Rapid HIV AIDS 1/2 cassette test (ref. V06-INFO, model RTH1V02) for the qualitative detection of anti-HIV-1 and anti-HIV-2 antibodies together with the p24 antigen in whole blood (W), serum (S) or plasma (P), by lateral flow immunochromatography with visual reading in 15–30 minutes. Sensitivity greater than 99 % and specificity greater than 98 % according to clinical validation. Single-use cassette format, ideal for initial screening and diagnosis in STI clinics, gynaecology, primary care, emergency departments and public health. Professional presentation in a box of 40 cassettes. Price per box.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
V06-INFO

Description

1. Commercial Introduction

The HIV 1/2 Test cassette (ref. V06-INFO) is a professional-use in vitro diagnostic device designed for the simultaneous detection of antibodies against human immunodeficiency virus type 1 (HIV-1) and type 2 (HIV-2), as well as the p24 antigen, in a single test. Its visual-read cassette format allows a reliable result in 15–30 minutes without the need for laboratory equipment, making it the ideal solution for initial screening and diagnostic guidance in STI clinics, gynaecology services, health centres, emergency departments, clinical laboratories and public health programmes.

2. Technical explanation of the procedure

The test is a lateral flow chromatographic immunoassay in which the cassette membrane incorporates recombinant antigens of HIV-1 and HIV-2, together with specific reagents for the p24 antigen. When the sample (whole blood, serum or plasma) is placed in the well, the antibodies and/or the antigen present migrate with the conjugate and generate visible coloured lines in the reading window. The inclusion of the p24 antigen, an early marker of acute infection, reduces the diagnostic window compared to tests that only detect antibodies, facilitating early detection. The appearance of the control line (C) validates that the test has been performed correctly; the presence of a line in the test area (T) indicates a reactive result, which must always be confirmed with laboratory methods (ELISA/Western blot) according to the national screening algorithm.

3. Technical Specifications

Parameter Specification
Reference Cahnos V06-INFO
Model / manufacturer code RTH1V02 (code not verifiable in public sources; confirm with the manufacturer before use in tenders)
Format Single-test cassette, visual read
Analytes detected Anti-HIV-1 antibodies, anti-HIV-2 antibodies and p24 antigen
Method Lateral flow chromatographic immunoassay (immunochromatography)
Sample type Whole blood (W), serum (S) or plasma (P)
Time to result Between 15 and 30 minutes (visual read)
Sensitivity Greater than 99% according to clinical validation
Specificity Greater than 98% according to clinical validation
Presentation Box of 40 units (individually packaged cassettes)
Storage Ambient temperature (2–30 °C), in original sealed packaging, cool and dry place; do not freeze
Use In vitro diagnostic for professional use (not suitable for self-diagnosis)

Note: positive or equivocal results must be confirmed with a reference method (ELISA, Western blot or other confirmatory test) before making clinical decisions.

4. Equivalences and Cross-References

The reference V06-INFO belongs to the category of rapid combined antibody and p24 antigen tests for HIV (functionally equivalent to 4th-generation assays). The references listed below have been cross-checked against official catalogues and data sheets from the respective manufacturers; they are expressed as functional category comparisons and are not 1:1 interchangeable, so they must be validated property by property before any substitution.

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
ALLTEST Biotech (JusChek® range) HIV 1/2 Antibody Rapid Test Cassette IHI-402 (box of 40 kits) Comparable by category (not interchangeable 1:1) Same cassette format, same sample types (W/S/P) and same presentation of 40 kits per box. It differs in that it detects only anti-HIV-1/2 antibodies (without p24 antigen). Declared relative sensitivity of 99.8%.
Abbott (Point of Care) Determine™ HIV-1/2 Ag/Ab Combo 7D2648 (25 tests) Comparable by category (not interchangeable 1:1) 4th-generation combined test that detects HIV-1/2 antibodies and p24 antigen in serum, plasma and capillary or venous whole blood; reading at 20 minutes. Presentation of 25 tests per kit. Verified in GUDID (DI 10811877010293).
BTNX Inc. Rapid Response® HIV 1/2 Test Cassette HIV1/2-13C40 (40 tests/kit) Comparable by category (not interchangeable 1:1) Same cassette format, same sample types (W/S/P) and same presentation of 40 tests per kit. Detects only HIV-1/2 antibodies (without p24); reading in 10 minutes and published accuracy of 99.9%.
SeKBio HIV Ag/Ab Combo 4th Generation Rapid Test SEK-G102 (25 tests/kit) Comparable by category (not interchangeable 1:1) 4th-generation combo (HIV-1/2 antibodies + p24 antigen) in cassette W/S/P, reading in 15 minutes; presentation of 25 tests per kit. Panel sensitivity of 100% and specificity of 99.35% (NMPA panel).

There is no equivalence table validated by the manufacturer for the reference RTH1V02 / V06-INFO; consult the technical department before use in tenders. The model code RTH1V02 could not be verified in public sources (official catalogues, GUDID or EUDAMED), so it must be confirmed with the manufacturer or distributor before contractual use.

5. Selection tips and variants of interest

  • Professional use: indicated for healthcare centres, clinical staff and laboratories; not a self-test for home use.
  • Sample type: accepts whole blood, serum or plasma. For serum or plasma, prior centrifugation is required; for capillary blood, a sterile lancet and capillary tube will be needed (not included).
  • Quality control: verify the control line (C) on each test; if it does not appear, the result is not valid and the test must be repeated with a new cassette.
  • Advantage of p24 antigen: by combining antibodies and antigen, this test reduces the diagnostic window compared to antibody-only tests, allowing detection of infection at an earlier stage.
  • Storage: keep the cassettes in their original sealed packaging, in a cool, dry place at room temperature (2–30 °C), protected from moisture and direct sunlight, and within the expiry date.
  • Combined STI screening: for a complete battery in a single campaign, complement this test with the rapid tests for syphilis (ISY-N402), gonorrhoea (IGO-502) and chlamydia (ICH-502) from the catalogue.

Additional information

Product type

Rapid in vitro diagnostic test (RDT) in cassette

Method

Lateral flow chromatographic immunoassay (immunochromatography)

Analytes detected

Anti-HIV-1 antibodies, anti-HIV-2 antibodies and p24 antigen

Generation

Ag/Ab combo (functionally equivalent to 4th-generation test)

Sample type

Whole blood (W), serum (S) and plasma (P)

Format

Visual-read cassette, single-use

Time to result

15–30 minutes

Sensitivity

Greater than 99% according to clinical validation

Specificity

Greater than 98% according to clinical validation

Presentation

Box of 40 cassettes

Storage

2–30 °C, in original sealed packaging, cool and dry place; do not freeze

Use

Healthcare professional (in vitro diagnostic, not self-test)

Manufacturer reference

RTH1V02 (code not verifiable in public sources; confirm with the manufacturer)

Reviews

There are no reviews yet.

Be the first to review “Rapid HIV AIDS 1/2 Ag/Ab Cassette Test (HIV-1/HIV-2 Antibodies and p24 Antigen) for Whole Blood, Serum or Plasma | Box of 40 Tests | Ref. V06-INFO”

Your email address will not be published. Required fields are marked *