We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

ECG patient cable with inspectable manifold and snap (SNAP) connection for Macquarie equipment · FIAB Ref. F5726C/MAC

Price on request

ECG patient cable from Italian manufacturer FIAB SpA with inspectable manifold (inspectable manifold) and type snap (SNAP) connection terminals, specifically designed for Macquarie brand equipment. Its openable distribution box allows inspection and review of internal connections, solder joints and conductors without disassembling the entire cable, facilitating preventive maintenance and extending the service life of the assembly. Presentation of 1 unit. Reference F5726C/MAC. Product sold on quotation: consult our technical-commercial department to confirm exact compatibility with your electrocardiograph or monitor and supply conditions for healthcare facilities.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F5726C-MAC
Brand
FIAB

Description

1. Commercial Introduction

We offer you the ECG patient cable with inspectable manifold and snap connection, reference F5726C/MAC from the Italian manufacturer FIAB SpA (Vicchio, Florence, Italy), a European specialist in electrocardiography and monitoring accessories. This cable is designed to ensure reliable, high-quality transmission of the ECG signal between the patient and the electrocardiograph or monitor, and is compatible with Macquarie equipment. It is supplied as a single unit and sold on a quotation basis, with terms adapted to the volume requirements of hospitals, clinics, health centres and cardiology departments.

2. Technical Explanation

The ECG patient cable is the connecting element between the electrodes placed on the patient and the recording or monitoring equipment. This model incorporates an inspectable manifold (inspectable manifold): a central openable piece that allows visual inspection of the internal connections, solder joints and conductors without having to disassemble the entire cable, facilitating preventive maintenance, early detection of deterioration and extending the service life of the accessory.

The snap (SNAP) connection at the patient end allows rapid, secure attachment of standard button-type disposable electrodes or leads, ensuring a firm mechanical contact and stable contact impedance that prevents interference and artefacts in the electrocardiographic recording. It is a professional-use accessory intended for resting ECG acquisition and for continuous patient monitoring in cardiology, emergency, ICU and outpatient departments.

3. Technical Specifications

Manufacturer specifications verified in the official FIAB catalogue (section ECG › Patient Cables › Inspectable Manifold › Snap):

Characteristic Value
Reference FIAB F5726C/MAC
Packaging 1 unit
Units per box (web) 1
Compatible with Macquarie

Additional data identified in the FIAB catalogue:

Parameter Specification
Brand FIAB
Manufacturer / original distributor FIAB SpA (Vicchio, Florence, Italy)
Product type ECG patient cable (ECG patient cable)
Distributor type Inspectable (inspectable manifold)
Patient connection Snap (SNAP)
Catalogue category ECG › Patient Cables › Inspectable Manifold › Snap

Available references: FIAB-F5726C-MAC and F5726C/MAC.

4. Equivalences and Cross-References

Reference F5726C/MAC corresponds to the official catalogue of manufacturer FIAB and is sold by Cahnos without altering the original code (SKU FIAB-F5726C-MAC). The manufacturer does not publish a validated equivalence table cross-referencing this reference with codes from other suppliers, so no direct 1:1 equivalents are indicated without technical verification.

Within the FIAB family of ECG patient cables with inspectable manifold and snap connection, the following variants are available for other equipment:

Reference FIAB Compatible equipment
F5726C Mortara, BTL
F5726C/HP HP
F5726C/MAC Macquarie
F5726C/NK33 Nihon-Kohden
F5726C/9 Siemens, Bosch, Custo Med

Before any replacement, always verify the connection standard of your equipment and the required connector type; if in any doubt, consult the technical-commercial department of Cahnos.

5. Selection tips and variants of interest

1) Check compatibility: this F5726C/MAC cable is designed for Macquarie equipment; confirm the specific model of your electrocardiograph or monitor before ordering.

2) Required connection: ensure your system works with snap-type (SNAP) leads; if your configuration is different, consider other cable families from the FIAB catalogue.

3) Inspectable manifold: take advantage of periodic inspection of the manifold to check contacts and conductors and detect signs of cable fatigue in time.

4) Other brands: if your equipment fleet includes Mortara, BTL, HP, Nihon-Kohden, Siemens, Bosch or Custo Med, the F5726C family variants can cover those needs with the same design concept.

5) Maintenance: handle the connector carefully when connecting and disconnecting electrodes and avoid sharp pulls on the cable. For quotations, B2B volume terms or supply agreements, contact the technical-commercial team at Cahnos.

Additional information

Brand

FIAB

Packaging

1 unit

Compatibility

Macquarie

Manufacturer

FIAB SpA (Vicchio, Florence, Italy)

Manufacturer reference

F5726C/MAC

Product type

ECG patient cable

Distributor type

Inspectable (inspectable manifold)

Connection

Snap (SNAP)

Units per box

1

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “ECG patient cable with inspectable manifold and snap (SNAP) connection for Macquarie equipment · FIAB Ref. F5726C/MAC”

Your email address will not be published. Required fields are marked *