Description
1. Commercial Introduction
The patient ECG cable FIAB F8751 is a high-quality replacement designed for continuous electrocardiographic monitoring in hospital and intermediate care settings. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European leader in electrocardiography accessories, this cable without distributor (without manifold) connects directly to the electrodes via snap-type terminals and is compatible with Mortara devices. It is the practical solution for renewing the wiring of your bedside monitors, central stations and care units, ensuring a stable, clean and reliable ECG signal. Distributed by Cahnos on order and without public price (sale on quotation).
2. Technical Explanation
The patient cable is the interface element between the ECG electrodes placed on the patient’s chest and the monitor: through it, the cardiac electrical signals captured by the electrodes are transmitted to the monitoring equipment for amplification, filtering and display. This model without distributor (without lead box or manifold) consists of a bundle of cables that terminate directly in snap-type connectors, ready to attach to single-use electrodes with a button connector. This configuration simplifies handling, reduces weight and facilitates cleaning, while avoiding intermediate connection points that could degrade the signal. The connector at the end of the cable couples to the ECG input of Mortara monitors, maintaining compatibility with the installed equipment platform.
3. Technical Specifications
Main features of reference F8751 from FIAB:
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F8751 |
| Product type | Patient ECG cable without distributor (without manifold) |
| Connection system | Snap (clip / button) |
| Compatible with | Mortara |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
Technical note: always check the number of leads (3, 5, 6 or 12) and the connector of the ECG input on your Mortara monitor to confirm the correct fit of the cable before clinical use.
4. Equivalences and Cross-References
Reference F8751 is the catalogue code from FIAB for this patient ECG cable with snap connection compatible with Mortara. In the Cahnos distribution catalogue, this same unit is identified with the SKU FIAB-F8751. No verified reliable sources provide a 1:1 equivalence table with cables from other manufacturers for this specific platform (snap connection, without manifold, Mortara-compatible): correspondences between third-party cables must always be validated against the manufacturer’s technical data sheet and the monitor’s documentation (IFU) before replacing the original cable. Consult the Cahnos technical department if you need to confirm exact compatibility with the model and serial number of your equipment.
5. Selection tips and variants of interest
First confirm the configuration of your Mortara monitor: number of leads, type of ECG input connector and electrode attachment system (snap). This cable is the variant without manifold with snap connection; if your monitor or workflow requires a cable with manifold or with other terminals, FIAB offers other references within its patient cable category — avoid mixing connection systems (snap versus banana or DIN) and check the fit of the connectors before integrating the replacement into your equipment. To periodically renew your monitoring fleet, consider purchasing the spare unit (1 cable per pack) and keep at least one spare available per monitor. If you have any compatibility doubts, provide Cahnos with the exact model and serial number of your Mortara equipment for prior technical verification. Sale on quotation: contact our sales team for prices and lead times.