We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Cholesterol Analyzer MISSION® Cholesterol Meter – 3-in-1 Lipid Profile (CHOL, HDL, TRIG) for Point-of-Care Diagnostics | Ref. 23932

179,55 €

MISSION® cholesterol meter with 3-in-1 lipid profile test that determines total cholesterol (CHOL), HDL and triglycerides (TRIG) from a single sample in about 2 minutes. The system also calculates LDL, the CHOL/HDL ratio and cardiac risk assessment, providing quantitative results in mg/dL or mmol/L.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23932

Description

1. Introduction

The MISSION® Cholesterol Meter (reference 23932, SKU Cahnos GM23932) is a portable lipid profile analyser designed for rapid point-of-care diagnostics: pharmacies, medical practices, clinical analysis centres, prevention services and cardiovascular risk screening programmes. With a single capillary blood sample obtained minimally invasively, it provides a complete lipid panel in approximately 2 minutes, with the reliability of an in vitro diagnostic (IVD) self-testing system from the MISSION® brand and distribution.

2. Technical explanation of the equipment

The meter uses the principle of reflectance photometry, with quantitative results and no prior sample preparation: it can analyse whole blood, serum or plasma. With a single 3-in-1 test device, total cholesterol (CHOL), high-density lipoprotein (HDL) and triglycerides (TRIG) are determined; from these values the device automatically calculates LDL, the CHOL/HDL ratio and cardiac risk assessment. The internal memory stores up to 200 results with date and time, and the device allows readings to be expressed in mg/dL or mmol/L. Its wide haematocrit range (0-50%), large LCD screen and colour-coded test devices with the name engraved facilitate identification and daily handling. It also has a Mini USB port for data transfer to a PC and is compatible with a small thermal printer for immediate printing of results.

3. Technical Specifications

Measurement characteristics

Parameter Specification
Detection principle Reflectance photometry
Test type Quantitative
Time to result ≤ 2 minutes
Memory with date/time 200 results
Tests CHOL, HDL, TRIG
Calculated tests LDL, CHOL/HDL ratio, cardiac risk assessment
Sample type Whole blood, serum or plasma
Sample volume 3-in-1 lipid panel device: 35 µL; individual CHOL test device: 10 µL
Measurement units mg/dL or mmol/L
Haematocrit range 0-50%

Measurement ranges

Parameter Range
CHOL (total cholesterol) 100-500 mg/dL (2.59-12.93 mmol/L)
HDL 15-100 mg/dL (0.39-2.59 mmol/L)
TRIG (triglycerides) 45-650 mg/dL (0.51-7.34 mmol/L)

Interface, calibration and power

Parameter Specification
PC interface for data transfer Mini USB port
Calibration Code chip (Code Chip)
On-screen languages Abbreviations in English
Power supply 4 AAA batteries or AC adapter (Mini USB, 5 V DC, 50 mA)
Battery life ≥ 1,000 tests
Auto power-off 5 minutes
Meter dimensions 137 × 79 × 26 mm
Weight 145 g
Screen dimensions 50 × 50 mm

Scope of delivery

  • 2 control devices
  • 4 AAA batteries
  • Carrying case
  • User manual (GB, IT); FR, ES, DE, PT manuals available on the manufacturer’s website
  • Multilingual box: GB, FR, IT, ES, DE, PT, PL, SE, FI, GR, NL, RO, BG, RU, SA

Product data

Brand MISSION
Manufacturer reference 23932
SKU Cahnos GM23932
Sales unit 1 pc
Device type IVD – Self Test
CND W0201069080
EAN 0682607610907

Available references

Reference Description
23932 (GM23932) MISSION® Cholesterol Meter analyser – 3-in-1 lipid profile (this product)

4. Equivalences and Cross-References

This reference corresponds to the official factory code. 23932, marketed by Cahnos under the SKU GM23932, within the MISSION® range of portable in vitro diagnostic (IVD) analysers. The specific consumables for this system are the 3-in-1 lipid profile test with 35 µL capillary tubes (reference 23933, SKU GM23933, box of 25 units) and the kit with safety lancets (reference 23935, SKU GM23935, box of 5 units), both for exclusive use with this analyser. As a complementary accessory, the MISSION® thermal printer (reference 23929, SKU GM23929) is available, designed for immediate printing of results from this platform. No 1:1 equivalence table with cholesterol analysers from other manufacturers has been documented in reliable sources, since the physical-optical compatibility of the test devices is specific to this platform; any comparison for tenders or stock replacement must be validated field by field with the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

The MISSION® Cholesterol Meter (GM23932) is supplied as a complete unit with starter accessories and is the basis of the MISSION® lipid profile system. To start using it or for low test volumes, the GM23935 kit (box of 5 units with safety lancets) includes everything needed for sample collection; for services with medium-high test turnover, the GM23933 reference (box of 25 units) is the most cost-effective presentation. If you need a printed record of results, consider completing the equipment with the MISSION® thermal printer (GM23929). Within the same brand ecosystem, the MISSION® Hb meter (ref. 24022, SKU GM24022) allows you to expand the bedside test panel with haemoglobin and haematocrit determination. For institutional volumes, multi-unit equipment or tender specifications, contact the technical-commercial team of Cahnos. No price is published and conditions are managed through our commercial department. For large orders you can request a quote.

Additional information

Manufacturer reference

23932

CND code

W0201069080

EAN

0682607610907

Detection principle

Reflectance photometry

Test type

Quantitative

Time to result

≤ 2 minutes

Memory

200 results with date and time

Tests

CHOL, HDL, TRIG

Calculated tests

LDL, CHOL/HDL ratio, cardiac risk assessment

Sample type

Whole blood, serum or plasma

Sample volume

35 µL (3-in-1 panel); 10 µL (individual CHOL)

Measurement units

mg/dL or mmol/L

Haematocrit range

0-50%

CHOL range

100-500 mg/dL (2.59-12.93 mmol/L)

HDL range

15-100 mg/dL (0.39-2.59 mmol/L)

TRIG range

45-650 mg/dL (0.51-7.34 mmol/L)

PC interface

Mini USB port

Calibration

Code chip (Code Chip)

On-screen languages

Abbreviations in English

Power supply

4 AAA batteries or AC adapter (Mini USB, 5 V DC, 50 mA)

Battery life

≥ 1,000 tests

Auto power-off

5 minutes

Dimensions

137 × 79 × 26 mm

Weight

145 g

Screen dimensions

50 × 50 mm

Presentation

1 pc with 2 control devices, 4 AAA batteries, carrying case and manual

Presentacion

Unit

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF
📜 CertificatesCertificati vari PDF · Dichiarazioni Varie PDF

Reviews

There are no reviews yet.

Be the first to review “Cholesterol Analyzer MISSION® Cholesterol Meter – 3-in-1 Lipid Profile (CHOL, HDL, TRIG) for Point-of-Care Diagnostics | Ref. 23932”

Your email address will not be published. Required fields are marked *