Description
1. Commercial Introduction
At Cahnos we offer you the ECG patient cable FIAB Ref. F5226C, an accessory of proven quality with inspectable manifold and snap connection, designed for equipment from the brands Cardiorapid, Aspel and Bionet. Manufactured by FIAB SpA (Vicchio, Florence, Italy), a European reference in medical electronics accessories, this cable allows you to maintain the diagnostic quality of your electrocardiograph with a robust, reliable and easy-to-maintain replacement. It is the indicated solution for cardiology practices, emergency departments, primary care centres and functional diagnostic units.
2. Technical Explanation
The ECG patient cable is the element of the recording chain that transmits the cardiac electrical signal captured by the electrodes to the electrocardiograph. The signal travels the following path: electrode (adhesive, suction cup or forceps) → individual lead → cable manifold → equipment connector.
This model incorporates an inspectable manifold (inspectable manifold): a connection box that can be opened to inspect and clean the internal contacts without having to replace the entire cable, which facilitates preventive maintenance and extends the service life of the accessory. The patient-end terminals are of the snap (clip) type, the most common connection system for disposable ECG electrodes: each clip attaches quickly and securely to the electrode button, ensuring a firm mechanical contact and a stable contact impedance during recording.
3. Technical Specifications
The manufacturer’s catalogue specifications are detailed below:
| Characteristic | Value |
|---|---|
| Reference FIAB | F5226C |
| Packaging | 1 unit |
| Units per box (web) | 1 |
Additional data identified in the FIAB catalogue:
| Parameter | Specification |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | ECG patient cable (ECG patient cable) |
| Distributor type | Manifold / inspectable distributor box (inspectable manifold) |
| Patient connection | Snap / clip (CLIP) |
| Compatibility | Cardiorapid, Aspel and Bionet |
| Catalogue category | ECG > Patient Cables > Inspectable Manifold > Snap |
| Presentation | 1 piece per pack |
4. Equivalences and Cross-References
This product corresponds to the factory reference F5226C from FIAB SpA (also registered as FIAB-F5226C in the Cahnos catalogue). The indicated equipment brands, Cardiorapid, Aspel and Bionet, come from the manufacturer’s own catalogue and constitute the verified compatibility list.
No official equivalence table has been found in reliable sources that would allow this F5226C reference to be replaced 1:1 by cables from other manufacturers. ECG patient cables are accessories specific to the connector of each electrocardiograph, so the number of conductors, the terminal type (snap) and the equipment-side connector must always be checked against the electrocardiograph’s technical data sheet before adopting an alternative. Within the Cahnos catalogue there are other patient cables with snap connection compatible with similar equipment — such as those intended for Cardiorapid (Camina-Eurocamina series) or for Bionet —, but each reference must be validated against the specific model of your equipment fleet before any replacement. Consult our technical-commercial department to confirm the appropriate variant.
5. Selection tips and variants of interest
First confirm the exact model of your electrocardiograph: this F5226C reference is indicated for Cardiorapid, Aspel and Bionet equipment. Check the terminal type at the patient end: the snap (clip) connection is compatible with standard button disposable ECG electrodes, and is not interchangeable with forceps or banana systems, so you must choose the variant according to your electrode fleet and the equipment connector.
It is recommended to have a spare cable per workstation to avoid interrupting diagnostic activity during cleaning, maintenance or replacement of the cabling. Take advantage of the inspectable manifold: periodically inspect and clean the internal contacts according to the manufacturer’s instructions for use, and replace the part at any sign of deterioration, loss of signal quality or insulation breakage.
For hospital supplies, mixed fleets or tenders, contact the technical-commercial team at Cahnos to confirm exact compatibility with your equipment and obtain a formalised quotation without obligation.