Cholesterol Control Solution for MULTICAREIN Analysers (Ref. 23979, IVD Self-Test)

54,15 €

Original cholesterol control solution. for periodic verification of the multiparameter analyser MULTICAREIN (references 23147/8/9, 23965/66/67 and 24150/51/52). A liquid quality control reagent (IVD – Self Test) that allows checking that the device and cholesterol test strips provide accurate, repeatable and traceable measurements within the system’s cholesterol channel range (130-400 mg/dL – 3-10.2 mmol/L). Indicated for pharmacies, orthopaedic shops, health centres and cardiovascular prevention programmes, as well as for patient self-monitoring. Factory reference 23979 · SKU Cahnos GM23979 · EAN 8032937230436. For large orders you can request a quote: contact our technical-commercial team for B2B conditions.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23979

Description

1. Commercial Introduction

The Cholesterol Control Solution for MULTICAREIN (ref. 23979) is the essential verification accessory to guarantee the reliability of your multiparameter lipid profile analyser. Designed and manufactured, it allows you to easily check that the device and the cholesterol test strips in use provide accurate and repeatable measurements. It is the recommended choice for pharmacies, orthopaedic shops, health centres and patients who carry out periodic monitoring of their cardiovascular profile, providing traceability and confidence to each analytical result.

2. Technical explanation of the procedure

The control solution is a liquid sample with a known cholesterol concentration used to verify the operation of the analyser and the batch of test strips in use. When the control solution is applied to a strip, the device must obtain a result within the range of values indicated on the packaging and in the manufacturer’s instructions. If the result falls outside this range, it is recommended to repeat the control and, if the deviation persists, replace the strips or check the condition of the device.

The compatible range of MULTICAREIN analysers uses reflectometric technology for cholesterol determination, with a measurement range of 130-400 mg/dL (3-10.2 mmol/L), a sample volume of 10 µl and a measurement time of 30-60 seconds. Periodic use of this control solution is key to maintaining measurement accuracy, system traceability and the quality of self-monitoring. The product is classified as an in vitro diagnostic device for self-testing (IVD – Self Test), so it can be used by the end user themselves.

3. Technical Specifications

Manufacturer GIMA
Manufacturer reference 23979 (SKU Cahnos: GM23979)
Product Cholesterol control solution for MULTICAREIN analysers
Compatible equipment MULTICAREIN analysers: 23147/8/9, 23965/66/67, 24150/51/52
Verified parameter Cholesterol
Sales unit 1 pc
Device type IVD – Self Test
CND W0101059099
EAN 8032937230436

Features of the cholesterol channel of compatible devices

Parameter Specification
Technology Reflectometric
Measurement range 130-400 mg/dL – 3-10.2 mmol/L
Sample volume 10 µl
Measurement time 30″-60″

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s original reference 23979 (SKU Cahnos GM23979, EAN 8032937230436), within the range of control solutions for the MULTICAREIN platform. No exact equivalents from third-party manufacturers have been verified in reliable sources for this control solution: controls are consumables specific to each analytical platform and their validation depends on the device and the batch of strips, so it is recommended to always use the original control to ensure traceability of results.

Within the ecosystem, the MULTICAREIN multiparameter analyser family (refs. 24147/24148 and Starter Kit 24149) shares the technical scheme with the 23147/8/9, 23965/66/67 and 24150/51/52 series. For other manufacturer platforms, Cahnos also offers the cholesterol control solution for GIMACARE 24128 (ref. GM24142) and other control solutions from the GIMACARE range; always check your device model before selecting the appropriate control.

5. Selection tips and variants of interest

Perform quality control periodically or each time you open a new pack of cholesterol test strips, and record the results obtained to verify the device’s trend. Always check that your analyser corresponds to one of the indicated MULTICAREIN references (23147/8/9, 23965/66/67 or 24150/51/52) before placing the order, as the control solution is calibrated for this specific system. Store the reagent following the manufacturer’s instructions regarding storage and expiry. For ongoing self-monitoring programmes in pharmacies, orthopaedic shops and healthcare centres, contact the technical-commercial team at Cahnos to plan periodic replenishment of consumables and obtain personalised B2B supply conditions.

Additional information

Manufacturer reference

23979

CND code

W0101059099

EAN

8032937230436

Parameter

Cholesterol

Compatibility

MULTICAREIN analysers 23147/8/9, 23965/66/67, 24150/51/52

Compatible equipment technology

Reflectometric (cholesterol channel)

Presentation

Liquid control solution

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Cholesterol Control Solution for MULTICAREIN Analysers (Ref. 23979, IVD Self-Test)”

Your email address will not be published. Required fields are marked *