We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable SpO2 Sensor for Nellcor Pulse Oximeter – Neonate 40 kg (Ref. 33755 / GM33755) – Box of 10 units

75,05 €

Disposable pulse oximetry sensor (SpO₂) compatible with Nellcor® equipment: a single model covering two populations. Its neonatal version is placed on the newborn’s foot (40 kg), allowing standardisation of oximetry consumption in neonatology, maternity, emergency and general hospitalisation wards. Each unit is supplied in individual sterile packaging with a 70 cm cable, ready to use and dispose of after each patient, eliminating the risk of cross-contamination. SpO₂ measurement range from 70% to 100% with ±2% accuracy, optical sensor with red light (650–670 nm) and infrared (880–910 nm) and professional presentation in a box of 10 units. Class II B medical device. For large orders you can request a quote.

Sales unit: caja de 10
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33755

Description

1. Commercial Introduction

The disposable SpO₂ sensor (ref. 33755) is the practical and safe solution for continuous monitoring of oxygen saturation in two very common patient profiles: the neonate under 3 kg (placement on the foot) and the adult over 40 kg (placement on the finger). Compatible with monitors and pulse oximeters with Nellcor® connection (except Nellcor Oximax™ technology), this single-use consumable is supplied in sterile packaging with a 70 cm cable, so it is available immediately, hygienically and without any possibility of cross-contamination between patients. An ideal choice for maternity, neonatal units, emergency departments, hospital wards, outpatient clinics and diagnostic centres.

2. Technical Explanation

Pulse oximetry non-invasively measures blood oxygen saturation (SpO₂) and pulse rate by means of the difference in absorption of red light (650–670 nm) and infrared light (880–910 nm) through the vascular bed. This disposable optical sensor incorporates both emitters with powers of 6.65 mW and 6.75 mW respectively, and its dual design allows the application area to be adapted according to the patient’s weight: on the neonate’s foot (40 kg). Being single-use and supplied sterile, traceability and maximum hygiene are guaranteed in each measurement. It is not compatible with Nellcor Oximax™ technology.

3. Technical Specifications

Technical data verified according to the manufacturer’s catalogue:

Parameter Specification
SpO₂ measurement range 70 % ~ 100 %
SpO₂ accuracy 70 % ~ 100 % ±2 %; below 70 %: not specified
Pulse measurement range 30 ~ 250 bpm
Pulse accuracy ±2 bpm or 2% (whichever is greater)
Optical sensor – red light Wavelength 650~670 nm, 6.65 mW
Optical sensor – infrared light Wavelength 880~910 nm, 6.75 mW
Target population Neonate <3 kg (foot) and adult >40 kg (finger)
Compatibility Nellcor® (not compatible with Nellcor Oximax™)
Presentation Individual sterile packaging with 70 cm cable

Product data

Manufacturer GIMA
Manufacturer reference 33755
SKU Cahnos GM33755
Sales unit Box of 10 units (box of 10 pcs)
Device type Medical device (Medical device)
Device class II B
CND C900301
EAN 6945040104346

Available references

Reference SKU Cahnos Description Sales unit
33755 GM33755 Disposable SpO₂ sensor for neonates (<3 kg, foot) and adults (>40 kg, finger) compatible with Nellcor® Box of 10 units

4. Equivalences and Cross-References

The manufacturer’s original reference is 33755 (.), which corresponds to SKU GM33755 on Cahnos. No validated 1:1 equivalence table of this sensor with codes from other manufacturers is available from reliable sources, so no equivalent third-party references are given. The compatibility verified by the manufacturer is limited to equipment with Nellcor® connection (excluding Nellcor Oximax™ technology); before replacing any pulse oximetry consumable, always confirm the connector and measurement system of your monitor with our technical-commercial department.

5. Selection tips and variants of interest

Check the connection system of your pulse oximeter or monitor: this sensor is compatible with conventional Nellcor® technology and not with Nellcor Oximax™. Select the application area according to the patient’s weight: neonate’s foot for those under 3 kg and adult’s finger for those over 40 kg. As it is a single-use product supplied in sterile packaging, use a new unit per patient and check the integrity of the packaging before opening it. Its presentation in a box of 10 units is the most efficient option for services with high monitoring turnover. For volume orders, hospital supplies or technical advice, contact the Cahnos team. For large orders you can request a quote.

Additional information

Manufacturer reference

33755

Product type

Disposable SpO2 sensor (pulse oximetry)

Target population

Neonate 40 kg (finger)

Compatibility

Nellcor (not compatible with Nellcor Oximax)

SpO2 range

70% ~ 100%

Spo2 accuracy

70% ~ 100% ±2%; below 70%: not specified

Pulse range

30 ~ 250 bpm

Pulse accuracy

±2 bpm or 2% (whichever is greater)

Optical sensor

Red light 650~670 nm / 6.65 mW; infrared 880~910 nm / 6.75 mW

Sterilisation

Individual sterile package

Cable

70 cm

Use

Single-use (disposable)

Presentation

Box of 10 units

CND code

C900301

EAN

6945040104346

Presentacion

Box of 10

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateMultilingüe PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable SpO2 Sensor for Nellcor Pulse Oximeter – Neonate 40 kg (Ref. 33755 / GM33755) – Box of 10 units”