We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable Y-type Ear Lobe SpO2 Pulse Oximeter Sensor for Palmcare | 1.5 m Cable – Ref. 21.13-5257 (APK Technology)

69,00 €

Reusable Y-type ear lobe SpO2 pulse oximetry sensor, for continuous, non-invasive monitoring of oxygen saturation and pulse rate in adults and children. Original spare part from APK Technology (via medical ECONET), compatible with the hand-held pulse oximeters of the Palmcare series: DUOM800, M850, M860, M880, M8500 and Q5. It features an integrated 1.5 m cable and a Y-type shunt connector, which ensures a comfortable and stable attachment to the ear lobe, a measurement point with good perfusion and low sensitivity to movement. Manufacturer ref.: 21.13-5257 / MEC21.13-5257. Product from the pulse oximetry accessories category; sold on quotation. Verify the exact brand and model of your Palmcare monitor before placing the order.

International shipping. Import duties and taxes are payable by the recipient.

Reference
MEC21.13-5257

Description

1. Introduction

The Y-type ear lobe SpO2 pulse oximeter sensor (ref. 21.13-5257) is the reference spare part and accessory for the hand-held pulse oximeters of the Palmcare series. Designed by APK Technology and distributed through medical ECONET GmbH, it allows you to replace or expand the measurement capacity of your device with full guarantees of compatibility and signal stability.

Its Y-type geometry adapts to the ear lobe of adult and paediatric patients, offering a comfortable, stable measurement point with good perfusion, particularly useful when the finger is not a reliable location (movement, low peripheral perfusion or oedema). With an integrated 1.5 m cable, it comfortably covers most bedside, healthcare transport and consultation configurations.

2. Technical explanation of the equipment

Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry: the sensor emits red and infrared light through the vascular bed and a photodetector quantifies the differential absorption depending on the degree of blood oxygenation. The pulsatile component of the signal, generated by the arterial beat, allows real-time calculation of the saturation percentage and heart rate.

This reusable ear lobe sensor follows the electrical and connection scheme specific to the Palmcare family (DUOM800, M850, M860, M880, M8500 and Q5). The Y-type shunt connector ensures correct electrical and functional integration with the monitor, while the attachment to the ear lobe reduces motion interference and provides a stable signal during continuous patient monitoring.

3. Technical Specifications

Product data
Manufacturer / brand APK Technology
Original distributor medical ECONET GmbH
Manufacturer reference 21.13-5257 / MEC21.13-5257
ECONET category Diagnostics/Therapy | Pulse oximetry | Accessories
Presentation 1 unit
Sensor features
Sensor type Y-type ear lobe SpO2 pulse oximeter
Use Reusable
Patient population Adults and children
Measured parameters SpO2 (oxygen saturation) and pulse rate
Cable length 1.5 m
Compatibility Palmcare DUOM800, M850, M860, M880, M8500 and Q5
Available references
Reference Description
21.13-5257 Y-type ear lobe SpO2 sensor for Palmcare (this product)
MEC21.13-5257 Cahnos management code for the same sensor

4. Equivalences and Cross-References

This sensor is the replacement accessory intended by the manufacturer for the Palmcare hand-held pulse oximeter family (DUOM800, M850, M860, M880, M8500 and Q5). There is no manufacturer-validated equivalence table cross-referencing this reference 1:1 with codes from other manufacturers; before any substitution, always verify the exact brand and model of your monitor and the connection scheme with our technical-commercial department.

Within the Cahnos catalogue, the hand-held pulse oximeters of the PalmCare Pro range (refs. 40.50-2240 and 40.50-2300) use reusable catheters from this family of SpO2 accessories; the Y-type catheter for newborns from the same range (family 41.20-5264) shares the connector format, although this must be verified field by field before substitution.

5. Selection tips and variants of interest

Compatibility check: confirm that your monitor corresponds to the Palmcare DUOM800, M850, M860, M880, M8500 or Q5 series before placing the order.

Measurement point: the attachment to the ear lobe is ideal for patients in whom the finger does not provide a stable signal. For other locations or populations, consider the other reusable SpO2 sensors from the Palmcare family available in the catalogue.

Cable reach: the integrated 1.5 m cable covers most monitoring stations; if you need a greater distance to the monitor, consult the extension accessories and SpO2 adapters in the range.

Maintenance: as this is a reusable sensor, clean the outer surface with a soft, dry or slightly damp cloth; do not immerse or autoclave the product, and store it in a dry place protected from direct sunlight.

For institutional orders, supply contracts or compatibility queries, contact the technical-commercial team at Cahnos.

Additional information

Manufacturer

APK Technology (via medical ECONET GmbH)

Manufacturer reference

21.13-5257 / MEC21.13-5257

Sensor type

Y-type ear lobe SpO2 pulse oximeter sensor

Cable length

1.5 m

Compatibility

Palmcare DUOM800, M850, M860, M880, M8500, Q5

Measured parameters

SpO2 (oxygen saturation) and pulse rate

Tipo paciente

Adult, Paediatric

Tipo uso

Reusable

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Reusable Y-type Ear Lobe SpO2 Pulse Oximeter Sensor for Palmcare | 1.5 m Cable – Ref. 21.13-5257 (APK Technology)”

Your email address will not be published. Required fields are marked *