Combined Antigen Test Kit for SARS-CoV-2, Influenza A/B and RSV | Rapid Multiplex 4-in-1 Test with Nasopharyngeal Swab for Differential Diagnostics of Respiratory Infections at the Point of Care (IU-COVTESGVRS-1)

61,63 €

4-in-1 combined antigen test kit for the simultaneous detection of SARS-CoV-2 (COVID-19), influenza A, influenza B and respiratory syncytial virus (RSV) from a single nasopharyngeal swab sample. Lateral flow immunochromatography (LFIA) technology with reliable result in approximately 15 minutes and direct visual reading, without the need to send the sample to the laboratory or additional equipment. Ideal for the rapid differential diagnosis of seasonal respiratory infections in hospitals, emergency departments, primary care, private practices and care homes. B2B reference available at Cahnos with special conditions for professionals and healthcare centres.

International shipping. Import duties and taxes are payable by the recipient.

Reference
IU-COVTESGVRS-1

Description

1. Commercial Introduction

The SARS-CoV-2, Influenza A/B and RSV Combined Antigen Test Kit is a rapid diagnostic test designed to resolve in a single determination the most frequent clinical question of the respiratory infection season: is it COVID-19, is it flu or is it respiratory syncytial virus? With a single nasopharyngeal sample and in a few minutes, the healthcare professional obtains a differential and reliable result directly at the point of care, without depending on the laboratory. An agile and practical solution for hospitals, emergency departments, health centres, private practices, pharmacies and care homes that need to streamline the clinical decision of isolation or treatment during epidemic peaks.

2. Technical explanation of the procedure

This kit uses lateral flow immunochromatography (LFIA) technology for the qualitative detection of viral antigens. The specific antibodies immobilised on the cassette membrane capture the antigens present in the nasopharyngeal sample: the nucleocapsid protein of SARS-CoV-2, the nucleoproteins of influenza A and B and the RSV antigens. After inserting the swab into the tube with the extraction solution, the sample migrates by capillary action along the test strip and the appearance of coloured lines in each test zone indicates the presence of the corresponding pathogen, while the control line (C) validates the correct functioning of the assay.

Summary procedure:

  • Allow the kit to reach room temperature and wash your hands.
  • Take the sample with the sterile swab via the nasopharyngeal route.
  • Insert the swab into the blood collection tube with the buffer and mix properly.
  • Add the sample to the indicated well (S) of the cassette.
  • Wait the indicated minutes and read the result; the control line must always appear to validate the test.

3. Technical Specifications

Parameter Specification
Type Combined antigen test kit
Viruses detected SARS-CoV-2 (COVID-19), influenza A, influenza B, RSV
Sample Nasopharyngeal swab
Result In a few minutes (approx. 15 minutes according to the catalogue’s reference family)
Detection method Lateral flow immunochromatography (LFIA), qualitative antigen detection
Format Test cassette / single-use kit with multi-result reader
Reference method PCR
Scope of use Clinical and hospital: in vitro diagnostics at the point of patient care
Presentation Individual single-use kit
Interpretation Visual reading: a coloured line in each test region indicates positivity for that virus; the control line confirms the validity of the assay

The result is interpreted visually and requires no additional instrumentation. Consult the technical data sheet and the instructions for use included in the packaging before use.

4. Equivalences and Cross-References

This reference (IU-COVTESGVRS-1) is part of the Cahnos respiratory rapid test family and has direct functional equivalence with other combined panels in the catalogue:

  • ISIR-9334 – Combined antigen test COVID-19 / Influenza A and B / RSV (same viral coverage, nasopharyngeal swab, reading in 15 minutes).
  • MF-71-1 – Multiplex 4-in-1 self-test Covid | Influenza A and B | RSV from fluorecare (nasal swab, reading in 12 minutes).
  • TES-H107 – Professional triplex antigen test Covid | Influenza A/B | RSV from Hightop (box of 20 kits).
  • IRT-545 / IRT-545-1 – Expanded panels that add adenovirus to the Covid + Influenza A/B + RSV spectrum.
  • IU-COVTESG-8 and ICIC-525 – Combined rapid tests COVID-19 and influenza A/B (reduced spectrum, without RSV).
  • COIF-522 / COIF-522C – Multiplex antigen test Covid | Influenza A and B from SEJOY (adults and paediatric, box of 25 units).

The choice of one reference or another will depend on the desired viral coverage, the number of tests per package and the scope of application (professional use, self-test or mass screening).

5. Selection tips and variants of interest

  • Quadruple coverage in a single sample: this kit differentiates SARS-CoV-2, influenza A, influenza B and RSV, ideal for the differential diagnosis of winter respiratory infections.
  • Point of care: result in a few minutes and without additional equipment, designed for emergency departments, primary care, private practices and care homes.
  • Paediatrics and geriatrics: assess the tolerance of nasopharyngeal swabbing and follow the recommended collection protocol to minimise discomfort.
  • Volume and budget: if your centre prefers multiple professional packages, consider TES-H107 (20 kits) or COIF-522/522C (25 kits); if you also need to cover adenovirus, choose IRT-545/IRT-545-1.
  • Clinical recommendation: confirm positive results by PCR before making therapeutic decisions, especially in at-risk populations.
  • Storage: keep the kit in its sealed packaging, at room temperature, protected from moisture and respect the indicated expiry date.

Additional information

Product type

Combined antigen test kit

Viruses detected

SARS-CoV-2 (COVID-19), influenza A, influenza B, Respiratory Syncytial Virus (RSV)

Sample type

Nasopharyngeal swab

Detection method

Lateral flow immunochromatography (LFIA)

Result time

A few minutes (approx. 15 minutes in the reference family)

Reference method

PCR

Format

Test cassette / single-use kit with multi-reader

Scope of use

Clinical and hospital, point-of-care diagnostics

Presentation

Individual kit

Reviews

There are no reviews yet.

Be the first to review “Combined Antigen Test Kit for SARS-CoV-2, Influenza A/B and RSV | Rapid Multiplex 4-in-1 Test with Nasopharyngeal Swab for Differential Diagnostics of Respiratory Infections at the Point of Care (IU-COVTESGVRS-1)”

Your email address will not be published. Required fields are marked *