We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rapid Test Anti-HBs Ab (Rapidian) Hepatitis B – Anti-HBs Antibodies in Blood, Serum and Plasma (S/S/P) – Box 40 uds | Ref. V05-1-INFO

90,00 €

Anti-HBs Ab Test (Rapidian) for the qualitative detection of antibodies against the hepatitis B surface antigen (anti-HBs) in whole blood, serum or plasma samples (S/S/P format). Professional presentation in box of 40 units (ref. V05-1-INFO), ideal for assessing post-vaccination immunity and serological screening in gynaecology clinics, laboratories, primary care, occupational health and blood banks. Single-use rapid test for in vitro diagnostics, without the need for additional equipment.

International shipping. Import duties and taxes are payable by the recipient.

Reference
V05-1-INFO

Description

1. Commercial Introduction

The Anti-HBs Ab Test (Rapidian) is a rapid in vitro diagnostic test designed for the qualitative detection of anti-HBs antibodies (HBsAb), the serological marker of immunity against the hepatitis B virus. It provides results within minutes to determine whether the patient has developed immune protection after vaccination or after a resolved infection, without the need for laboratory instrumentation.

Supplied in a box of 40 units (ref. V05-1-INFO), it is intended for professional use in gynaecology and obstetrics clinics, clinical laboratories, primary care, occupational health units, blood banks and serological screening campaigns. Its S/S/P format (whole blood, serum or plasma) allows the sample collection to be adapted to the usual workflow of each centre, optimising the cost per test in services with medium and high demand.

2. Technical explanation of the procedure

The hepatitis B virus surface antigen (HBsAg) is the marker of active infection, while anti-HBs antibodies are the indicator of immunity: they appear after hepatitis B vaccination or after resolution of an acute infection, at which point HBsAg disappears. Determining anti-HBs is essential for verifying the need for and success of vaccination and for monitoring the progression of the disease after an acute HBV infection.

This rapid test is based on the lateral flow immunochromatography technique, commonly used in the family of rapid serological tests (confirm the assay details in the manufacturer’s instructions for use). When the sample is placed together with the buffer solution on the device, the anti-HBs antibodies present migrate by capillary action and react with the conjugate, producing a coloured line in the test (T) zone. A control line (C) validates in each assay that migration and sample volume have been correct:

  • Positive (reactive): two lines appear (test and control).
  • Negative (non-reactive): only the control line appears.
  • Invalid: absence of control line; repeat the test with a new device.

The reading is qualitative and visual, suitable for qualified healthcare personnel without advanced training. Positive or doubtful results must be confirmed with reference laboratory methods (ELISA, chemiluminescence or anti-HBs quantification) before making clinical decisions.

3. Technical Specifications

Parameter Specification
Test type Anti-HBs antibody detection test (qualitative)
Analyte detected Anti-HBs antibodies (HBsAb) against the hepatitis B surface antigen
Format S/S/P (Blood / Serum / Plasma)
Sample type Whole blood, serum or human plasma
Result type Qualitative, visual reading (test T line and control C line)
Presentation Box of 40 units (price per box)
Reference Cahnos V05-1-INFO
Use In vitro diagnostics (IVD) by qualified healthcare personnel, single-use
Storage Ambient temperature (2-30 °C); do not freeze; protect from humidity and direct sunlight; keep in sealed packaging until use
Marking In vitro diagnostic medical device (CE marking; declaration of conformity available on request)

Interpretation of results

Reading Interpretation
Two lines (T and C) Positive: presence of anti-HBs antibodies; confirm with reference method according to clinical protocol
Only control line (C) Negative (non-reactive)
No control line Invalid: repeat the test with a new device

Note: the acronym S/S/P refers to the accepted sample matrices (Whole Blood / Serum / Plasma). Clinical performance data (sensitivity/specificity) and the exact kit contents are given in the manufacturer’s technical data sheet, available on request from our technical department.

