Description
1. Commercial Introduction
The reusable ear clip sensor (ref. 35081) is the ideal replacement and expansion solution to keep your Nonin PalmSAT 2500A handheld pulse oximeter (ref. 35086) operational. It is an ear clip type sensor that is placed on the patient’s earlobe, a comfortable and stable alternative to the finger probe, very useful when the patient’s hands need to be left free or when a durable fixation is sought during monitoring.
This optional accessory shares the quality warranty of a reference medical device manufacturer and is supplied per unit (1 pc), ready to connect to your equipment and provide a spare unit or a second probe to rotate between patients without interrupting clinical activity.
2. Technical Explanation
Pulse oximetry is a non-invasive optical technique that estimates the functional oxygen saturation of arterial haemoglobin (SpO₂) and pulse rate by spectrophotometry. The sensor integrates light emitters (red and infrared) and a photodetector that analyse the differential absorption of light through the capillary bed; from the pulsatile component of the signal, the pulse oximeter calculates and displays the values immediately.
In the case of the ear clip, the sensor is attached to the earlobe, an area of good perfusion and little movement, which favours a stable signal even during prolonged monitoring. Being a reusable sensor, it can be cleaned between patients following the manufacturer’s hygiene protocols, which reduces the cost per use compared with disposable sensors and ensures continuity of monitoring in clinics, emergency departments, hospital wards and medical transport. The 1-metre cable allows the sensor to be connected to the equipment with comfort and freedom of movement.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Sensor type | Reusable ear clip (ear clip) |
| Measurement point | Earlobe |
| Cable length | 1 m |
| Use | Reusable |
| Compatibility | Nonin PalmSAT 2500A pulse oximeter (ref. 35086) |
| Sales unit | 1 pc |
Product data
| Value | Value |
|---|---|
| Manufacturer | GIMA |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | II B |
| CND | C900301 |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| 35081 (SKU Cahnos: GM35081) | Reusable ear clip sensor for 35086 – 8000Q2 (optional), 1 m cable | 1 pc |
4. Equivalences and Cross-References
Reference 35081 is the reusable ear clip sensor designed for the Nonin PalmSAT 2500A pulse oximeter (ref. 35086), a handheld device from the Nonin range with PureSAT® technology. In the manufacturer’s catalogue nomenclature, reference 8000Q2 is also associated, corresponding to the family of ear clip sensors in the Nonin ecosystem.
No reliable source has been found with a manufacturer-validated equivalence table confirming the 1:1 interchangeability of this sensor with SpO₂ probes from other manufacturers (original Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector type and the electronic protocol of each device. It is recommended to always verify the connector and sensor specifications with our technical department before considering replacement with a sensor from another brand. For the PalmSAT 2500A (ref. 35086), within the same family, the reusable paediatric rubber probe (ref. 35088) and the compatible Nonin finger clip (ref. 35266) are available.
5. Selection tips and variants of interest
Confirm your device model: this sensor is intended for the Nonin PalmSAT 2500A pulse oximeter (ref. 35086); check the connector type before placing the order. The ear clip is especially recommended when the patient’s hands need to be left free or when a stable fixation is sought during monitoring; for paediatric or smaller patients, consider the reusable paediatric rubber probe (ref. 35088, finger 10-19 mm with 1 m cable).
Maintenance: as this is a reusable sensor, follow the manufacturer’s cleaning and disinfection instructions between patients and periodically check the cable and the contact area to avoid erroneous readings. It is recommended to have a spare unit for each pulse oximeter in use to minimise downtime. For large orders you can request a quote: contact our technical-commercial team to confirm exact compatibility, availability and B2B supply conditions.






Reviews
There are no reviews yet.