Description
1. Introduction
The 9-pin SpO₂ pulse oximeter sensor (Ref. 18634) is the reference consumable for departments that monitor blood oxygenation with equipment compatible with Nellcor/Oxismart technology. Its 9-pin connector (DB9) ensures direct, secure integration with most bedside, transport and multiparameter monitors that use this standard, covering two critical patient populations with a single stock item: adults and newborns.
Supplied in a box of 25 single-use per patient units, it is designed for hospitals, clinics, emergency departments, intensive care units, operating theatres and neonatal areas that need to maintain a constant turnover of sensors with an adjusted cost per unit and immediate availability, eliminating the risk of cross-contamination between patients.
2. Technical explanation
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry: the sensor emits red light (660 nm) and infrared light (905 nm) through the vascular bed and detects differential absorption according to the degree of blood oxygenation. The signal is transmitted to the monitor through the 9-pin connector (DB9), which follows the electrical scheme of the Nellcor/Oxismart standard.
This multi-site sensor can be placed on different anatomical areas depending on the patient — finger or foot in adults and newborns — making it a versatile solution for wards, emergency departments and neonatology. As a single-use per patient component, it facilitates stock rotation in high-demand units and simplifies service logistics.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Sensor type | Multi-site SpO₂ pulse oximeter sensor |
| Technology / Compatibility | Nellcor systems (Nellcor/Oxismart protocol), 9-pin DB9 connector |
| Connection | 9-pin (DB9) |
| Patient population | Adults and newborns (profile comparable to original Nellcor reference <3 kg and >40 kg) |
| SpO₂ measurement range | 35–100 % (reference value of the Nellcor DB9 family; confirm in batch IFU) |
| SpO₂ accuracy | ≤ 3 % in range 70–100 % (ISO 9919 / ISO 80601-2-61, reference value) |
| Pulse rate range | 30–250 ppm (reference value; confirm in batch IFU) |
| Pulse rate accuracy | ± 2 bpm or ± 2 % (whichever is greater) |
| Wavelength | Red light 660 nm / infrared 905 nm (reference value) |
| Material | Latex-free |
| Sterility | Non-sterile (single-use product per patient) |
| Presentation | Box of 25 units |
| Application | Continuous SpO₂ and pulse rate monitoring in hospitals and clinics |
| Storage | Store in a dry place, protected from direct sunlight and extreme temperatures |
Note: range and accuracy values marked as reference come from technical data sheets of the same family of Nellcor sensors with DB9 connector; always confirm them on the labelling and IFU of the supplied batch.
4. Equivalences and Cross-References
SKU 18634 is Cahnos’ own management code. The following references have been cross-checked against the GUDID/FDA regulatory database, public product documentation and authorised distribution catalogues; none is interchangeable 1:1 with this sensor without prior verification, since the electrical scheme and communication protocol must be confirmed with the specific monitor installed at the facility.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Nellcor (Covidien/Medtronic) | Single-use neonatal-adult SpO₂ sensor | 904-N | Comparable by category (not interchangeable 1:1) | Original sensor from the protocol manufacturer, verified in manufacturer sources and authorised distribution for patients <3 kg and >40 kg, equivalent profile to adults and newborns. Coding and electronics specific to the Nellcor standard; confirm protocol (Oxisensor/OxiMax) with the monitor. |
| Nellcor (Covidien/Medtronic) | Disposable multi-site neonatal/adult Oxisensor II | N-25 | Comparable by category (not interchangeable 1:1) | Disposable multi-site sensor from the original manufacturer (adhesive textile wrap type) with 9-pin DB9 connector and Oxismart technology, widely reproduced by third parties as “N-25 comparable” in authorised distribution. Same patient profile and connector; verify protocol compatibility with each monitor. |
There is no manufacturer-validated equivalence table cross-referencing this sensor with other brands’ codes on a 1:1 interchangeable basis; consult the technical department before using it in tenders. Attention: ear clip sensors in the Nellcor family (e.g. D-HSE, D-YSE) are another type of product, with a different geometry and application site, and must not be confused with this multi-site neonatal/adult sensor.
5. Selection tips and variants of interest
- Choice by patient population: this model covers both adults and newborns; if your department works with separate populations, specific variants of the same family of 9-pin Nellcor sensors are available: adult sensor (SKU 18631), paediatric sensor (SKU 18632) and infant sensor (SKU 18633).
- Compatibility check: although the connector is 9-pin (DB9), the Nellcor protocol has variants (Oxisensor/OxiMax). Always state the brand and model of the monitor to confirm exact compatibility before placing the order.
- Hygiene and storage: as a single-use per patient sensor, it eliminates the risk of cross-contamination. Store in a dry place, protected from direct sunlight and extreme temperatures; do not reuse or reprocess the sensor.
- Cost-effectiveness: the box of 25 units presentation reduces the cost per sensor and ensures continuous stock in high-turnover units. Contact our technical-commercial team for special B2B conditions by volume and supply contracts.