Description
1. Introduction
The paediatric SpO2 pulse oximeter probe (ref. 35215) is the ideal spare and replacement accessory to keep the pulse oximeters and monitors of references 35152 and 35213 operational. It is a reusable sensor specifically designed for the paediatric population of 10 to 40 kg, ensuring stable readings of oxygen saturation (SpO2) and pulse rate in hospitals, paediatric clinics, paediatric practices and emergency and medical transport services.
Being reusable, it reduces the cost per patient compared with disposable probes and simplifies stock management in the department, while maintaining the measurement reliability inherent to sensors. It is the right part both as a replacement for a worn probe and to expand the accessory set of your pulse oximeter.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin (SpO2) and pulse rate by spectrophotometry. The probe emits light at two wavelengths (red and infrared) through the patient’s vascular bed; a photodetector quantifies the differential absorption of light according to the degree of blood oxygenation and transmits the signal to the monitor, which processes and displays the values in real time.
This paediatric probe is sized and configured for patients from 10 to 40 kg, with an application point adapted to paediatric anatomy that allows comfortable and stable positioning during continuous monitoring. As it is a reusable model, it must be cleaned between patients following the manufacturer’s instructions and its condition checked periodically to ensure signal quality. The connection is direct with the pulse oximeters of references 35152 and 35213, for which it is specifically indicated.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Sensor type | Paediatric SpO2 pulse oximeter probe |
| Patient population | Paediatric, 10-40 kg |
| Use | Reusable |
| Compatibility | Pulse oximeters and monitors refs. 35152 and 35213 (Oxy family) |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
| Application | Continuous non-invasive monitoring in paediatrics |
| Manufacturer reference | 35215 |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040105695 |
Note: For large orders you can request a quote: ask our technical-commercial department for terms.
4. Equivalences and Cross-References
Ref. 35215 is the factory code for the reusable paediatric SpO2 probe for pulse oximeters 35152 and 35213. The manufacturer uses sensors with proprietary connectors by equipment family, so there is no manufacturer-validated equivalence table cross-referencing this probe with codes from other brands on a 1:1 interchangeable basis. Before any replacement, compatibility with the brand and model of monitor installed at the centre must always be confirmed.
Within the range itself, the family of reusable paediatric SpO2 probes includes other references for different pulse oximeters from the manufacturer, such as the paediatric rubber probe for OXY-10 (refs. 35095/35097) or the paediatric 10-40 kg probe for OXY-100 (refs. 35100/35101). These probes are similar in category and target population, but they are not interchangeable with each other without verifying the connector and the equipment model.
5. Selection tips and variants of interest
Check the model of your pulse oximeter: this probe (ref. 35215) is the one specifically indicated for equipment refs. 35152 and 35213. Always provide the full reference of your monitor to confirm compatibility before placing the order.
Choose the correct population: for paediatric patients of 10-40 kg this is the indicated probe. For other populations or equipment in the same family, specific adult, paediatric and neonatal probes are available in the catalogue: contact us to select the exact reference according to your pulse oximeter.
Maintenance of the reusable probe: clean the sensor surface between patients according to the manufacturer’s instructions, check the cable and connector periodically and replace the probe at any sign of deterioration or unstable reading.
Spare parts management: we recommend keeping a spare probe to avoid interruptions in monitoring. Contact our technical-commercial team for B2B terms, supply contracts and volume sales.





Reviews
There are no reviews yet.