Description
1. Commercial Introduction
The Ambu BlueSensor R electrodes (Cahnos references GM33208 and GM33209) are the reference solution for obtaining electrocardiograms during exercise stress testing and ergometry. Manufactured by the Danish brand Ambu, these disposable electrodes combine a comfortable foam backing, a highly conductive wet gel and a superior quality Ag/AgCl sensor, providing accurate readings from the first seconds of recording. Their round 57 x 48 mm format with offset connector and reinforced adhesion minimise false alarms and detachment problems, even under intense sweating during exercise. They are supplied in a box of 500 units (20 bags of 25 pieces). For large orders, you can request a quote.
2. Technical Explanation
A surface ECG electrode acts as an interface between the patient’s skin and the monitor or recorder of the exercise stress test: it captures the electrical activity of the heart and transmits it with the least possible distortion. The quality of the recording depends on adhesion (the electrode must remain fixed throughout the study), conductivity (low skin-electrode contact impedance) and stability against movement.
The Ambu BlueSensor R is designed with a highly conductive wet gel that provides immediate signal acquisition and excellent conductivity throughout the recording, without the need for prior skin preparation. Its flexible and comfortable foam backing adapts to the contour of the chest, while the high-quality Ag/AgCl sensor and its large measurement area guarantee a precise and stable signal. The offset connector facilitates fitting with patient cables of ergometers and monitors, and the assembly reduces the movement artefacts typical of ergometry. It is a class I medical device, single-use and non-radiotransparent.
3. Technical Specifications
Main features (Ref. GM33208 · 4 mm connection – Ref. GM33209 · Snap connection)
| Parameter | Specification |
|---|---|
| Brand | Ambu |
| Manufacturer | GIMA |
| Description | BlueSensor R |
| Application | Exercise stress test (ergometry) |
| Gel type | Highly conductive wet gel |
| Backing material | Foam |
| Measurements | 57 x 48 mm |
| Shape | Round with offset connector |
| Sensor | High-quality Ag/AgCl |
| Connector type | 4 mm (GM33208) / Snap (GM33209) |
| Radiolucent | No |
| Shelf life* | 24 months |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | C020501 |
| GMDN | 35035 |
*Shelf life indicates the maximum duration from the production date. The average shelf life is 50% to 90% of the maximum duration.
Available references
| Reference | Connection | Sales unit |
|---|---|---|
| GM33208 | 4 mm | Box of 500 pcs. (box of 500 units) |
| GM33209 | Snap | Box of 500 pcs. (box of 500 units) |
Internal equivalences in the manufacturer’s catalogue
| Reference Cahnos | Ambu code | Connection | Presentation |
|---|---|---|---|
| GM33208 | R-00-A/25 | 4 mm | 20 bags of 25 units (box of 500 units) |
| GM33209 | R-00-S/25 | Snap | 20 bags of 25 units (box of 500 units) |
4. Equivalences and Cross-References
The Ambu BlueSensor R family shares technology and typology with other wet gel electrodes for exercise stress testing and monitoring. Within the manufacturer’s own catalogue, the equivalent Ambu codes are R-00-A/25 (4 mm connector) and R-00-S/25 (snap connector), the latter variant also being referenced on the market as R-00-S or R-00-S/5. In the Cahnos catalogue, comparable electrodes by category for exercise stress testing and monitoring (not interchangeable 1:1, requiring validation of connector, gel and geometry) include the references ST 50 RFI (Cahnos 0590028), ST 50 RLI (Cahnos 0590024), NM 50 RFI (Cahnos 13628), FS 501 S (Cahnos 11322) and the radiotransparent versions RT 50 RFI (Cahnos 0590022) and F 50 S BLUE (Cahnos 15843). Field-by-field verification of measurements, gel type, connector position and radiotransparency is essential before any substitution; consult the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Check the connector of your system before ordering: the BlueSensor R electrode is available with a 4 mm connector (Ref. GM33208) for cables compatible with 4 mm banana terminals and with a snap connector (Ref. GM33209) for the standard of patient cables of ergometers and monitors. Check the forceps or cable of your monitor fleet and choose the corresponding variant. This electrode is the optimal choice for exercise stress testing thanks to its fast-acquisition wet gel and reinforced adhesion; if your service performs prolonged monitoring (Holter) or recordings with extreme sweating, consider solid gel alternatives from the same family at Cahnos. Keep the bags closed in a dry, cool place, rotate stock under FIFO criteria and respect the shelf life indicated on the packaging to avoid compromising the conductivity of the gel. For volume orders, complete supplies or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the type of connection.