Description
1. Commercial Introduction
We offer you the ECG patient cable with inspectable manifold and snap connection, reference F5726C/MAC from the Italian manufacturer FIAB SpA (Vicchio, Florence, Italy), a European specialist in electrocardiography and monitoring accessories. This cable is designed to ensure reliable, high-quality transmission of the ECG signal between the patient and the electrocardiograph or monitor, and is compatible with Macquarie equipment. It is supplied as a single unit and sold on a quotation basis, with terms adapted to the volume requirements of hospitals, clinics, health centres and cardiology departments.
2. Technical Explanation
The ECG patient cable is the connecting element between the electrodes placed on the patient and the recording or monitoring equipment. This model incorporates an inspectable manifold (inspectable manifold): a central openable piece that allows visual inspection of the internal connections, solder joints and conductors without having to disassemble the entire cable, facilitating preventive maintenance, early detection of deterioration and extending the service life of the accessory.
The snap (SNAP) connection at the patient end allows rapid, secure attachment of standard button-type disposable electrodes or leads, ensuring a firm mechanical contact and stable contact impedance that prevents interference and artefacts in the electrocardiographic recording. It is a professional-use accessory intended for resting ECG acquisition and for continuous patient monitoring in cardiology, emergency, ICU and outpatient departments.
3. Technical Specifications
Manufacturer specifications verified in the official FIAB catalogue (section ECG › Patient Cables › Inspectable Manifold › Snap):
| Characteristic | Value |
|---|---|
| Reference FIAB | F5726C/MAC |
| Packaging | 1 unit |
| Units per box (web) | 1 |
| Compatible with | Macquarie |
Additional data identified in the FIAB catalogue:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Manufacturer / original distributor | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | ECG patient cable (ECG patient cable) |
| Distributor type | Inspectable (inspectable manifold) |
| Patient connection | Snap (SNAP) |
| Catalogue category | ECG › Patient Cables › Inspectable Manifold › Snap |
Available references: FIAB-F5726C-MAC and F5726C/MAC.
4. Equivalences and Cross-References
Reference F5726C/MAC corresponds to the official catalogue of manufacturer FIAB and is sold by Cahnos without altering the original code (SKU FIAB-F5726C-MAC). The manufacturer does not publish a validated equivalence table cross-referencing this reference with codes from other suppliers, so no direct 1:1 equivalents are indicated without technical verification.
Within the FIAB family of ECG patient cables with inspectable manifold and snap connection, the following variants are available for other equipment:
| Reference FIAB | Compatible equipment |
|---|---|
| F5726C | Mortara, BTL |
| F5726C/HP | HP |
| F5726C/MAC | Macquarie |
| F5726C/NK33 | Nihon-Kohden |
| F5726C/9 | Siemens, Bosch, Custo Med |
Before any replacement, always verify the connection standard of your equipment and the required connector type; if in any doubt, consult the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
1) Check compatibility: this F5726C/MAC cable is designed for Macquarie equipment; confirm the specific model of your electrocardiograph or monitor before ordering.
2) Required connection: ensure your system works with snap-type (SNAP) leads; if your configuration is different, consider other cable families from the FIAB catalogue.
3) Inspectable manifold: take advantage of periodic inspection of the manifold to check contacts and conductors and detect signs of cable fatigue in time.
4) Other brands: if your equipment fleet includes Mortara, BTL, HP, Nihon-Kohden, Siemens, Bosch or Custo Med, the F5726C family variants can cover those needs with the same design concept.
5) Maintenance: handle the connector carefully when connecting and disconnecting electrodes and avoid sharp pulls on the cable. For quotations, B2B volume terms or supply agreements, contact the technical-commercial team at Cahnos.