Description
1. Commercial Introduction
The SpO₂ pulse oximeter sensor adult/neonatal wrap type (reference 35276) is the reference replacement and consumable for departments that monitor blood oxygenation with Philips monitors. Thanks to its multi-position wrap design and 1.6 m cable, it covers two critical patient populations with a single solution: adult patients and neonates. Designed for ICU, neonatology, emergency, operating theatre, delivery room and general hospitalisation, it allows continuous and stable monitoring with a single sensor model in stock. It is an OEM component compatible with Philips, supplied with multilingual manual (GB, FR, IT, ES).
2. Technical explanation of the procedure
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed and a photodetector quantifies the differential absorption according to the degree of blood oxygenation. The signal is transmitted to the Philips monitor via the connector and 1.6 m patient cable.
This wrap type sensor (wrap-around) is multi-position: it can be placed on the finger in adults and on the hand or foot in neonates, making it a versatile solution for ward, emergency and neonatology. The wrap design ensures good optical contact and stable fixation during continuous monitoring, reducing motion artefacts and improving signal reliability.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 35276 |
| Sensor type | SpO₂ pulse oximeter sensor wrap type adult/neonatal |
| Patient population | Adults and neonates |
| Cable length | 1.6 m |
| Compatibility | Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8 |
| Documentation | Multilingual manual included (GB, FR, IT, ES) |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100511 |
4. Equivalences and Cross-References
This product (SKU Cahnos GM35276) corresponds to reference 35276, an OEM sensor compatible with the pulse oximetry connection standard of the cited Philips monitors. We do not have a 1:1 equivalence table validated by the manufacturer that cross-references this reference with codes from other brands; before replacing sensors in a facility, always confirm the exact brand and model of the monitor and the installed connector.
5. Selection tips and variants of interest
Verify compatibility before placing the order: always indicate the brand and model of the Philips monitor (M3, M4, MP20–MP80 or VM4, VM6, VM8) to confirm the fit of the connector and the pulse oximetry protocol. This sensor covers both adults and neonates; if your department works with separate populations, within the Cahnos catalogue you will find other families of SpO₂ sensors by population (adult, paediatric, infant and adult/neonate with DB9 connector compatible with Nellcor systems). For institutional orders, supply contracts or complete monitoring fleets, consult our technical-commercial team to confirm exact compatibility and best volume conditions.





Reviews
There are no reviews yet.