Description
1. Commercial Introduction
The FIAB F9003NI suction precordial electrode is the reference reusable solution for taking resting electrocardiograms in adult patients. Its classic suction cup design with a 30 mm Ø rubber ring and nickel-plated sensor combines the reliability of an Italian manufacturer with decades of experience in electrocardiographs and clinical electrodes (FIAB SpA, Vicchio, Florence). Designed for cardiology practices, emergency departments, occupational medicine units and diagnostic centres, it allows you to replace or expand the thoracic electrode supply of any electrocardiograph with universal connection, with the durability and cost-effectiveness typical of a reusable product. This item is sold on quotation: contact our technical-commercial department for conditions and lead times.
2. Technical explanation of the electrode
This precordial electrode is placed on the patient’s thoracic surface and secured by the vacuum generated by the rubber bulb, without the need for adhesives or tapes. The suction cup mechanism ensures firm and reproducible contact on the chest, facilitates rapid repositioning between patients and allows simultaneous placement of the precordial leads (V1-V6) during ECG recording. The nickel-plated metal part offers adequate conductivity and a good cost-performance ratio, while the 30 mm Ø rubber ring provides a stable vacuum seal on the skin. Its universal connection allows it to be attached to virtually all patient cables of electrocardiographs and monitors on the market with a 4 mm connection.
3. Technical Specifications
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9003NI |
| Electrode size | Ø 30 mm |
| Packaging | 6 units |
| Units per box (web) | 6 |
Additional data verified against the manufacturer’s official catalogue:
| Specification | Value |
|---|---|
| Brand | FIAB |
| Original manufacturer | FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Reusable precordial suction electrode for ECG |
| Contact element | Nickel-plated sensor |
| Ring / vacuum bulb | Rubber |
| Fixation system | Suction cup, without adhesives |
| Connection | Universal (compatible with 4 mm patient cable connection) |
| Application | Resting ECG, precordial leads in adult patients |
| Use | Clinical; reusable |
| Presentation | Pack of 6 units |
4. Equivalences and Cross-References
There is no official equivalence table published by the manufacturer linking this reference to third-party codes. The following references have been cross-checked against the official catalogues and websites of each manufacturer and are classified as comparable by category (not interchangeable 1:1): any substitution must be validated beforehand by verifying the diameter (Ø 30 mm), the sensor material (nickel vs. Ag/AgCl), the suction cup system, the patient cable connector and the regulatory classification.
| Manufacturer / Brand | Family / Model | Code / SKU | Level | Observations |
|---|---|---|---|---|
| FIAB (Italy) | Suction precordial electrode, rubber ring Ø 30 mm, SSC Ag/AgCl sensor, universal connection, 6 units | F9003SSC | Comparable by category | Same diameter, rubber ring, universal connection and presentation; differs in sensor (silver/silver chloride vs. nickel). |
| Spicker GmbH (Germany) | Suction electrode for chest wall, Ø 30 mm, Ag/AgCl, universal connection, 6 units | H5 9003 | Comparable by category | The manufacturer declares FIAB SpA as the responsible manufacturer of the item; the sensor coating and the bulb differ. |
| GIMA (Italy) | Precordial thoracic electrodes Ø 30 mm, silver-plated contact, universal 4 mm connection, set of 6 | 33369 (GM33369) | Comparable by category | Matches in diameter and presentation; differs in sensor and PVC bulb. |
| Cahnos | Thoracic suction cup electrode Ag/AgCl, Ø 30 mm, pack of 6 units | 0590030 | Comparable by category | Matches in diameter and presentation; confirm contact material and connector before replacing. |
These references are cited for comparison purposes in specifications and tenders; no substitution should be applied without prior technical validation with our technical-commercial department.
5. Selection tips and variants of interest
The 30 mm diameter is the recommended size for adult patients and medium-to-large chests, where a larger capture surface is required for a robust signal. If your department prioritises an even more stable electrode potential with lower polarisation, the same FIAB family offers the version with SSC silver/silver chloride sensor (F9003SSC, Ø 30 mm); for medium-sized chests there is the Ø 24 mm version (F9009SSC) and for paediatric patients or those with a smaller chest, the Ø 15 mm version (F9008SSC). Before placing the order, check the patient cable terminal of your electrocardiograph or monitor: this electrode offers universal connection, covering most equipment on the market; if your cable has a different terminal, consult our technical department to confirm the appropriate adapter. To complete the department’s supply, combine these thoracic electrodes with ECG limb forceps and with the unipolar cables and leads from the same range. Given its reusable nature, follow the manufacturer’s cleaning and disinfection instructions and periodically check the condition of the nickel-plated coating to maintain optimal signal quality and extend the electrode’s service life. For institutional orders, tenders or continuous supply contracts, contact the technical-commercial department of Cahnos to confirm compatibility, exact reference and formal quotation.





Reviews
There are no reviews yet.