We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Solofix Safety Neonat safety lancet B. Braun, blade 0.8 mm × 2.0 mm – Sterile neonatal capillary puncture | Ref. 6183020

43,60 €

Solofix Safety Neonat safety lancet (Ref. 6183020) from B. Braun: sterile single-use device for obtaining capillary blood in neonates, with precision blade of 0.8 mm and 2.0 mm puncture depth. Activation by simple contact and safety mechanism with automatic and irreversible retraction of the needle, which remains hidden before and after use. Indicated for heel puncture, neonatal screening and point-of-care testing in hospitals, neonatology units, clinics and laboratories. Supplied in a box of 200 units; official manufacturer reference: 6183020DE.

International shipping. Import duties and taxes are payable by the recipient.

Reference
6183020

Description

1. Commercial Introduction

The Solofix Safety Neonat safety lancet from B. Braun (Ref. 6183020) is the reference solution for obtaining capillary blood microsamples in the smallest patients. Specifically designed for neonates, it combines a precision blade of 0.8 mm with a puncture depth of 2.0 mm, achieving effective sample collection with minimal trauma to the baby’s delicate skin. It is the indicated device for heel puncture in neonatal screening, blood glucose monitoring in newborns, and low-volume analyses in neonatology, paediatrics, clinics, and laboratories.

Its safety mechanism with automatic and irreversible retraction protects the professional against needlestick injuries and eliminates the risk of reuse, thus complying with occupational risk prevention and sharps healthcare waste management protocols.

2. Technical explanation of the procedure

Capillary puncture is the standard method for obtaining small drops of blood for glucose meters, test strips, and point-of-care analytical determinations. In neonates, the recommended puncture site is the outer heel, where the capillary network is accessible and the risk of damaging deep structures is minimal.

Unlike other needle models, the Solofix Safety Neonat incorporates an ultra-sharp blade that guarantees an adequate blood volume and rapid healing, precisely because it is a minimally invasive linear incision. The device is activated by simple contact: remove the sterility cap, place it on the clean heel, and press. The cutting element remains hidden before and during use, and after the puncture, the needle retracts automatically and irreversibly inside the closed housing, preventing any accidental exposure. It does not require a lancet device or prior loading steps.

3. Technical Specifications

Parameter Specification
Reference Cahnos 6183020
Official manufacturer reference 6183020DE (B. Braun code; the DE market suffix must not be omitted or altered)
Family Solofix Safety
Product type Sterile single-use safety lancet for capillary blood
Cutting element Ultra-sharp precision blade
Cutting element width 0.8 mm
Puncture depth 2.0 mm
Indication Neonates: heel puncture and capillary blood collection
Identification colour Yellow
Activation By contact/pressure, without prior loading or lancing device
Safety mechanism Automatic and irreversible needle retraction; cutting element hidden before and after use
Sterility Yes, sterile, single-use
Presentation Box of 200 units

Note: the designation «0.8 x 2.0 mm» corresponds to the blade width (0.8 mm) and the puncture depth (2.0 mm). It is not a length of 20 mm.

Variants of the same Solofix Safety family (B. Braun):

Reference Variant Features
6183020 Neonat Blade 0.8 mm × 2.0 mm, yellow colour – this reference
6183000 Universal Needle 21G (0.8 mm) × 1.8 mm
6183010 Fine Needle 25G × 1.5 mm

4. Equivalences and Cross-References

The code 6183020 used by the distributor corresponds to the official B. Braun code 6183020DE (German market suffix); it must be copied literally and not reordered or modified. The following references have been checked against public documentation from each manufacturer (official catalogue, manufacturer website, and GUDID regulatory database). None constitutes a validated exact reference equivalence, but rather a verified functional comparison: they coincide in the neonatal indication and safety philosophy, but differ in gauge, depth, activation system, or presentation.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Owen Mumford Unistik 3 Neonatal & Laboratory AT1052 Comparable by category (not interchangeable 1:1) Needle 18G with 1.8 mm depth; designed for neonatal heel sampling; activation by side button with Comfort Zone technology (as opposed to the contact activation of the Solofix Neonat); box of 100 units; verified in the official Owen Mumford catalogue and authorised distributors.
Sarstedt Safety-Lancet Extra 85.1017 Comparable by category (not interchangeable 1:1) Needle 18G, 1.8 mm depth; suitable for finger, ear, and heel; yellow colour (same colour code); 200 units/box; verified in GUDID (model 85.1017).
MediPurpose SurgiLance Safety (blade style) SLB200 Comparable by category (not interchangeable 1:1) 18G, 1.8 mm and high-flow blade-type element (approx. 74-100 µl), the closest conceptually because it uses a blade; indicated for paediatric heel; green colour; box of 100 units; verified in the manufacturer’s catalogue and authorised distributors.

There is no manufacturer-validated equivalence table that cross-references 6183020 with exact codes from other brands; the equivalences shown are verified functional comparisons against public sources. Consult the technical department before use in tenders or replacement of approved material.

5. Selection tips and variants of interest

Choose the Solofix Safety Neonat (6183020) when the procedure requires capillary puncture in newborns or infants, especially heel puncture for neonatal screening, bilirubin determination, or blood glucose in low-weight patients. Its 0.8 mm blade with 2.0 mm depth ensures sufficient sample flow with a single puncture and rapid healing.

For thin adult skin or frequent use, consider within the same family the Solofix Safety Fine (Ref. 6183010), with a 25G needle and 1.5 mm; for normal adult skin, the Solofix Safety Universal 21G (Ref. 6183000), with 1.8 mm depth. The catalogue also offers the green Safety 18G safety lancet of 1.8 mm for paediatric heel (Ref. 1110118) as a comparable economical alternative by category. Remember that they are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use.

Additional information

Reference

6183020

Official manufacturer reference

6183020DE (B. Braun)

Family

Solofix Safety

Product type

Sterile single-use safety lancet for capillary blood

Cutting element

Ultra-sharp precision blade

Blade width

0.8 mm

Puncture depth

2.0 mm

Indications

Neonates: heel puncture and capillary blood collection

Activation

By contact/pressure, without prior loading or lancing device

Safety mechanism

Automatic and irreversible needle retraction; cutting element hidden before and after use

Sterility

Yes, sterile, single-use

Presentation

Box of 200 units

Use

Disposable, single-use

Color

Yellow

Reviews

There are no reviews yet.

Be the first to review “Solofix Safety Neonat safety lancet B. Braun, blade 0.8 mm × 2.0 mm – Sterile neonatal capillary puncture | Ref. 6183020”

Your email address will not be published. Required fields are marked *