Description
Reliable neonatal monitoring for your Philips fleet
The neonatal SpO₂ pulse oximeter sensor type “Y” (ref. 35275) is the replacement accessory indicated for maintaining oxygen saturation monitoring in newborns with Philips monitors from the M, MP and VM series. Its wrap-around “Y” geometry adapts to the neonate’s foot or hand, providing stable and comfortable fixation during continuous monitoring, both in neonatology and in paediatric ICU, critical care and intra-hospital transport. An OEM replacement of hospital quality, with the technical-commercial support of Cahnos for the management of consumables and equipment fleets.
Technical explanation of the sensor
Pulse oximetry non-invasively measures the functional oxygen saturation of arterial haemoglobin (SpO₂) by spectrophotometry: the sensor emits red and infrared light through the vascular bed and a photodetector quantifies the differential absorption according to the degree of blood oxygenation, transmitting the signal to the monitor’s SpO₂ module. The neonatal “Y” type format wraps around the application area (foot or hand), ideal for the small anatomies of newborns, minimising motion artefacts and ensuring optimal contact between the emitters and the tissue. Manufactured according to the OEM standard of the catalogue for Philips platforms, it is supplied with instruction manual in Spanish, English, French and Italian (GB, FR, IT, ES).
Technical specifications
SpO₂ pulse oximeter sensor of “Y” configuration for neonatal patients, with 1.6 m cable and connection to Philips monitors. Data verified against the Product_DB.csv catalogue (manufacturer ref. 35275).
| Parameter | Specification |
|---|---|
| Sensor type | Neonatal SpO₂ “Y” type (wrap-around) |
| Manufacturer | GIMA |
| Manufacturer reference | 35275 |
| Cable length | 1.6 m |
| Patient population | Neonatal |
| Compatibility | Philips: M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6, VM8 |
| Catalogue number (catalogue data) | 6 |
| Instruction manual | GB, FR, IT, ES |
Product data
| Field | Value |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6900234100597 |
Equivalences and cross-references
This is an OEM configuration sensor for Philips pulse oximetry platforms, whose compatibility list (M3, M4, MP20, MP30, MP40, MP50, MP70, MP80, VM4, VM6 and VM8) appears in the manufacturer’s own catalogue. In reliable sources consulted, no official 1:1 equivalence table with Philips’s own references or those of other manufacturers has been found for this neonatal “Y” type configuration; therefore, no unverified equivalences are indicated here. Before replacing the sensor of a monitor in service, confirm the equipment model (MP or VM series) and the connection point of the SpO₂ module.
Selection tips and variants of interest
Verify the exact model of the Philips monitor installed in your department (MP, VM or M series) before placing the order; the catalogue declares compatibility with M3, M4, MP20-MP80, VM4, VM6 and VM8. This sensor is intended for the neonatal population: if your department also monitors adult, paediatric or infant patients, consult our technical-commercial team for the SpO₂ sensor variants of the same range available in the Cahnos catalogue. For replacement programmes and continuous supply contracts, contact our technical-commercial department indicating the model and reference of the sensors currently in use; we will confirm compatibility and issue the corresponding quote.





Reviews