Description
1. Commercial Introduction
The monitoring electrodes 3M™ RED DOT™ 2238 (reference 33296 / SKU Cahnos GM33296) are disposable single-use consumables, designed for continuous electrocardiographic monitoring in adult patients. Their soft cloth non-woven fabric backing offers a soft, breathable and flexible adhesion that adapts to the thoracic contour, ideal for sensitive skin and for prolonged stays, without compromising the signal stability characteristic of one of the most recognised families of surface electrodes on the market.
They are supplied in a box of 1000 units (20 sachets of 50 units), a high-performance format designed for the continuous supply of cardiology departments, ICU, emergency, hospitalisation units, stress tests and purchasing centres. Being an original 3M electrode, it guarantees trace homogeneity and reliability in every monitoring session.
2. Technical Explanation
The monitoring electrode acts as an interface between the patient’s skin and the monitor or recording device: it captures the electrical activity of the heart and transmits it with the minimum possible distortion. The quality of the trace depends on three key factors: adhesion (the electrode must remain fixed throughout the monitoring), conductivity (low skin-electrode contact impedance) and stability against patient movement.
This model incorporates a backing of non-woven fabric of the soft cloth type with solid gel and removal tab (lift tab): a breathable, flexible and conformable system that adapts to the patient’s anatomy, minimises irritation on sensitive skin and facilitates quick placement and removal. It is radiotransparent, so it does not interfere with imaging studies or radiography, and offers a use duration of up to 3 days. Being single-use, it guarantees hygiene and prevents cross-contamination: each monitoring session starts with a new electrode, with no further skin preparation than prior cleaning and drying.
3. Technical Specifications
Main characteristics
| Characteristic | Value |
|---|---|
| Type | Disposable, single-use monitoring electrode |
| Code 3M | 2238 |
| Diameter | Ø 6 cm |
| Support material | Non-woven fabric, soft cloth type |
| Gel type | Solid gel |
| Removal tab | Yes (lift tab) |
| Use duration | Up to 3 days |
| Population | Adult |
| Application | Continuous ECG monitoring |
| Radiotransparency | Yes |
| Use | Single-use, disposable |
| Presentation | Box of 1,000 units (20 sachets of 50 units) |
Product data
| Brand | 3M |
|---|---|
| Sales unit | Box of 1,000 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
Available references
| Reference / Code | Origin | Description |
|---|---|---|
| 33296 | SKU | 3M RED DOT 2238 – soft cloth monitoring electrodes, Ø 6 cm |
| GM33296 | SKU Cahnos | 3M RED DOT 2238 electrodes – box of 1000 units (20 sachets of 50) |
| 2238 | Code 3M | RED DOT™ family – monitoring electrode with soft cloth fabric and solid gel |
Note: technical data are taken from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tendering.
4. Equivalences and Cross-References
Reference 33296 is the manufacturer’s official code for this 3M RED DOT 2238 electrode. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers should be understood as comparable by category (disposable monitoring electrode with non-woven backing, adult format) and never as interchangeable without verification.
As homologous families in the category, the monitoring electrodes from Skintact (Leonhard Lang), Ambu (WhiteSensor series), Kendall (Cardinal Health) and FIAB can be cited, always pending verification against the official technical data sheet.
Within the 3M™ RED DOT™ family itself, the closest variants are:
| Reference Cahnos | Code 3M | Description |
|---|---|---|
| GM33297 | 2239 | Non-woven fabric electrode with micropore backing, Ø 6 cm, adult |
| GM33299 | 2248-50 | Paediatric non-woven fabric electrode with micropore, Ø 4.5 cm |
| GM33290 | 2228 | Foam electrode with adhesive gel, 3.71 x 3.25 cm |
| GM33291 | 2228BA | Foam electrode with 4 mm adapter, 3.71 x 3.25 cm |
| GM33292 | 2244 | Foam electrode with adhesive gel, 4 x 3.25 cm |
| GM33293 | 2570 | Foam electrode with adhesive gel, 4 x 3.5 cm (up to 5 days) |
| GM33378 | 2330 | Pregelled electrode for resting ECG, 3.2 x 2.2 cm |
Before any substitution, check field by field: diameter, backing material, gel type, target population and compatibility with the monitor’s lead wire connector.
5. Selection tips and variants of interest
Monitoring duration: this soft cloth electrode offers up to 3 days of continuous use, suitable for ICU and hospitalisation. For prolonged monitoring, consider the foam electrodes with adhesive gel from the RED DOT™ family (codes 2228 and 2244).
Backing preference: if your department prefers a non-woven fabric backing with micropore tape instead of soft cloth, consult the 3M RED DOT 2239 variant (ref. GM33297, Ø 6 cm); if you need connection with a 4 mm adapter, the 2228BA variant (ref. GM33291) from the same family.
Paediatric population: for paediatric patients, the RED DOT family offers the 2248-50 electrode (Ø 4.5 cm, ref. GM33299).
Equipment connection: verify the connector type and lead wire of your monitor or electrocardiograph before placing the order, as well as the purchase format (the box of 1000 units is supplied in 20 sachets of 50 units).
Skin preparation: clean and dry the application area (chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeats due to poor signal.
Storage: disposable single-use product; keep boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or deteriorates. For complete supplies or tenders, contact the technical-commercial department of Cahnos.





Reviews
There are no reviews yet.