Triglyceride Control Solution for MULTICAREIN Analysers (Ref. GM23980) | IVD Quality Control for 23147/8/9, 23965/66/67 and 24150/51/52

54,15 €

Original triglyceride control solution (ref. 23980) for the periodic verification of the multiparametric analysers MULTICAREIN of the 23147/8/9, 23965/66/67 and 24150/51/52 series. This in vitro diagnostic reagent (IVD – Self Test) allows you to check that the device’s triglyceride channel, test strips and measurement procedure work within the expected ranges, ensuring reliable and traceable results in self-monitoring of the lipid profile. Single presentation (1 pc), indicated for pharmacies, orthopaedic shops, clinics and cardiovascular prevention programmes. By Cahnos; consult conditions with your technical-commercial advisor. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23980

Description

1. Commercial Introduction

The triglyceride control solution (ref. 23980) is the essential verification reagent for keeping your multiparametric analyser MULTICAREIN in the best performance conditions. It is part of the control solutions system and is specifically designed for the equipment of the 23147/8/9, 23965/66/67 and 24150/51/52 series. With it you can easily, quickly and reliably validate the triglyceride channel of your device, both in the professional setting (pharmacies, orthopaedic shops, clinics and health centres) and in self-monitoring and cardiovascular prevention programmes.

2. Technical Explanation

Control solutions allow you to check that the meter, test strips and analysis procedure work within the expected ranges. This triglyceride control solution is applied to the specific test strips of the MULTICAREIN system and the result must fall within the range printed on the packaging and reflected by the meter; if not, it is recommended to repeat the test and, if the deviation persists, to check the device or the batch of strips. The product is classified as an in vitro diagnostic self-test device (IVD – Self Test), which enables it to be used by the end user themselves without the need for healthcare personnel. Its periodic use, especially when opening a new batch of test strips, reinforces the traceability and confidence of each analytical result.

3. Technical Specifications

We fully preserve the technical data recorded in the manufacturer’s catalogue:

Value Value
Manufacturer GIMA
Manufacturer reference 23980 (SKU Cahnos: GM23980)
Control parameter Triglycerides
Sales unit 1 pc
Device type IVD – Self Test
CND W0101059099
EAN 8032937230443

Verified compatibility:

Compatible equipment Description
MULTICAREIN 23147/8/9 Multiparametric analysers of the 23147/48/49 series
MULTICAREIN 23965/66/67 Multiparametric analysers of the 23965/66/67 series
MULTICAREIN 24150/51/52 Multiparametric analysers of the 24150/51/52 series

Available references

Reference Description Sales unit
GM23980 (23980) Triglyceride control solution for MULTICAREIN – this product 1 pc

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s original reference 23980 (SKU Cahnos GM23980), within the family of control solutions of the MULTICAREIN system. At present, no validated 1:1 equivalence with codes from other manufacturers has been found in reliable sources; any substitution must be verified against the technical data sheet and the instructions for use of the corresponding manufacturer, since the calibration and reading curve are specific to each analytical platform.

The reagent is complemented by the rest of the MULTICAREIN range available at Cahnos: the multiparametric analysers GM24147 / GM24148 and the Starter Kit GM24149, the triglyceride test strips with coding chip GM24160 (box of 5) and GM24161 (box of 25), and the cholesterol strips GM24158 / GM24159 for the same multichannel system. For other parameters from the same manufacturer, the GIMACARE platform offers control solutions such as lactate (ref. GM24141).

5. Selection tips and variants of interest

Select this control solution if you have a MULTICAREIN analyser from the indicated series and wish to periodically validate the triglyceride channel within your quality control programme. It is recommended to perform the verification with each new batch of test strips and periodically according to the centre’s usage volume. To complete the system, combine the reagent with the original triglyceride test strips (GM24160 or GM24161) and the cholesterol strips (GM24158 or GM24159) from the same system. Always consult the manufacturer’s instructions regarding storage, use and expiry of the reagent. For large orders you can request a quote: request conditions and technical advice from your Cahnos sales advisor.

Additional information

Manufacturer reference

23980

CND code

W0101059099

EAN

8032937230443

Control parameter

Triglycerides

Format

Liquid control solution

Compatibility

MULTICAREIN analysers 23147/8/9, 23965/66/67, 24150/51/52

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF