Description
1. Commercial Introduction
The disposable paediatric ECG electrode FIAB Ref. F2017P is the reference consumable for cardiac monitoring and ECG recording in paediatric patients. Its round format of Ø 42 mm, its foam backing and its liquid conductive gel provide a stable signal, comfortable adhesion and quick placement, adapting perfectly to the chest of the smallest patients. It is supplied in a box of 1,000 units (20 bags of 50 units), making it the ideal high-turnover solution for cardiology, paediatrics, ICU, emergency and purchasing departments looking for a reliable electrode with excellent cost per procedure.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the electrical activity of the heart and transmits it with the least possible distortion. In the paediatric population, the quality of the recording depends on three key factors: firm and comfortable adhesion (the electrode must remain fixed throughout the recording), low contact impedance (provided by the liquid conductive gel) and good stability against patient movement.
The foam backing is lightweight, flexible and moisture-resistant: it protects the gel and the sensor, adapts to the contour of the infant chest and maintains its integrity during the recording. The silver chloride sensor (Ag/AgCl, described by the manufacturer as SSC sensor) ensures a stable contact potential and very low polarisation, reducing motion artefacts. The off-centre snap connection facilitates a firm fit with standard patient cables and improves anatomical adaptation. This is a single-use, disposable product that must be disposed of after each patient and stored in its closed packaging in a dry, cool place.
3. Technical Specifications
Main features of the paediatric ECG electrode FIAB Ref. F2017P, according to the manufacturer’s catalogue:
| Characteristic | Value |
|---|---|
| Reference FIAB | F2017P |
| Product type | Disposable surface ECG electrode |
| Population | Paediatric |
| Electrode size | Ø 42 mm |
| Support material | Foam |
| Sensor | SSC (silver chloride, Ag/AgCl) |
| Gel type | Conductive liquid gel |
| Connection | Off-centre snap press stud |
| Use | Single-use, disposable |
| Packaging | 1,000 units (20 bags of 50 units) |
| Units per box (web) | 1000 |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that authorises a 1:1 cross-reference of the F2017P reference with third-party codes. Any comparison must be understood as comparable by category (disposable foam ECG electrode with gel and snap connection for the paediatric population) and never as interchangeable without prior field-by-field verification of diameter, gel type, connector position and adhesive type.
As comparable paediatric electrodes within the Cahnos catalogue, the following are identified, always pending technical validation before any substitution: the paediatric PE foam electrode with solid gel and snap of Ø 40 mm (ref. GM33370, code FIAB F9060P, bag of 50 units), the oval paediatric foam format with solid gel of Ø 32 x 36 mm (ref. GM33313, code FIAB F9089P-100, box of 2,000 units), the circular paediatric foam electrode of Ø 30 mm with solid gel (ref. 0590016, NM 30 RFI, box of 900 units) and the paediatric foam electrode with conductive paste of Ø 43 mm (ref. BRLF9060P, pack of 50 units). All these options differ in diameter, gel type or presentation, so compatibility with the patient cable of the centre’s monitor fleet must be confirmed before selecting.
5. Selection tips and variants of interest
Before placing the order, check the connector type of the patient cable of your monitor, electrocardiograph or Holter recorder: this electrode features an off-centre snap connection. If your fleet uses crocodile clips or banana connectors, consult the range of electrodes with tab (TAB) and the connection adapters available at Cahnos.
For skin preparation, clean and dry the application area (chest) before placement and avoid creams or oily residues to optimise contact impedance. Keep the bags closed in a dry, cool place, rotate stock on a FIFO basis and respect the expiry date, as the liquid gel may lose conductivity if the packaging is opened or deteriorates. It is a single-use, high-turnover consumable: maintain a minimum stock per monitoring station. For complete fittings, tenders or bids, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection of your cables.





Reviews