Description
1. Commercial Introduction
The safety lancet Solofix Safety Fine from B. Braun (Ref. 6183010) is the reference option for obtaining capillary blood microsamples in patients with thin or delicate skin and in low-flow procedures. With a 25G gauge needle and 1.5 mm puncture depth, it obtains the necessary blood drop for blood glucose, HbA1c and point-of-care tests (POCT) with a superficial, quick and minimally uncomfortable puncture. A sterile single-use device designed to protect the professional and care for the patient in clinics, health centres, collection units, pharmacies and laboratories.
2. Technical explanation of the procedure
Capillary puncture is the standard method for obtaining small amounts of blood intended for glucose meters, test strips and point-of-care analytical determinations. The Solofix Safety Fine is activated by simple contact/pressure: remove the sterility cap with a twist, place the device on the clean area (fingertip, preferably on the side) and press. It requires no lancing device or prior loading steps.
The integrated safety mechanism keeps the needle hidden before and during use and, after firing, retracts it automatically and irreversibly inside the closed housing. This system complies with the philosophy of preventing accidental needlestick injuries (sharps accidents), blocks reuse of the device and facilitates its safe disposal in a sharps container in accordance with current healthcare waste regulations.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos | 6183010 |
| Official manufacturer reference | 6183010DE (B. Braun code; the DE market suffix must not be omitted or altered) |
| Pharmaceutical code (PZN) | 09042230 |
| Family | Solofix Safety |
| Product type | Sterile single-use safety lancet for capillary blood |
| Cutting element | Stainless steel needle with precision sharpening |
| Gauge | 25G |
| Puncture depth | 1.5 mm |
| Indication | Capillary puncture for blood glucose, HbA1c and rapid tests (POCT); thin skin and low-flow samples |
| Activation | By contact/pressure, without prior loading or lancing device |
| Safety mechanism | Automatic and irreversible needle retraction; cutting element hidden before and after use |
| Sterility | Yes, sterile, single-use |
| Presentation | Box of 200 units with individual sterile packaging |
Variants of the same Solofix Safety family (B. Braun):
| Reference | Variant | Features |
|---|---|---|
| 6183010 | Fine | Needle 25G × 1.5 mm – this reference (thin skin, low flow) |
| 6183000 | Universal | Needle 21G (0.8 mm) × 1.8 mm |
| 6183020 | Neonat | Blade 0.8 mm × 2.0 mm, neonatal heel |
4. Equivalences and Cross-References
The code 6183010 used by the distributor corresponds to the official B. Braun code 6183010DE (German market suffix); it must be copied literally and not reordered or modified. The following reference has been cross-checked against public documentation from the manufacturer and authorised distributors. It does not constitute a validated exact reference equivalence, but a verified functional comparison: it matches in 25G gauge, 1.5 mm puncture depth, low flow and pressure activation with automatic retraction, but differs in body design, colour and presentation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Pro Advantage (Medline) | Pressure Activated Safety Lancet | P929025 | Comparable by category (not interchangeable 1:1) | Needle 25G, 1.5 mm depth, low flow, purple colour; pressure activation with automatic retraction; box of 200 units; verified in Pro Advantage catalogue and authorised distributors. Differs in body design, colour code and presentation. |
In the reference market, homologous families of safety lancets for capillary blood also operate —such as Owen Mumford Unistik 3, Sarstedt Safety-Lancet, Vitrex Sterilance/Ultrasafe or MediPurpose SurgiLance— whose 25G/1.5 mm variants or similar gauges are not included in the table because they have not been fully cross-checked in gauge and depth against an official source with this reference (e.g., Sarstedt Safety-Lancet Mini 28G of 1.6 mm, ref. 85.1015). There is no manufacturer-validated equivalence table cross-referencing reference 6183010 with exact codes from other brands; the equivalences shown are verified functional comparisons against public sources. Consult the technical department before use in tenders or replacement of approved material.
5. Selection tips and variants of interest
Choose the Solofix Safety Fine (6183010) when the procedure requires low-flow capillary puncture on thin or delicate skin, frequent use or paediatric patients of a certain age: its 25G needle with 1.5 mm ensures a superficial and well-tolerated puncture with sufficient sample for test strips and point-of-care analysers.
For normal adult skin, consider within the same family the Solofix Safety Universal 21G (Ref. 6183000) with 1.8 mm depth; for neonatal heel, the Solofix Safety Neonat (Ref. 6183020) with a 0.8 × 2.0 mm blade. The catalogue also offers its own line of “Safety” safety blood lancets (refs. 1110115, 1110116, 1110117, 1110118 and SLN series) as comparable alternatives by category. Remember that they are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use.