Control Strips for the MISSION® Hb Haemoglobin and Haematocrit System (Ref. 24022) – Box of 2 Units, IVD for Professional Use | SKU GM24027

5,51 €

The control strips for the MISSION® Hb haemoglobin and haematocrit analysis system (ref. 24022, SKU GM24027) are the official quality control kit for the portable Hb/Hct analyser. They are supplied in a box of 2 units (kit with 2 control vials) and allow validation of the accuracy of readings and the condition of each batch of reagent strips before clinical use, ensuring the reliability of determinations in practices, clinical laboratories and emergency departments. In vitro diagnostic (IVD) product for professional use, distributed by Cahnos. For large orders, you can request a quote.

Sales unit: caja de 2
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM24027

Description

1. Product Presentation

The control strips for the MISSION® Hb portable haemoglobin and haematocrit analyser are the official quality control kit for the Hb/Hct analysis system (factory reference 24022, SKU Cahnos GM24022). This reference, factory code 24027 (SKU Cahnos GM24027), is supplied in a box of 2 units, as a kit with 2 control vials, and is integrated into the quality assurance routine of the MISSION® Hb analyser in medical practices, health centres, clinical laboratories and emergency departments. It is an in vitro diagnostic (IVD) product for professional use, distributed in Spain by Cahnos. For large orders, you can request a quote.

2. Technical explanation of quality control

The MISSION® Hb analyser determines haemoglobin (Hb) and haematocrit (Hct) by reflectance photometry from a microsample of whole blood (10 µl), with results in less than 15 seconds and automatic calibration via a code chip. To ensure the reliability of each batch of reagent strips, the manufacturer recommends performing a quality control with these specific control strips before putting them into service: the control is processed in the device as if it were a sample, and the value obtained must fall within the acceptance range indicated by the manufacturer. This verifies the correct optical functioning of the device and the validity of the strip batch, reducing the risk of erroneous results. Always use the control strips corresponding to the MISSION® Hb system (ref. 24022), following the handling, storage and expiry instructions on the packaging.

3. Technical Specifications

The available references and the product registration data are detailed below, preserving the original manufacturer’s information:

Available references

Reference Sales unit
GM24027 (code 24027) Box of 2 units (box of 2 pcs)

Product data

Manufacturer GIMA
Sales unit Box of 2 units (box of 2 pcs)
Device type IVD – Professional use
CND W0103010504
EAN 8023279240276

Compatible system

Parameter Detail
Compatible analyser Haemoglobin and haematocrit analysis system MISSION® Hb (ref. 24022, SKU GM24022)
Purpose of the control Validation of the reagent strip batch and quality control of the analyser
Presentation Control kit with 2 vials
Scope of use Professional use (IVD)

4. Equivalences and Cross-References

This reference corresponds to the official factory code Ref. 24027, marketed by Cahnos under SKU GM24027, and constitutes the quality control kit for the MISSION® Hb system (ref. 24022). The MISSION® Hb analyser is supplied with 2 initial control strips, so this box of 2 units is the recommended replacement presentation to maintain the system’s quality control routine. There is no reliable source providing a 1:1 equivalence table with control solutions or strips from other manufacturers: the optical compatibility of the control elements is specific to the MISSION® Hb platform, so it is recommended to use exclusively the original reference and to validate any substitution with the technical-commercial department of Cahnos before its use in tenders.

5. Selection tips and variants of interest

If your centre has the MISSION® Hb analyser (ref. 24022, SKU GM24022), plan the periodic replacement of this control kit (ref. 24027) together with the reagent strips, lancets and capillary tubes of the system, as well as the specific calibration code chip. Perform quality control when opening a new batch of strips and periodically according to the centre’s internal protocol, and always check the expiry date and integrity of the vials before use. Store the material in its original packaging, protected from humidity and direct light. For institutional volumes, multi-unit supplies or specific B2B supply conditions, contact the technical-commercial team of Cahnos.

Additional information

Manufacturer reference

24027

Unit of sale

Box of 2 units (box of 2 pcs)

CND code

W0103010504

EAN

8023279240276

Presentation

Control kit with 2 vials

Compatible system

Haemoglobin and haematocrit analysis system MISSION® Hb (ref. 24022)

Intended use

Analyser quality control and reagent strip batch validation

Use

Professional use

Presentacion

Kit, Pack of 2

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF