in service: a single pair of disposable pads keeps the equipment ready to act in cardiorespiratory arrest. Available with immediate delivery from Cahnos and specialised technical support to verify compatibility by model and connector.
2. Technical explanation of the equipment and procedure
Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and monitors the emergency electrocardiogram. This adult model enables external transthoracic defibrillation, synchronised cardioversion, non-invasive transcutaneous cardiac pacing and ECG monitoring.
The configuration with integrated internal cable provides a direct and stable connection to the device’s electrode socket via the JC-765V cable, without loose cables during resuscitation. As they are radiotransparent, the electrode and its cable do not generate artefacts in fluoroscopy, tomography or intraoperative monitoring, allowing the rib cage, pacemaker or vascular access to be assessed without removing the pads. The low-impedance conductive adhesive gel ensures homogeneous contact with the skin and optimal energy transmission; the metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the adult chest. They are single-patient use: after resuscitation they must be disposed of, respecting the expiry date printed on the packaging.
3. Technical Specifications
Main features of the adult radiotransparent electrode series with internal cable to which this reference belongs (Ref. Cahnos F7761):
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7761 |
| Product type | Pair of adult multifunction defibrillator electrodes, radiotransparent, with internal cable |
| Compatible brand | Nihon Kohden (proprietary connector) |
| Compatible models | Cardiolife TEC-2200, TEC-2300, TEC-5500 and TEC-5600 series |
| Cable / connection | Internal JC-765V cable (direct connection to the device’s electrode socket) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Radiotransparency | Yes (electrode and cable), suitable for imaging procedures |
| Functions | External defibrillation, synchronized cardioversion, non-invasive transcutaneous pacing and ECG monitoring |
| Supported shocks | 50 shocks up to 360 J (adult series) |
| ECG monitoring | Max. 24 h |
| Adhesive ring width | 1 cm |
| Total / active area (per electrode) | 148 cm² total / 95 cm² active* |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | 1 mm thick medical foam |
| Connection type | Safety anti-shock connector / clip, with internal cable |
| Use | Single-use, disposable, non-sterile; free from latex and phthalates |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 10 pairs per box |
| Operating temperature | Between 0 °C and +50 °C |
| Storage | Dry place, between +5 °C and +35 °C |
| Shelf life | 30 months from the date of manufacture (expiry date indicated on the packaging) |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10 |
*Values for the adult series of this electrode family; confirm with the technical data sheet of the supplied batch and with the equipment manual before use in tendering.
3.1 Compatibility with defibrillators
| Equipment brand | Compatible models | Cable / connection |
|---|---|---|
| Nihon Kohden | Cardiolife TEC-2200 Series | Internal cable JC-765V |
| Nihon Kohden | Cardiolife TEC-2300 Series | Internal cable JC-765V |
| Nihon Kohden | Cardiolife TEC-5500 Series | Internal cable JC-765V |
| Nihon Kohden | Cardiolife TEC-5600 Series | Internal cable JC-765V |
Always verify the correct fit of the connector in the equipment’s electrode socket before clinical use.
4. Equivalences and Cross-References
Reference F7761 is the Cahnos distribution code for this adult radiotransparent electrode compatible with Nihon Kohden; it is not an official reference of the equipment manufacturer. The connector and energy management of the Cardiolife TEC defibrillators are proprietary to Nihon Kohden, so equivalences with other brands are comparable only at category level and are not 1:1 interchangeable. The following cross-references have a confirmed code in the manufacturer’s IFU, official catalogues or data sheets from authorised technical manufacturer-distributor:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Nihon Kohden | Disposable adult/child/infant pad (original equipment) | P-740K | Comparable by category (not interchangeable 1:1) | Factory original with 1.5 m cable; reference confirmed in official IFU and authorised distributors. Covers AED and TEC-5500/5600/7600/7700/8300 families; not verified for the TEC-2200/2300 series with internal JC-765V cable. Connector and labelling proprietary to Nihon Kohden. |
| Nihon Kohden | Disposable AED electrodes adult/child/infant (original equipment) | P-711 (order code H329) | Comparable by category (not interchangeable 1:1) | Factory original with 1.5 m cable for adult, child and infant; confirmed in authorised distributors. Aimed at the Cardiolife AED and TEC-8300K families; not verified for the TEC-2200/2300/5500 series with JC-765V cable. |
| AB Medica Group (Lessa) | Adult radiotransparent defibrillation pads for TEC-2200 with JC-765V cable | 99.835.66 | Comparable by category (not interchangeable 1:1) | Same functional profile: adult radiotransparent electrode for the TEC-2200 platform with JC-765V cable. Code confirmed in the manufacturer-distributor data sheet; connector and shock protocol proprietary to the equipment. |
| AB Medica Group (Lessa) | Adult defibrillation pads for TEC-2300 with JC-765V cable | 99.835.22 | Comparable by category (not interchangeable 1:1) | Covers the adult TEC-2300 platform with JC-765V cable; the public data sheet does not confirm radiotransparency, so it is not 1:1 interchangeable with this reference in imaging procedures. Code confirmed in the manufacturer-distributor data sheet. |
| Nissha Medical Technologies (HeartSync) | Defibrillation pads compatible with Nihon Kohden TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 | T100AC-NIHONKOHDEN (ref. 6600265H) | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: connector comparable to the original Nihon Kohden and cable included in the packaging. Catalogued adult version; verify radiotransparency, connector and cable (JC-765V / JC-755V / K342A depending on series) before replacement. |
There is no equivalence table validated by the manufacturer (Nihon Kohden) that authorises the replacement of the original electrodes with third-party pads: the connector, the analysis algorithm and the energy management of each defibrillator are proprietary and are not interchangeable 1:1 between brands. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Confirm the model and connector of the device: this pair corresponds to the Nihon Kohden Cardiolife TEC-2200, TEC-2300, TEC-5500 and TEC-5600 defibrillators with internal cable JC-765V. Check the connector fits into the electrode socket before clinical use and, if in doubt, contact the technical department of Cahnos stating the model and serial number.
- Do not confuse the adult and paediatric versions: this pair is for patients over 8 years old or over 25 kg. For the paediatric population of the same connector family, the reference F7961P is available (standard paediatric with internal cable, Nihon Kohden).
- Variants of the same family at Cahnos: if you do not need radiotransparency, for the same Nihon Kohden platform with internal cable you have reference F7961 (standard adult) or F7961W (standard with external cable); for the Marquette GE/Esaote platform of the same radiotransparent category with internal cable, reference F7762 is available. Always verify which connector family corresponds to each device.
- Storage and expiry: check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with damaged packaging, as the gel may lose conductivity. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to expiry.
- Institutional orders: for consortia, tenders or fleet maintenance, contact our technical-commercial department stating the exact models of your equipment; we will confirm compatibility before formalising the order.





Reviews