Description
1. Introduction
The semi-quantitative C-reactive protein (CRP) rapid test (reference CCR-U402) is a professional-use in vitro diagnostic device that allows the patient’s level of inflammation to be assessed within minutes from a small sample of whole blood, serum or plasma. C-reactive protein is an acute-phase marker synthesised in the liver and its concentration rises early in response to infections, inflammatory processes, tissue damage or surgical stress, making it an essential tool for point-of-care screening.
It is the ideal solution for community pharmacies, general practice and paediatric consultations, emergency departments, primary care and clinical laboratories: with simple handling, visual reading in 5 minutes and excellent clinical correlation, this test helps to guide the differential diagnosis between bacterial and viral infection, streamlining the therapeutic decision and avoiding unnecessary empirical antibiotic treatments. It is supplied in a professional box of 10 determinations with all the materials needed to perform the test, requiring only a small centrifuge and a timer when working with serum or plasma.
2. Technical explanation of the procedure
The device uses a lateral flow chromatographic immunoassay for the semi-quantitative detection of human C-reactive protein. Specific antibodies against CRP are immobilised on the reactive membrane of the cassette: the diluted sample migrates by capillary action and, depending on the CRP concentration present, a pattern of coloured lines is generated which is compared visually with the range table on the packaging (typically below 10, 10-40, 40-80 and above 80 mg/l). The control line (C) always validates the correct performance of the assay.
Summary procedure: (1) Allow the kit to equilibrate to room temperature (15-30 °C). (2) For finger-prick blood, fill the capillary (approx. 10 µl) and transfer it to the tube with buffer solution; for serum or plasma, transfer the sample with the transfer pipette and mix. (3) Add 3 drops of the diluted sample to the well (S) of the cassette. (4) Read the result at 5 minutes; do not interpret after 8-10 minutes. (5) Compare the lines with the scale to obtain the semi-quantitative CRP range.
3. Technical Specifications
The general characteristics, kit contents, packaging and clinical data of the product are detailed below, preserving the original technical data sheet information.
| General characteristics | |
|---|---|
| Analyte detected | C-reactive protein (CRP), semi-quantitative detection |
| Method | Lateral flow immunochromatography |
| Sample type | Whole blood, serum or plasma |
| Format | Individual single-use test cassette |
| Reading time | 5 minutes (do not interpret after 8-10 minutes) |
| Indicative ranges | Below 10 · 10-40 · 40-80 · above 80 mg/l |
| Use | In vitro diagnostic for professional use (TROD) |
| Storage | Room temperature 2-30 °C, protected from moisture and direct sunlight |
| Required material (not provided) | Centrifuge and timer |
| CE declaration of conformity | |
|---|---|
| Available on request |
| Packaging | |
|---|---|
| Units | 10 tests per box |
| Quantity per carton | 80 boxes // 800 tests |
| Dimensions | 67 × 37 × 30 cm |
| Weight | 13 kg/carton |
| Box contents | |
|---|---|
|
| Required material (not provided) | |
|---|---|
|
| Clinical data | |
|---|---|
| Clinical sensitivity | 99.9 % |
| Clinical specificity | 97.5 % |
| Accuracy | 97.8 % |
4. Equivalences and Cross-References
The CRP Semi-Quantitative Rapid Test (CCR-U402) is part of the international family of lateral flow immunochromatographic cassettes for the semi-quantitative detection of C-reactive protein in whole blood, serum or plasma, all based on the same principle and with comparable reading scales (below 10 / 10-40 / 40-80 / above 80 mg/l). Equivalent devices on the market include:
- ABT-INF-B318 – Accu-Tell CRP Semi-Quantitative Rapid Test Cassette (AccuBioTech), with ranges 10/40/80 mg/l and reading in 5 minutes.
- CRP3-13C20 – Rapid Response C-reactive Protein Test Cassette Tri Line (BTNX), presentation of 20 tests, reading in 5 minutes.
- CRPC3L – C-Reactive Protein Rapid Test Cassette (SureScreen Diagnostics), cassette format for whole blood, serum or plasma.
- Equivalent cassettes from DIAQUICK (Alpha Labs), Citest Diagnostics, Healgen and nal von minden (CrP cassette test), with an identical detection principle.
This equivalence facilitates supply approval in purchasing centres and technical comparison between suppliers, maintaining the same clinical performance and reading times.
5. Selection tips and variants of interest
- Professional use: indicated for pharmacies, medical practices, paediatrics, emergency departments and clinical laboratories; it is not a home self-test and should be used as an aid to diagnosis together with clinical assessment.
- Differential diagnosis: low CRP levels point towards a viral aetiology, while marked and sustained elevations suggest a bacterial origin; complement with a full blood count or other markers (PCT) in the event of doubtful results.
- Confirmation of results: in the event of positive or doubtful results, confirmation is recommended by quantitative laboratory determination (turbidimetry, nephelometry or automated immunoassay), especially in at-risk patients.
- Volume and cost per determination: the presentation of 10 tests per box (800 tests per carton in 80 boxes) optimises the cost per test and storage in centres with medium demand; request special conditions for full-carton orders through our commercial team.
- Storage: keep the cassettes in their sealed packaging between 2 and 30 °C, protected from humidity and direct sunlight; do not freeze and respect the indicated expiry date.
- Catalogue universe: complete your point-of-care panel with other Cahnos rapid diagnostic tests from the same diagnostic family, such as inflammation and bacterial infection tests and multiplex respiratory panels, to cover the main aetiologies in a single sample collection.