Description
1. Commercial Introduction
The peripheral forceps electrode F9024NI from FIAB is the reusable and durable solution for recording electrocardiograms in adult patients. Its nickel-plated sensor provides stable signal capture for resting ECG recordings, and its forceps-type design ensures a firm and comfortable grip on wrists and ankles. It is the ideal accessory for cardiology clinics, emergency departments, occupational medicine units and hospitals that need a reliable supply of peripheral electrodes, with the quality guarantee of a reference Italian manufacturer such as FIAB SpA.
2. Technical explanation of the electrode
This is a forceps (clamp) electrode for limbs, of the peripheral type, within the range of reusable electrodes from FIAB. It attaches to the patient’s upper and lower limbs and transmits the electrocardiographic signal to the electrocardiograph or monitor via the patient cable. The contact surface is made with a nickel-plated sensor (nickel plated), the lowest-cost variant in the family, compared with the silver/silver chloride (Ag/AgCl) coated versions that offer superior signal performance. Its reusable nature allows prolonged use with proper cleaning and disinfection following the manufacturer’s instructions, making it an economical option for intensive use.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9024NI |
| Packaging | 4 units |
| Units per box (web) | 4 |
| Parameter | Value |
|---|---|
| Electrode type | Reusable peripheral forceps for ECG (limb electrode) |
| Size | Adult |
| Sensor | Nickel-plated |
| Application | Resting ECG in adult patients, monitoring and clinical studies with compatible cables |
| Manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Presentation | Box of 4 units |
| FIAB range | ECG > Reusable Electrodes > Peripheral > Adult Clamps |
4. Equivalences and Cross-References
The reference F9024NI is confirmed in the manufacturer’s official catalogue (FIAB, Italy) as a peripheral forceps electrode with nickel-plated sensor for adults, in a presentation of 4 pieces. There is no cross-reference equivalence table validated by the manufacturer that associates this reference with codes from other brands interchangeably 1:1; the codes listed below are homologous by function (reusable adult limb forceps for ECG) and are listed for comparison purposes, and sensor, connector, dimensions and regulatory classification must always be verified before any substitution.
| Manufacturer / Brand | Family / Model | Code | Level | Observations |
|---|---|---|---|---|
| FIAB (Italy) | Adult peripheral forceps Ag/AgCl, universal connection | F9024SSC | Same family, sensor variant | Silver/silver chloride (Ag/AgCl) sensor; signal performance superior to nickel-plated |
| Lessa (AB Medica Group, Spain) | Reusable adult ECG electrode forceps | 99.100.00 | Comparable by category | Adult forceps with universal connection; confirm sensor and connector before replacing |
| Moretti S.p.A. (Italy) | Peripheral Clamp Electrodes – Adults | DRV170 | Comparable by category | Ag/AgCl sensor and universal connection; not interchangeable without verification |
| Igibsa (Spain) | Adult forceps electrode for electrocardiograph | 14-EP01 | Comparable by category | Ag/AgCl contact plate, universal connection; verify geometry and presentation |
No substitution should be applied without first verifying dimensions, forceps geometry, patient cable connector and regulatory classification. Consult our technical department before use in tenders.
5. Selection tips and variants of interest
This adult forceps electrode with nickel-plated sensor is the economical option in the family of reusable peripheral electrodes from FIAB. If your priority is maximum signal quality and trace stability, consider the variant with silver chloride sensor F9024SSC. For paediatric patients, the same range offers references F9023SSC (Ag/AgCl) and F9023NI (nickel-plated); for overweight patients there is the variant F9024OSSC. Due to its reusable nature, always follow the manufacturer’s cleaning and disinfection instructions and periodically check the condition of the metallic coating on the sensor. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm compatibility and formal quotation.