Reusable connection cable for concentric EMG needles, 100 cm, 5-pin DIN connector – compatible with Cadwell and other electromyographs (Ref. F8995/NI)

Original price was: 59,40 €.Current price is: 47,55 €.

Reusable 100 cm connection cable for concentric needle electrodes with 5-pin DIN connector, compatible with electromyography equipment Cadwell (all models), as well as with electromyographs Nihon Kohden, Natus (Keypoint), EB Neuro (Myto), Carefusion (Medelec, Synergy, Nicolet, Viking) and Micromed. Designed for the F8990/F8990PD series electrodes, it ensures stable, shielded and interference-free signal transmission in EMG studies, electroneurography and neurophysiological tests. High-durability accessory for clinical, hospital and neurodiagnostic laboratory use.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F8995/NI

Description

1. Product Presentation

The 5-pole DIN concentric needle electrode connection cable (Ref. F8995/NI) is the ideal accessory for connecting your concentric needle electrodes to the electromyograph. With a length of 100 cm and a 5-pole DIN connector, it is specifically designed for the F8990/F8990PD series electrodes and is fully compatible with Cadwell equipment (all models), as well as with other commonly used electromyographs on the market such as Nihon Kohden, Natus (Keypoint), EB Neuro (Myto), Carefusion (Medelec, Synergy, Nicolet, Viking) and Micromed. A single cable that resolves the connection of concentric needles in most electromyography equipment in hospital settings.

2. Technical explanation of the equipment and procedure

In an electromyography (EMG) study, the concentric needle records the electrical activity of muscle fibres by inserting a fine electrode into the muscle. The needle electrode consists of a central wire (cathode) and an outer cannula (anode) separated by an insulating material; the captured signal is of very low amplitude (on the order of microvolts) and requires shielded, low-impedance transmission to avoid electrical noise and artefacts that distort the trace.

This cable acts as an interface between the needle electrode and the equipment socket: the distal end attaches to the electrode connector (lead wire) and the proximal end terminates in a 5-pole round DIN connector (DIN 45322) that connects to the amplifier input of the electromyograph. The cable is reusable, of robust construction and with shielding that guarantees an optimal signal-to-noise ratio in EMG studies, electroneurography (NCS) and other neurophysiological tests, both in routine examinations and prolonged studies.

3. Technical Specifications

Specification Value
Product type Reusable connection cable for concentric needle electrodes
Reference F8995/NI
Connector 5-pole round DIN (DIN 45322)
Cable length 100 cm
Compatible electrodes F8990 / F8990PD series (concentric needles with separable lead wire)
Equipment compatibility Cadwell (all models), Nihon Kohden (all), Natus (Keypoint), EB Neuro (Myto), Carefusion (Medelec, Synergy, Nicolet, Viking), Micromed
Application EMG, electroneurography (NCS) and neurophysiological tests
Use Reusable · clinical, hospital and neurodiagnostic laboratories
Shielding Shielded cable for stable signal transmission and low interference

4. Equivalences and Cross-References

The reference F8995/NI is an own distribution code, internally documented as a 100 cm cable with a 5-pole DIN connector for concentric needle electrodes compatible with a wide range of electromyographs. Below are references from other manufacturers verified against primary sources (official manufacturer website and GUDID/FDA regulatory database) with the same function; there is no equivalence table validated by the manufacturer declaring them 1:1 interchangeable, so they should be treated as comparable at category level.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cadwell Reusable connection cable for concentric needles (detached lead) with 5-pole DIN connector 202462-000 (1.25 m) · 202463-000 (2.0 m) Comparable by category (not interchangeable 1:1) Same function: reusable shielded cable with 5-pole DIN connector for Cadwell concentric needle electrodes. Differs in length (125 cm / 200 cm vs. 100 cm) and the design of the electrode coupling socket. Code and attributes verified on the official Cadwell eStore.
Ambu Ambu® Neuroline™ Concentric Cable (5-pin DIN) 1741 (100 cm) · 1742 (200 cm) Comparable by category (not interchangeable 1:1) Reusable shielded cable with DIN connector (standard 60130-9), latex-free, for Neuroline concentric needles. Differs in the electrode coupling system (Ambu free orientation) and available length. Code and attributes verified in official Ambu catalogue and authorised distribution.
LifeSync Reusable Cable for Concentric Needles (5-Pole DIN plug) NC-850125 (1.25 m) · NC-850200 (2.0 m) Comparable by category (not interchangeable 1:1) Reusable 5-pole DIN connector cable for concentric needle electrodes, for EMG/NCS configuration with separable lead wire. Differs in length (125/200 cm vs. 100 cm) and the intended electrode manufacturer. Verified on LifeSync product sheet.
Rochester Electro-Medical Reusable shielded cable, 5-pole DIN, for concentric needle and single fibre electrode GUDID registered device 00849593025300 (1.25 m / 4 ft) Comparable by category (not interchangeable 1:1) Reusable shielded 5-pole DIN cable for concentric needle and single fibre (single fiber) electrodes. They differ in length and regulatory registration (US market). Verified on GUDID/FDA regulatory database (Rochester Electro-Medical, Inc.).

There is no equivalence table validated by the manufacturer that cross-references the F8995/NI reference with codes from other brands; consult the technical department before use in tenders. Before any substitution, check field by field: pin configuration (5-pole DIN vs. 3-pole microconnector), cable length, electrode coupling system (separable lead) and compatibility with the installed electromyograph socket.

5. Selection tips and variants of interest

Choose the cable according to your electromyograph socket: the Ref. F8995/NI (5-pole DIN, 100 cm) is the universal option for Cadwell, Nihon Kohden, Natus (Keypoint), EB Neuro (Myto), Carefusion (Medelec, Synergy, Nicolet, Viking) and Micromed equipment. For EB Neuro Myto2, Nemus and Nemus2 equipment, the specific variant F8995/EN (5-pole DIN) can be ordered, and for Micromed systems with ISA Headbox, the variant F8995/MM (3-pole microconnector).

Complete the set with the concentric needles from the F8990/F8990PD series: choose the gauge and length according to the muscle to be examined (for example, diameters from 0.35 to 0.50 mm and lengths from 20 to 60 mm, in sterile single-use and non-sterile reusable presentations), always with separable lead wire to attach to this cable.

Maintenance of the reusable cable: clean the outer surface according to the device reprocessing instructions and avoid autoclave sterilisation unless expressly indicated by the cable manufacturer. Periodically inspect the DIN connector and the shielding; if any sign of deterioration is observed, replace the cable to avoid compromising signal quality.

For institutional volumes, tenders or specific length requirements (e.g. 1.25 m or 2 m), please contact our technical-commercial team at Cahnos, who will advise you on the most suitable variant for your equipment fleet.

Additional information

Reference

F8995/NI

Product type

Reusable connection cable for concentric needle electrodes

Connector

5-pole round DIN (DIN 45322)

Cable length

100 cm

Application

EMG, electroneurography (NCS) and neurophysiological tests

Compatible electrodes

F8990 / F8990PD series (concentric needles with separable lead wire)

Compatibility

Cadwell (all models), Nihon Kohden, Natus (Keypoint), EB Neuro (Myto), Carefusion (Medelec, Synergy, Nicolet, Viking), Micromed

Shielding

Shielded cable for stable signal transmission and low interference