Description
1. Introduction
The Intrafix SafeSet B.C.V. LL 180 cm (Ref. 4063001) is the intravenous infusion set from the SafeSet series designed for central and peripheral vascular access circuits in hospital wards, emergency departments, operating theatres and intensive care. It combines the two exclusive safety systems of the family —AirStop® and PrimeStop®— which protect the patient against air entry and facilitate clean, rapid priming, reducing circuit preparation time and the risk of contamination. It is supplied in a box of 100 units, the most cost-effective format for hospital stock replenishment and tenders.
2. Technical explanation of the equipment
The Intrafix SafeSet B.C.V. LL is a pressure-type (P) intravenous administration set, suitable for gravity and pressure infusion with compatible compression systems and pumps (resistant up to 2.0 bar according to ISO 8536-8). Its flexible, translucent drip chamber is calibrated to 20 drops = 1 ml (±0.1 ml), allowing the infusion rate to be calculated accurately. The AirStop® membrane, located in the drip chamber, acts as a barrier against air when the bottle is exhausted and retains particles up to 3 µm, preventing gas embolism and maintaining flow from the first to the last drop. The PrimeStop® cap, with antibacterial and hydrophobic membrane, allows priming without spills or bubbles. The DEHP-free tube is flexible and kink-resistant, with a standard intravenous spike, integrated air inlet and roller clamp to regulate flow. The distal Luer Lock connection ensures a threaded, leak-proof connection with no risk of accidental disconnection from catheters, three-way stopcocks and extension lines.
3. Technical Specifications
| Brand / Family | Braun – Intrafix (SafeSet series) |
| Manufacturer reference | 4063001 |
| Product type | Intravenous administration set |
| Configuration | B.C.V. LL (variant of the SafeSet series with Luer Lock connection) |
| Application | Infusion (vascular access) |
| Administration type | Pressure (P): gravity and pressure up to 2.0 bar (ISO 8536-8) |
| Total length | 180 cm |
| Tube diameter | Inner Ø 3.0 mm × Outer Ø 4.1 mm |
| Priming volume | ≈ 23.05 ml |
| Container connector | Standard intravenous spike (IV standard spike) |
| Terminal connection | Luer Lock (male) |
| Drip chamber calibration | 20 drops = 1 ml (±0.1 ml) |
| Filtration system | AirStop® filter in drip chamber; particle retention of 3 µm |
| Priming system | PrimeStop® (cap with antibacterial and hydrophobic membrane) |
| Ventilation | With air inlet (vented) |
| Flow regulation | Roller clamp |
| DEHP-free | Yes (SafeSet family) |
| Sterility | Sterile, single-use |
| Presentation | Box of 100 units |
4. Equivalences and Cross-References
Within the same manufacturer family (Braun – Intrafix SafeSet), the 180 cm variants with Luer Lock connector and the same box format of 100 units (SafeSet LL Ref. 4063000, SafeSet I.S. LL Ref. 4063005 and SafeSet Neutrapur LL Ref. 4063002) are reference equivalents from the same manufacturer with identical dimensions and connection, although with partially different safety features or materials. There is no official cross-reference table published by the manufacturer validating 1:1 substitutes from other brands; the following only lists products from other companies confirmed by catalogue as comparable at category level (gravity infusion sets with Luer Lock connector and similar length), not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Infineed (Didactic) | 1-way «Gravity» infusor, DEHP- and BPA-free, with Y-site | PER1YFX25 | Comparable by category (not interchangeable 1:1) | Length 150 cm + Y + 30 cm; rotating Luer Lock; 20 drops/ml chamber with 15 µm filter (compared to 3 µm for AirStop); without AirStop/PrimeStop or declared pressure use. |
| Infineed (Didactic) | 1-way «Gravity» infusor, DEHP- and BPA-free | PER1FL25 | Comparable by category (not interchangeable 1:1) | Length 160 cm; without injection port; rotating Luer Lock; 20 drops/ml chamber with 15 µm filter; without AirStop/PrimeStop or declared pressure use. |
| Farmaban | Gravity infusion set with Y-site | 2600 | Comparable by category (not interchangeable 1:1) | 185 cm; vented chamber with filter; 20 drops/ml; 15 µm filter; Luer Lock connector; sterile and latex-free; no confirmation of pressure resistance or AirStop. |
| Farmaban | Gravity infusion set | 2601 | Comparable by category (not interchangeable 1:1) | 185 cm; vented chamber with filter; 20 drops/ml; 15 µm filter; Luer Lock; without Y-site; sterile and latex-free; without AirStop/PrimeStop. |
There is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; consult the technical department before using in tenders or substitution. For any substitution between brands, the following must be checked field by field: tubing length, tube diameter, presence and porosity of the filter, terminal connector, air inlet, materials (DEHP/BPA/latex-free), sterility and regulatory classification of the actual product.
5. Selection tips and variants of interest
To choose the appropriate SafeSet variant for each clinical area:
- Intrafix SafeSet B.C.V. LL (Ref. 4063001): the model analysed; 180 cm variant with Luer Lock for vascular access circuits, with AirStop® and PrimeStop®.
- Intrafix SafeSet LL (Ref. 4063000): standard 180 cm version of the series, economical option for conventional infusion.
- Intrafix SafeSet Neutrapur LL (Ref. 4063002): recommended when the protocol requires a certified DEHP-free circuit (paediatrics, neonatology, at-risk patients).
- Intrafix SafeSet with port and CareSite (Ref. 4063004C): incorporates a needle-free valve and additional port for bolus administration.
- Intrafix SafeSet with Discofix stopcock (Ref. 4063006): integrates a three-way stopcock for multi-line circuits.
Always verify the compatibility of the Luer Lock connector (6% taper, ISO 80369-7) with the catheter or vascular access device used and confirm the requirements of your protocol (absence of DEHP, injection port or three-way stopcock) before finalising a volume purchase. Single-use product: dispose of it after each administration in accordance with the centre’s regulations.