Description
1. Commercial Introduction
The rapid test for strep A throat infection (reference IST-N502) is an in vitro diagnostic device for professional use that allows you to verify in just 5 minutes whether the cause of a sore throat is bacterial, specifically by Streptococcus pyogenes (group A beta-haemolytic streptococcus). It is the ideal screening tool for community pharmacies, general practice and paediatric consultations, emergency departments and primary care: with a simple throat swab sample, the healthcare professional can guide the diagnosis, avoid the unnecessary use of antibiotics and decide more safely on the clinical management of the patient.
It is presented in a professional box of 20 tests with all the necessary materials (cassettes, sterile swabs, extraction tubes, reagents and controls), without requiring any additional equipment. Available on demand with CE declaration of conformity and CE certificate.
2. Technical explanation of the procedure
The device uses a lateral flow chromatographic immunoassay for the qualitative detection of the Strep A carbohydrate antigen in pharyngeal swabs. The specific antibodies to the antigen are attached in the test line region (T): the extracted sample migrates by capillary action through the membrane and, if it contains group A streptococcus antigens, a coloured line is generated. The control line (C) always validates the correct functioning of the assay (adequate sample volume and correct membrane absorption).
Summary procedure:
- Allow the kit to equilibrate to room temperature (15–30 °C) and wash your hands.
- Take the sample with the sterile swab by rubbing the back of the pharynx, the tonsils and other inflamed areas, avoiding touching the tongue, cheeks and teeth.
- Add 4 drops of extraction reagent 1 (red) and 4 drops of extraction reagent 2 (yellow) to the extraction tube and mix.
- Insert the swab, shake it vigorously 15 times and let it stand for 1 minute; squeeze the swab against the wall of the tube and discard it.
- Add 3 drops of the extracted solution to the well (S) of the cassette and read the result at 5 minutes. Do not interpret after 10 minutes.
The kit includes positive control and negative control as external quality controls; their use is recommended every 25 samples according to the internal protocols of the laboratory or healthcare centre.
3. Technical Specifications
General characteristics
| Parameter | Specification |
|---|---|
| Detection method | Lateral flow chromatographic immunoassay (qualitative detection of antigens) |
| Pathogen detected | Streptococcus pyogenes (group A beta-haemolytic streptococcus) |
| Sample type | Oropharyngeal swab (sterile swab) |
| Format | Test cassette / individual kit with red control line |
| Reading time | 5 minutes (do not interpret after 10 minutes) |
| Reference method | Microbiological culture with latex agglutination |
| Storage | 2 °C to 30 °C (do not freeze; keep in the sealed pouch until use) |
| Use | In vitro diagnostic for professional use (TROD) |
| Certification | CE marking IVDR 2017/746 · Manufactured under ISO 13485 |
Packaging
| Item | Value |
|---|---|
| Tests per box | 20 tests per box |
| Boxes per carton | 25 boxes per carton // 500 tests per carton |
| Carton weight and dimensions | 9.3 kg / 63 × 37 × 30 cm per carton |
Box contents
| Materials included | Quantity |
|---|---|
| Instructions for use | 1 |
| Test cassettes | 20 |
| Extraction tubes | 20 |
| Sterile swabs | 20 |
| Dropper tips | 20 |
| Extraction reagent 1 (red cap) | 1 |
| Extraction reagent 2 (yellow cap) | 1 |
| Positive control (blue cap) | 1 |
| Negative control (green cap) | 1 |
Clinical data
| Parameter | Value |
|---|---|
| Clinical sensitivity | 96.1 % |
| Clinical specificity | 97.7 % |
| Accuracy | 97.2 % |
4. Equivalences and Cross-References
Reference IST-N502 corresponds to the Strep A Rapid Test Cassette (Throat Swab) from the ACRO Biotech / Hangzhou AllTest Biotech family (original ref. IST-502), an international standard of lateral flow immunochromatography for the detection of group A streptococcus antigens in pharyngeal swabs. This same device is marketed in Europe under other equivalent references, such as the SPINREACT technical data sheet A0159 or the formats distributed by Akralab/Akratest, with identical technical specifications, 5-minute reading time and internal and external controls included.
Within the Cahnos rapid test catalogue, it shares technology and cassette format with other TRODs of bacterial and respiratory aetiology, allowing a comprehensive diagnostic panel to be completed for the point of care:
- IBP-502 – Rapid antigen test for Bordetella pertussis (whooping cough), same AllTest family, box of 20 tests with swab.
- IMP-502 – Rapid antigen test for Mycoplasma pneumoniae, same AllTest family.
- IRT-545 / IRT-545-1 – Combined panels SARS-CoV-2 / Influenza A and B / RSV / Adenovirus.
- ICIC-525 – Combined rapid antigen test for Covid-19 and Influenza A+B.
- COIF-522 / COIF-522C – Covid multiplex antigen test | Flu A and B for professional use.
5. Selection tips and variants of interest
- Professional use: indicated for pharmacies, medical practices, paediatrics, emergency departments and clinical laboratories; it is not a home-use self-test. Like all TRODs, it should be used as an aid to diagnosis together with clinical assessment.
- Confirmation of results: In the event of a positive result, therapeutic decisions can be initiated quickly; negative or doubtful results should be confirmed by microbiological culture, especially in paediatric or at-risk patients.
- Sample collection: Perform the pharyngeal swab always on the posterior pharynx and tonsils, avoiding the tongue and bleeding areas, to maximise antigen concentration and avoid interference.
- Volume and cost per determination: The presentation of 20 tests per box (500 tests per carton) optimises the cost per test and storage in centres with medium and high demand. Request special conditions for full-carton orders through our commercial team.
- Storage: Keep the cassettes in their sealed packaging between 2 °C and 30 °C, protected from humidity and direct sunlight; do not freeze and respect the indicated expiry date.
- Quality control: Perform the external positive and negative controls included in the box every 25 samples or according to the centre’s quality plan.





Reviews