4. Equivalences and Cross-References

Reference V05-1-INFO belongs to the category of rapid tests for the qualitative detection of anti-HBs antibodies (HBsAb) in blood, serum or plasma samples by lateral flow immunochromatography, intended for assessing immunity against hepatitis B. The references from other manufacturers listed below are functional category comparisons verified against official catalogues and technical documents from the respective manufacturers; they are not interchangeable 1:1 and must be validated property by property (analyte, sample type, volume, reading time, presentation and certification) before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
SD Biosensor STANDARD Q Anti-HBs Test 09AHB10D (25 tests) / 09AHB10F (100 tests) Comparable by category (not interchangeable 1:1) Same analyte (anti-HBs) in whole blood, serum or plasma; 100 µL sample; reading in 15-30 minutes; storage 2-40 °C. Sensitivity 98.5% and specificity 98.0% versus CLIA according to the manufacturer’s catalogue. Codes confirmed in the official SD Biosensor catalogue.
Fortress Diagnostics Anti-HBs Rapid Test (HBsAb), 40-test format HBSAB040 (40 tests) Comparable by category (not interchangeable 1:1) Double antigen sandwich immunoassay for qualitative detection of HBsAb in serum or plasma, with a detection limit of 30 mIU/mL. Presentation of 40 tests per box, same packaging format. Code confirmed on the manufacturer’s official website.

No validated equivalence table exists from the manufacturer for this reference; consult the technical department before use in tenders. The equivalences indicated are functional category comparisons, not 1:1 substitutes: before substituting, verify in each technical data sheet the analyte detected (anti-HBs/HBsAb), the authorised sample type, sample volume, reading time, presentation and CE certification. Other brands and homologous families available on the market (ALLTEST/JusChek, CTK Biotech, BTNX, HYSEN, Biorex Diagnostics, Vitrosens) offer products in the same category, although their reference codes must be confirmed against an official source before use. Within the Cahnos catalogue, this test is complemented by the HBsAg test (V05-INFO and IHBSG-402), the hepatitis C test (V05C-INFO and IHC-402) and the hepatitis E test (IHE-302), allowing the hepatitis serological panel to be completed with a single supplier.

5. Selection tips and variants of interest

  • Immunity assessment: anti-HBs detection is the indicated tool for checking the response to the hepatitis B vaccine and immunity after resolved infection (titres ≥10 mIU/mL are considered protective according to international criteria; this test provides a qualitative result).
  • Hepatitis serology panel: combine this Anti-HBs test with HBsAg determination (active infection, ref. V05-INFO or IHBSG-402) and consider adding the hepatitis C (V05C-INFO / IHC-402) and hepatitis E (IHE-302) tests for comprehensive liver screening in gynaecology and obstetrics.
  • Sample type: the S/S/P format accepts whole blood, serum or plasma; follow the collection and dosing instructions in the package leaflet to ensure the validity of the result.
  • Throughput: the box of 40 units offers the best cost per test for laboratories, high-flow clinics and screening campaigns; contact our commercial team for special conditions on volume orders.
  • Confirmation: positive or equivocal results must be confirmed by reference laboratory methods (ELISA, chemiluminescence or quantification) before making clinical decisions.
  • Storage and use: store the devices at 2-30 °C, protected from humidity and direct sunlight, respect the expiry date and use each test only once; treat all samples as potentially infectious.

Additional information

Product type

Rapid serological antibody test (TROD)

Analyte detected

Anti-HBs antibodies (HBsAb) against the hepatitis B surface antigen

Detection method

Lateral flow immunochromatography (rapid test; confirm assay details in IFU)

Sample type

Whole blood, serum or plasma (S/S/P)

Result time

Approximately 15 minutes (visual reading)

Format

S/S/P (Blood/Serum/Plasma)

Presentation

Box of 40 units (price per box)

Result type

Qualitative, visual reading

Use

In vitro diagnostic (IVD) for qualified healthcare personnel, single-use

Storage

2-30 °C; do not freeze; protect from moisture and direct sunlight; keep in sealed packaging

Certifications

In vitro diagnostic medical device (CE marking; declaration of conformity on request)

Manufacturer reference

Not verifiable in public sources; confirm with the manufacturer before use in tendering

Reading

Qualitative and visual (test line T and control line C)

Clinical indication

Assessment of immunity against hepatitis B (post-vaccination or after resolved infection)

Reviews

There are no reviews yet.

Be the first to review “Rapid Test Anti-HBs Ab (Rapidian) Hepatitis B – Anti-HBs Antibodies in Blood, Serum and Plasma (S/S/P) – Box 40 uds | Ref. V05-1-INFO”

Your email address will not be published. Required fields are marked *