Description
1. Introduction
The D-dimer cassette test is the reference diagnostic solution for assessing coagulation activation and thrombus formation at the point of patient care. Specifically designed for the fluorescence immunoassay analyser Ref. 24600, it provides immediate, reliable and reproducible results without the need for large equipment or laboratory infrastructure. Ideal for emergency departments, intensive care units, clinical laboratories, internal medicine practices and primary care centres that require a rapid response when venous thromboembolic disease is suspected, as well as for monitoring patients with thrombotic processes or hypercoagulability.
2. Technical explanation of the test
D-dimer is a fibrin degradation product that rises in the blood when the coagulation process and subsequent fibrinolysis are activated, making it a highly useful clinical marker for excluding deep vein thrombosis and pulmonary embolism, among other indications. This cassette is ready to use: the sample is obtained using the included safety lancet and applied to the cassette with the 75 µl precision dropper; the cassette is then inserted into the Ref. 24600 analyser, which performs the reading by fluorescence immunoassay and provides the result immediately and objectively, eliminating the subjectivity of visual interpretation. The kit includes all the elements needed for the determination: identification card (batch identification and calibration), reaction cassette, buffer solution, safety lancets and one 75 µl precision dropper. This reference is part of a family of 12 cassette tests in the catalogue compatible with the same analyser, allowing the diagnostic panel to be centralised on a single piece of equipment.
3. Technical specifications and product data
| Parameter | Value |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 24608 (SKU Cahnos: GM24608) |
| Sales unit | Box of 10 units (box of 10 pcs) |
| Device type | IVD – Professional use (IVD – Professional Use) |
| CND | W0103020803 |
| EAN | 6936983170109 |
| Parameter detected | D-dimer (coagulation) |
| Technology | Fluorescence immunoassay (cassette test) |
| Compatibility | Immunofluorescence analyser Ref. 24600 |
| Results | Immediate, with objective reading on the analyser |
Kit contents
| Item | Description |
|---|---|
| Identification card | ID Card (batch identification and calibration) |
| Test cassette | Ready to use |
| Buffer solution | Buffer |
| Safety lancets | For obtaining capillary blood samples |
| Precision dropper | 1 dropper of 75 µl |
Range of cassette tests for the analyser Ref. 24600
| Parameter | Reference | Category |
|---|---|---|
| CRP | 24605 | Inflammatory markers |
| Procalcitonin (PCT) | 24606 | Inflammatory markers |
| D-dimer | 24608 | Coagulation |
| Troponin I (cTnI) | 24610 | Cardiac |
| Renal insufficiency (N-GAL) | 24612 | Nephrology |
| Glycated haemoglobin (HbA1c) | 24614 | Diabetes |
| Influenza A/B | 24618 | Infectious diseases |
| Strep A | 24619 | Infectious diseases |
| VRS/RSV | 24620 | Infectious diseases |
| COVID-19 (antigen) | 24622 | Infectious diseases |
| COVID-19 (antibodies) | 24623 | Infectious diseases |
| Vitamin D | 24625 | Vitamins |
4. Equivalences and Cross-References
The cassette system for the 24600 analyser is a closed system: no direct equivalences with cassettes from other manufacturers have been verified in reliable sources. To ensure the reliability of results, this test (reference 24608, SKU Cahnos GM24608) must be used exclusively with the Ref. 24600 analyser and is not interchangeable with rapid lateral flow tests with visual reading or with reagents from other platforms without prior validation of compatibility. The same family of cassettes for this analyser, available in the Cahnos catalogue, includes: CRP test (GM24605), procalcitonin test (GM24606), Troponin I cTnI test (GM24610), renal failure test (GM24612), glycated haemoglobin test (GM24614), Influenza A/B test (GM24618), Strep A test (GM24619), RSV test (GM24620), COVID-19 test in its antigen (GM24622) and antibody (GM24623) variants, and vitamin D test (GM24625).
5. Selection tips and variants of interest
Verify that you have the Ref. 24600 analyser for use with this cassette, as it is specifically designed for this immunofluorescence platform. The presentation in a box of 10 units is the manufacturer’s standard sales unit and allows continuous replenishment planning of all parameters of your diagnostic panel from a single platform. This test is especially useful in emergency departments, internal medicine and surgical services, and can be combined with other markers in the range, such as Troponin I cTnI (GM24610) for cardiac assessment or procalcitonin (GM24606) as support in the diagnosis of infectious processes. Request a quote from our technical-commercial team to plan your consumables orders and ensure the supply of the different tests in the range. For any questions about compatibility or selection of variants, our team is at your disposal.





Reviews
There are no reviews yet.