Description
1. Commercial Introduction
Keep your automated external defibrillator always ready to act with this pair of adult defibrillation electrodes, disposable and original (Ref. 35344 – SKU GM35344), designed for CU Medical Systems i-PAD equipment of models CU-SP1 and CU-SP2, as well as for the defibrillator Ref. 35340/1. This is the replacement consumable indicated for emergency services, ambulances, sports centres, companies and any cardioprotected space equipped with these AEDs: single-use electrodes that guarantee an immediate and safe response in the resuscitation of adult patients. Sold as a pair (kit of 2 units), ready to integrate into your cardiopulmonary resuscitation protocols.
2. Technical explanation of the equipment and procedure
Multifunction electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm (ventricular fibrillation and ventricular tachycardia), delivers the transthoracic shock and allows emergency ECG monitoring. This pair is indicated for adult patients and is manufactured with low-impedance conductive adhesive gel, which ensures homogeneous contact with the skin, low interface resistance and optimal transmission of shock energy during assistance. These are single-use disposable electrodes: they must not be reused and must be replaced after each intervention or upon reaching the expiry date printed on the packaging. The recommended placement follows the anatomical diagrams on the pouch (anterolateral position, sternum-apex).
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer reference | 35344 |
| Reference Cahnos (SKU) | GM35344 |
| Product type | Pair of adult defibrillator electrodes, disposable, original («ORIGINAL PADS») |
| Patient type | Adult |
| Presentation | 1 pair (2 electrodes) / kit of 2 pcs |
| Compatible equipment brand | CU Medical System |
| Compatible models | CU-SP1, CU-SP2 (AED i-PAD) |
| Associated equipment | 35340/1 |
| Use | Single-use, disposable |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | kit of 2 pcs |
| Device type | Medical device |
| Device class | II B |
| CND | C020501 |
| GMDN | 44771 |
| EAN | 8809435481031 |
Compatibility note: confirm the exact model of your equipment (CU-SP1 or CU-SP2, or the defibrillator Ref. 35340/1) and the connector fit before clinical use. Electrodes from other CU Medical AEDs (Paramedic CU-ER series, i-PAD NF1200/NF1201 or NFK200) are not interchangeable with those from the i-PAD SP1/SP2 series, as they use their own connectors and consumables.
4. Equivalences and Cross-References
The pair of electrodes Ref. 35344 is declared by the manufacturer for CU Medical System defibrillators of models CU-SP1 and CU-SP2 (AED i-PAD) and for equipment Ref. 35340/1, expressly indicating the compatible equipment brand (CU Medical System). CU Medical Systems does not publish an official equivalence table authorising the replacement of its AEDs’ original consumables with patches from other manufacturers: the connector, analysis algorithm and energy management are proprietary. Any comparison with electrodes from other platforms should be understood as comparable at category level, never interchangeable 1:1, verifying connector, energy range and equipment model before any replacement. Within the Cahnos catalogue there are multifunction electrodes from the same product family for other CU Medical AEDs (for example, for i-PAD NF1200/NF1201), which are not compatible with the i-PAD SP1/SP2 series; consult the Cahnos technical department before use in tenders.
5. Selection tips and variants of interest
- Confirm the equipment model: this pair corresponds to CU Medical Systems i-PAD CU-SP1 and CU-SP2 AEDs and to the defibrillator Ref. 35340/1. Verify the connector fit and the reference before formalising the replacement.
- Check the expiry date: always check the date printed on the packaging and do not use expired electrodes or those with an open or damaged pouch: the gel may lose conductivity and compromise the shock.
- Single-use consumable: replace the pair immediately after each actual use and always keep a spare set next to the defibrillator to avoid leaving the equipment out of service.
- Storage: store the electrodes in a dry place, at room temperature, and rotate stock by expiry date (FIFO).
- Adult use: this pair is indicated for adult patients; for paediatric care consult the manufacturer’s paediatric variants for the equipment.
- Institutional orders: for specifications, tenders or continuous supply contracts, contact the technical-commercial department of Cahnos indicating the exact defibrillator model and required quantities.