Description
1. Commercial Introduction
The 3M™ RED DOT™ 2244 monitoring electrodes (reference 33292 / SKU Cahnos GM33292) are single-use disposable consumables, designed for continuous electrocardiographic monitoring in adult patients. Their foam backing with conductive adhesive gel provides firm, flexible and comfortable fixation that adapts to the thoracic contour, with the signal stability that characterises one of the most recognised families of surface electrodes on the market.
They are supplied in boxes of 50 units, a practical format for cardiology departments, ICUs, emergency departments, hospitalisation units, stress testing and purchasing centres. As an original 3M electrode, it guarantees trace homogeneity and reliability in every monitoring session.
2. Technical Explanation
The monitoring electrode acts as an interface between the patient’s skin and the monitor or recording device: it captures the heart’s electrical activity and transmits it with the minimum possible distortion. The quality of the trace depends on three key factors: adhesion (the electrode must remain fixed throughout the monitoring period), conductivity (low skin-electrode contact impedance) and stability against patient movement.
This model incorporates a foam tape with proprietary conductive adhesive gel, a breathable and flexible system that minimises irritation on sensitive skin while ensuring excellent skin contact. It is radiotransparent, so it does not interfere with imaging studies or radiography, and offers a use duration of up to 3 days, designed for medium and long-stay monitoring. Being single-use, it guarantees hygiene and prevents cross-contamination: each monitoring session begins with a new electrode, with no further skin preparation than prior cleaning and drying.
3. Technical Specifications
ECG monitoring electrode for adult patients with the following main characteristics:
| Characteristic | Value |
|---|---|
| Type | Disposable, single-use monitoring electrode |
| Code 3M | 2244 |
| Measurements | 4 x 3.25 cm |
| Support material | Foam tape with conductive adhesive gel |
| Use duration | Up to 3 days |
| Radiotransparency | Yes |
| Population | Adult |
| Application | Continuous ECG monitoring |
| Use | Single-use, disposable |
| Presentation | Box of 50 units |
Product data
| Value | Value |
|---|---|
| Brand | 3M |
| Sales unit | Box of 50 units |
| Device type | Medical device |
| Device class | I |
| CND | C020501 |
Available references
| Reference / Code | Origin | Description |
|---|---|---|
| 33292 | SKU | 3M RED DOT 2244 FOAM ELECTRODES – 4 x 3.25 cm |
| GM33292 | SKU Cahnos | 3M RED DOT 2244 electrodes – box of 50 units |
| 2244 | Code 3M | RED DOT™ family – monitoring electrode with foam backing and adhesive gel |
Note: the technical data come from the manufacturer’s official catalogue; verify the labelling of the supplied batch before use in tendering.
4. Equivalences and Cross-References
Reference 33292 is the manufacturer’s official code for this 3M RED DOT 2244 electrode, identified by the 3M code 2244. No equivalence table validated by the manufacturer has been found that authorises a 1:1 cross-reference with specific codes from other brands; any comparison between manufacturers should be understood as comparable by category (disposable monitoring electrode with foam backing and adhesive gel, adult format) and never as interchangeable without verification.
As homologous families in the category, always pending verification against the official technical data sheet, the monitoring electrodes from Skintact (Leonhard Lang), Ambu (WhiteSensor series), Kendall (Cardinal Health) and FIAB can be cited. Within the 3M™ RED DOT™ family itself, the closest variants are:
| Reference Cahnos | Code 3M | Description |
|---|---|---|
| GM33290 | 2228 | Foam electrode with adhesive gel, 3.71 x 3.25 cm |
| GM33291 | 2228BA | Foam electrode with 4 mm adapter, 3.71 x 3.25 cm |
| GM33293 | 2570 | Foam electrode with adhesive gel, 4 x 3.5 cm (up to 5 days) |
| GM33296 | 2238 | Soft cloth non-woven electrode, Ø 6 cm |
| GM33297 | 2239 | Non-woven electrode with micropore, Ø 6 cm |
| GM33378 | 2330 | Pregelled electrode for resting ECG, 3.2 x 2.2 cm |
Before any substitution, a field-by-field check must be carried out: dimensions, backing material, gel type, target population and compatibility with the monitor’s lead wire connector.
5. Selection tips and variants of interest
Monitoring duration: this foam electrode offers up to 3 days of continuous use, suitable for ICU and hospitalisation stays. For prolonged monitoring of up to 5 days, the RED DOT™ family offers model 2570 (ref. GM33293), with a slightly larger format of 4 x 3.5 cm.
Equipment connection: verify the connector type and lead wire of your monitor or electrocardiograph; if you require connection with a 4 mm adapter, consult variant 2228BA (ref. GM33291) from the same foam family.
Backing preference: if your department prefers a more breathable non-woven fabric backing instead of foam, consider the 3M RED DOT 2238 (ref. GM33296) and 2239 (ref. GM33297) models, both Ø 6 cm with up to 3 days of use.
Skin preparation: clean and dry the application area (chest) before placing the electrode, avoiding creams, hair or oily residues to optimise contact impedance and avoid repeats due to poor signal.
Storage: single-use disposable product; keep the boxes closed in a dry place and respect the expiry date on the packaging, as the gel may lose conductivity if the sachet is opened or deteriorates. For complete supplies or tenders, contact the technical-commercial department of Cahnos.





Reviews