Description
1. Commercial Introduction
The disposable ECG electrode FIAB F9047 is the reference consumable for electrocardiographic monitoring in cardiology departments, emergency rooms, ICUs, hospitalisation, primary care consultations and sports medicine centres. Its rectangular foam format of 32×44 mm with conductive liquid gel, silver/silver chloride (Ag/AgCl) sensor and snap-type (press-stud) connection ensures reliable adhesion, clean trace and excellent cost per procedure in high-turnover environments. It is a universal product, suitable for both adult and paediatric patients.
2. Technical explanation of the electrode
The electrode acts as an interface between the patient’s skin and the monitor or electrocardiograph: it captures the electrical activity of the heart and transmits it with the minimum possible distortion. The foam backing with medical-grade adhesive fixes the patch firmly and comfortably throughout the recording, while the conductive liquid gel maintains moisture and skin-electrode conductivity, ensuring low contact impedance and reducing motion artefacts. The silver/silver chloride (Ag/AgCl) SSC sensor offers stable contact potential and very low polarisation, key to obtaining a clean, noise-free electrocardiogram in resting ECG, continuous monitoring and stress tests. The snap-type (press-stud) connection allows direct attachment to the lead cable with snap connector, the most common standard in monitor and electrocardiograph fleets. It is a single-use, non-sterile product, indicated for adults and paediatric population.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F9047 |
| Electrode size | 32×44 mm |
| Packaging | 1,200 units (24 bags of 50 units) |
| Units per box (web) | 1200 |
| Parameter | Specification |
|---|---|
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Disposable surface ECG electrode, single-use |
| Support | Foam with medical-grade adhesive |
| Shape | Rectangular |
| Sensor | Silver/silver chloride (Ag/AgCl) SSC |
| Gel | Conductive liquid gel |
| Connection | Snap-type (press-stud) connection |
| Population | Adult and paediatric |
| Applications | Resting electrocardiogram, continuous cardiac monitoring and stress test |
| Use | Disposable, single-use |
| Commercial classification | Product on quotation, sold in full boxes |
4. Equivalences and Cross-References
The reference F9047 corresponds to the original manufacturer code FIAB. No official manufacturer equivalence table has been found that cross-references this code 1:1 with codes from other brands; the following references from the same FIAB family have been verified in catalogue and authorised distribution and should be considered comparable by category, not interchangeable without validation by the technical department field by field (dimensions, gel type, backing and connection):
| Brand / Family | Reference | Equivalence level | Differences |
|---|---|---|---|
| FIAB | F9047 | This product | 32×44 mm, liquid gel, snap-type (press-stud) connection, foam backing, adult and paediatric |
| FIAB | F9047/4FL | Comparable by family | Same line 28×44 mm with liquid gel but 4 mm plug connection (banana); requires cable with 4 mm terminal |
| FIAB | F9047/4F | Comparable by family | 28×44 mm, 4 mm socket connection and solid gel; same family with different gel type and connector |
| FIAB | F9046 | Comparable by family | 28×44 mm with solid gel and snap-type (press-stud) connection; same dimensions and connection assembly, solid gel versus liquid |
| FIAB | F9060 / F9060P | Comparable by category | Foam electrodes with solid gel in adult oval format (48×50 mm) and paediatric round format (Ø 40 mm), snap-type connection |
As homologous families in the sector (same clinical function, always subject to verification against the official technical data sheet before any substitution) the monitoring electrodes from Ambu, 3M/Solventum Red Dot, Kendall (Cardinal Health) and Leonhard Lang (Skintact) can be cited. Any substitution must be validated by checking backing, gel type (liquid or solid), dimensions, connector type and compatibility with the equipment’s patient cable.
5. Selection tips and variants of interest
Check the terminal of your patient cable before ordering: this electrode has a snap-type (press-stud) connection, the usual standard in monitors and electrocardiographs. If your cable ends in a 4 mm banana, consider the variants of the same family with 4 mm plug connection (F9047/4FL) or consult our technical department.
Select according to clinical use: this rectangular 32×44 mm format with liquid gel is a versatile option for resting ECG and adult monitoring; for paediatric and neonatal patients, the same FIAB range includes electrodes with smaller surface area and non-woven pre-wired options that our team can advise you on.
Storage and rotation: store closed boxes in a dry, cool place to preserve the conductivity of the liquid gel, rotate stock on a FIFO basis and respect the date indicated on the packaging. As this is a single-use, high-turnover consumable, maintain a minimum stock per monitoring station. For volume orders, complete allocations or tenders, contact the technical-commercial department of Cahnos indicating the model of your monitor fleet and the connector type; this product is sold on quotation.






Reviews