Description
1. Commercial Introduction
The Solofix Safety Neonat safety lancet from B. Braun (Ref. 6183020) is the reference solution for obtaining capillary blood microsamples in the smallest patients. Specifically designed for neonates, it combines a precision blade of 0.8 mm with a puncture depth of 2.0 mm, achieving effective sample collection with minimal trauma to the baby’s delicate skin. It is the indicated device for heel puncture in neonatal screening, blood glucose monitoring in newborns, and low-volume analyses in neonatology, paediatrics, clinics, and laboratories.
Its safety mechanism with automatic and irreversible retraction protects the professional against needlestick injuries and eliminates the risk of reuse, thus complying with occupational risk prevention and sharps healthcare waste management protocols.
2. Technical explanation of the procedure
Capillary puncture is the standard method for obtaining small drops of blood for glucose meters, test strips, and point-of-care analytical determinations. In neonates, the recommended puncture site is the outer heel, where the capillary network is accessible and the risk of damaging deep structures is minimal.
Unlike other needle models, the Solofix Safety Neonat incorporates an ultra-sharp blade that guarantees an adequate blood volume and rapid healing, precisely because it is a minimally invasive linear incision. The device is activated by simple contact: remove the sterility cap, place it on the clean heel, and press. The cutting element remains hidden before and during use, and after the puncture, the needle retracts automatically and irreversibly inside the closed housing, preventing any accidental exposure. It does not require a lancet device or prior loading steps.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos | 6183020 |
| Official manufacturer reference | 6183020DE (B. Braun code; the DE market suffix must not be omitted or altered) |
| Family | Solofix Safety |
| Product type | Sterile single-use safety lancet for capillary blood |
| Cutting element | Ultra-sharp precision blade |
| Cutting element width | 0.8 mm |
| Puncture depth | 2.0 mm |
| Indication | Neonates: heel puncture and capillary blood collection |
| Identification colour | Yellow |
| Activation | By contact/pressure, without prior loading or lancing device |
| Safety mechanism | Automatic and irreversible needle retraction; cutting element hidden before and after use |
| Sterility | Yes, sterile, single-use |
| Presentation | Box of 200 units |
Note: the designation «0.8 x 2.0 mm» corresponds to the blade width (0.8 mm) and the puncture depth (2.0 mm). It is not a length of 20 mm.
Variants of the same Solofix Safety family (B. Braun):
| Reference | Variant | Features |
| 6183020 | Neonat | Blade 0.8 mm × 2.0 mm, yellow colour – this reference |
| 6183000 | Universal | Needle 21G (0.8 mm) × 1.8 mm |
| 6183010 | Fine | Needle 25G × 1.5 mm |
4. Equivalences and Cross-References
The code 6183020 used by the distributor corresponds to the official B. Braun code 6183020DE (German market suffix); it must be copied literally and not reordered or modified. The following references have been checked against public documentation from each manufacturer (official catalogue, manufacturer website, and GUDID regulatory database). None constitutes a validated exact reference equivalence, but rather a verified functional comparison: they coincide in the neonatal indication and safety philosophy, but differ in gauge, depth, activation system, or presentation.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Owen Mumford | Unistik 3 Neonatal & Laboratory | AT1052 | Comparable by category (not interchangeable 1:1) | Needle 18G with 1.8 mm depth; designed for neonatal heel sampling; activation by side button with Comfort Zone technology (as opposed to the contact activation of the Solofix Neonat); box of 100 units; verified in the official Owen Mumford catalogue and authorised distributors. |
| Sarstedt | Safety-Lancet Extra | 85.1017 | Comparable by category (not interchangeable 1:1) | Needle 18G, 1.8 mm depth; suitable for finger, ear, and heel; yellow colour (same colour code); 200 units/box; verified in GUDID (model 85.1017). |
| MediPurpose | SurgiLance Safety (blade style) | SLB200 | Comparable by category (not interchangeable 1:1) | 18G, 1.8 mm and high-flow blade-type element (approx. 74-100 µl), the closest conceptually because it uses a blade; indicated for paediatric heel; green colour; box of 100 units; verified in the manufacturer’s catalogue and authorised distributors. |
There is no manufacturer-validated equivalence table that cross-references 6183020 with exact codes from other brands; the equivalences shown are verified functional comparisons against public sources. Consult the technical department before use in tenders or replacement of approved material.
5. Selection tips and variants of interest
Choose the Solofix Safety Neonat (6183020) when the procedure requires capillary puncture in newborns or infants, especially heel puncture for neonatal screening, bilirubin determination, or blood glucose in low-weight patients. Its 0.8 mm blade with 2.0 mm depth ensures sufficient sample flow with a single puncture and rapid healing.
For thin adult skin or frequent use, consider within the same family the Solofix Safety Fine (Ref. 6183010), with a 25G needle and 1.5 mm; for normal adult skin, the Solofix Safety Universal 21G (Ref. 6183000), with 1.8 mm depth. The catalogue also offers the green Safety 18G safety lancet of 1.8 mm for paediatric heel (Ref. 1110118) as a comparable economical alternative by category. Remember that they are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use.



Reviews