Description
1. Commercial Introduction
The radiolucent foam electrode for neonatal monitoring RT 22 LWS (SKU 15082) is a highly reliable disposable consumable, specifically designed for electrocardiographic recording and continuous monitoring of newborns and premature infants. Its diameter of Ø 30 mm, its construction in medical foam and its radiolucent nature make it the ideal choice for neonatal intensive care units, neonatology services, neonatal transport and incubators, as well as for any area where patient monitoring is required without interfering with imaging tests.
It is supplied in a bag of 3 units, with a minimum sale in a box of 300 units, designed for continuous consumption by hospital services and procurement centres. A pre-wired quick-connection format that simplifies the nursing routine and reduces failure points compared with conventional electrodes with lead wires.
2. Technical Explanation
These electrodes act as an interface between the neonate’s skin and the bedside monitor: the foam backing with radiolucent material ensures a gentle but firm fixation on the newborn’s delicate skin, while the conductive sensor element (carbon/Ag-AgCl type on solid gel, depending on batch) guarantees stable, low-impedance signal transmission for a clean, continuous ECG trace.
The integrated cable of 60 cm ends in a 1.55 mm connection socket, commercially known as a 1.5 mm DIN safety socket (DIN 42802), compatible with the lead wires of most ECG monitors with European standard. Its radiolucent nature allows the electrodes to remain in place during X-rays, fluoroscopy and other imaging examinations without generating artefacts or interruptions in monitoring, a critical factor in neonatal patients requiring continuous cardiac monitoring during the examination.
3. Technical Specifications
| Type | Radiolucent foam electrode for neonatal monitoring |
| Model / family | RT 22 LWS |
| Material | Foam (medical foam) and radiolucent material |
| Diameter | Ø 30 mm |
| Cable | 60 cm, pre-wired |
| Connection | 1.55 mm (DIN safety connector type 1.5 mm – DIN 42802) |
| Radiotransparency | Yes, suitable for X-ray and imaging examinations |
| Application | Neonatal ECG monitoring, neonatal ICUs, incubators |
| Use | Single-use (disposable), latex-free |
| Presentation | Bag of 3 units |
| Minimum sales unit | Box of 300 units |
Note: the connection values (1.55 mm) and presentation (3 units/bag, 300 units/box) are copied literally from the distributor’s technical documentation; confirm them with the technical data sheet of the supplied batch. Radiolucency refers to use with planar imaging (X-rays); check the equipment manual for MRI compatibility.
4. Equivalences and Cross-References
This reference belongs to the category of pre-wired, radiolucent neonatal monitoring electrodes with a 1.5 mm DIN socket. After verifying manufacturer catalogues, authorised distribution and regulatory databases (GUDID/FDA), the following cross-references with confirmed codes in public sources are identified. Any comparison between brands must be understood as comparable by category (not interchangeable 1:1): check one by one the backing material, diameter, connector type and monitor lead wire before substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| 3M / Solventum (Red Dot™) | Series 2200, pre-wired radiolucent neonatal electrode, soft cloth 22×22 mm | 2282 / 2282L (GUDID 50707387468557) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID (3M Company, model 2282) and authorised distribution. Cloth backing (cloth) versus foam, smaller surface (22×22 mm), pre-wired radiolucent cable with 1.5 mm DIN socket. Verify connector and monitor lead wire. |
| Cardinal Health (Kendall™) | KittyCat™ Cloth Pre-Wired, neonatal radiolucent | 1051NPSM / 31424743 (GUDID 50192253017357) | Comparable by category (not interchangeable 1:1) | Code confirmed in GUDID and authorised distribution. Cloth 2.5 cm, cable ~60 cm, safety socket 0.060″ (≈1.5 mm DIN), radiolucent. Not foam; verify connector and lead wire. |
| Halbach Medical | Clinical ECG Electrode P22DR (neonatal) | EC849923 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s catalogue and shop: non-woven fabric backing (Vlies) 22 mm, cable 60 cm, DIN 1.5 mm connector, hydrogel, radiolucent and repositionable (VE 3/300/3600). The manufacturer declares it comparable to Red Dot 2282/2269 and Kendall 1051NPSM. |
| FIAB Group | Pre-wired radiolucent neonatal foam series, oval format 23×30 mm | F9058NRM (also F9058N/60 with 60 cm cable) | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: foam backing, 23×30 mm, SSC sensor, 1.5 mm DIN socket, 50 cm cable (F9058NRM) or 60 cm (F9058N/60), radiolucent and neonatal. Oval geometry and slightly smaller surface than Ø 30 mm. |
| Medico Electrodes® | Pre-wired radiolucent neonatal electrode (NEOTECNIA distribution) | MPGBW78RT | Comparable by category (not interchangeable 1:1) | Code confirmed in authorised distribution: cloth backing 22×22 mm, hydrogel, Ag/AgCl sensor, DIN 1.5 mm connector with radiolucent carbon cable, sachet of 3 units. Cloth backing, not foam. |
On the market there are also homologous brands in the category without verifiable public code (e.g. BOENMED). A case to watch is Dormo: the reference KFS-150 (distributed by Telic Group) matches in Ø 30 mm, foam backing, solid gel, 60 cm cable and bag of 3 units, but uses a female connector of Ø 4 mm and is not radiolucent, so it is not interchangeable with this reference nor with the 4 mm variant of the same family Cahnos.
There is no equivalence table validated by the manufacturer that authorises the substitution of original electrodes with third-party patches: the connector, lead wire and patch size are specific to each monitoring platform. Any substitution must be validated against the technical data sheet and instructions for use of the monitor and electrode; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
- Check the connector type of your monitor: this reference uses a 1.55 mm connection (1.5 mm DIN socket). If your lead wire uses a 4 mm connector, request the RT 22 LWF variant of Ø 30 mm with 4 mm connection (SKU 15081) from the same family.
- Choose the diameter according to weight and thoracic surface: for very low birth weight neonates or extreme premature infants, the RT 22 LWS version of Ø 22 mm with the same 1.55 mm connection (SKU 15080) may be considered, which reduces the adhesion area on very delicate skin.
- Radiolucency: if the patient may require X-ray or imaging control during monitoring, this version avoids artefacts without removing the electrode; if imaging is not anticipated, the standard variant of the family with 4 mm connection (SKU 15079 / 15081) may be considered, depending on the monitor fleet. Remember to check the equipment manual for MRI compatibility.
- Single-use and storage: disposable, single-use per patient; store in a dry place and respect the expiry date on the packaging to avoid compromising the conductivity of the adhesive.
- Institutional orders: the minimum box of 300 units is intended for supplying neonatology and ICU departments; for tenders and bids, contact the technical-commercial department of Cahnos to confirm compatibility with your monitor fleet before placing the order.