Description
Renal Insufficiency Test (N-GAL) for the Ref. 24600 analyser
Complete your laboratory’s diagnostic panel with the Renal Insufficiency Test (N-GAL) in cassette, a ready-to-use reagent specifically designed for the Ref. 24600 immunofluorescence analyser. With a practical presentation of 10 tests per box and immediate results, this test allows rapid and reliable monitoring of the renal function marker at the point of patient care, facilitating early detection of renal damage and guiding clinical management.
Technical explanation of the procedure
This test is based on fluorescence immunoassay technology: the sample is processed in the cassette, which is inserted into the Ref. 24600 analyser, and the fluorescence reading allows the analyte to be detected in an automated and objective manner, eliminating the subjectivity of visual reading. The kit includes everything needed to perform the test: the ID card (identification and batch calibration), the reaction cassette, the buffer solution and 1 dropper of 75 µl for sample dosing. It is a professional-use solution that combines ease of handling, speed and traceability of results, integrated into a single platform capable of processing up to 12 parameters in cassette.
Technical specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 24612 (SKU Cahnos: GM24612) |
| Sales unit | box of 10 pcs (box of 10 units) |
| Device type | IVD – Professional Use (in vitro diagnostic for professional use) |
| CND | W0102160901 |
| EAN | 6936983170086 |
| Parameter detected | Renal insufficiency (N-GAL) – nephrology |
|---|---|
| Technology | Fluorescence immunoassay (cassette test) |
| Compatibility | Immunofluorescence analyser Ref. 24600 |
| Results | Immediate, with objective reading on the analyser |
Kit contents:
- ID card
- Cassette
- Buffer solution
- 1 dropper of 75 µl
Range of cassette tests for the Ref. 24600 analyser (up to 12 parameters):
| Parameter | Reference | Category |
|---|---|---|
| CRP | 24605 | Inflammatory markers |
| Procalcitonin (PCT) | 24606 | Inflammatory markers |
| D-dimer | 24608 | Coagulation |
| Troponin I (cTnI) | 24610 | Cardiac |
| Renal insufficiency (N-GAL) | 24612 | Nephrology |
| Glycated haemoglobin (HbA1c) | 24614 | Diabetes |
| Influenza A/B | 24618 | Infectious diseases |
| Strep A | 24619 | Infectious diseases |
| VRS/RSV | 24620 | Infectious diseases |
| COVID-19 (antigen) | 24622 | Infectious diseases |
| COVID-19 (antibodies) | 24623 | Infectious diseases |
| Vitamin D | 24625 | Vitamins |
Equivalences and cross-references
There is no equivalence table validated by the manufacturer relating reference 24612 to renal insufficiency tests from other brands. This cassette must be used exclusively with the Ref. 24600 immunofluorescence analyser and is not interchangeable with rapid lateral flow tests with visual reading or with reagents from other platforms without prior validation of compatibility. Consult our technical-commercial team to confirm availability and replacement references.
Selection tips and variants of interest
Verify that you have the Ref. 24600 analyser for the use of this cassette, as it is specifically designed for this immunofluorescence platform. The presentation in a box of 10 units is the manufacturer’s standard sales unit and allows continuous replenishment planning of all parameters of your diagnostic panel from a single platform. This test is especially useful in nephrology, internal medicine and emergency services, and can be combined with other markers in the range such as Procalcitonin (24606), Glycated Haemoglobin (24614) or D-Dimer (24608) to expand diagnostic coverage. Request a quote from our technical-commercial team to plan your consumables orders and ensure the supply of the different tests in the range.