Obturator Stylet/Mandrel 18G x 45 mm for Vasofix Safety Braun Catheter | Ref. 4219120 (Box of 50 units)

29,42 €

The Obturator Stylet/Mandrel 18G x 45 mm Vasofix Safety Braun (Ref. 4219120) is the official accessory for the Vasofix, Vasocan and Braunüle ranges for keeping the peripheral intravenous catheter patent when there is no active infusion. Its surgical steel rod seals the catheter lumen, prevents blood reflux, prevents thrombi and obstructions and maintains the asepsis of the line without heparinising or removing the catheter. Gauge 18G (1.3 mm), 45 mm in length, green colour code, sterile and single-use. Supplied in a box of 50 units. Essential in hospitalisation, emergency, surgery and oncology.

International shipping. Import duties and taxes are payable by the recipient.

Reference
4219120

Description

1. Introduction

The Vasofix Safety Braun 18G x 45 mm obturation mandrel/stylet, reference 4219120, is the reference accessory for keeping a peripheral intravenous catheter patent during infusion or transfusion pauses. An essential piece in hospitalisation, emergency, surgery, oncology and any unit where the patient keeps the line for several hours or days: it prevents the catheter from becoming occluded or contaminated between administrations, reduces new punctures and protects both the patient and healthcare staff. Verified in the manufacturer’s official catalogue under the designation MANDRIN/STYLET VASOFIX 18G X 45 MM (presentation CI50), it is supplied in a box of 50 sterile single-use units.

2. Technical explanation of the procedure

In peripheral intravenous cannulation, the mandrel or stylet performs a dual function. During puncture, the internal needle guides the introduction of the catheter through the skin and the vein wall; once venous return is confirmed, it is removed and the catheter remains implanted. When infusion is interrupted, the mandrel acts as an obturator: when inserted into the lumen sealing it hermetically, it prevents blood reflux into the lumen, prevents the formation of thrombi and obstructions and maintains the asepsis of the circuit without the need to heparinise or remove the line. To resume therapy, the professional removes the mandrel and reconnects the infusion line.

Reference 4219120 corresponds to gauge 18G (1.3 mm outer diameter) with 45 mm length, designed for the 45 mm catheters of the Vasofix family. Its green colour code matches that of the catheter it accompanies (according to the ISO 10555-5 coding), which facilitates its quick identification on the dressing trolley.

3. Technical Specifications

Manufacturer / Series B. Braun – Vasofix Safety (obturation stylet)
Manufacturer reference 4219120 (HAN 4219120)
Product type Obturation mandrel/stylet for peripheral catheter
Gauge 18G (1.3 mm outer diameter) – green colour code (ISO 10555-5)
Length 45 mm
Clinical function Temporary interruption of infusion/transfusion; prevents thrombi, obstructions and reflux
Compatibility Vasofix, Vasocan and Braunüle catheters
Homologous catheter Vasofix Safety G18 1.3 x 45 mm PUR (Ref. 4269136S-01)
Material High-quality surgical stainless steel
Sterility Yes, sterile (ethylene oxide)
Use Single-use / disposable
Presentation Individual sterile packaging · Box of 50 units

Vasofix Safety mandrel family (B. Braun)

Reference Gauge Length
4219201 14G (2.2 mm) 50 mm
4219171 16G (1.7 mm) 50 mm
4219139 18G (1.3 mm) 33 mm
4219120 18G (1.3 mm) 45 mm
4219104 20G (1.1 mm) 33 mm
4215095 22G (0.9 mm) 25 mm

4. Equivalences and Cross-References

Reference 4219120 has been verified in the manufacturer’s official catalogue B. Braun (Vasofix stylet series, presentation CI50) and in independent authorised distribution sources (Fisher Scientific, medipartner, among others), so the code is deemed valid.

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
B. Braun Vasofix Safety (obturation mandrel) 4219139 Comparable by category (not interchangeable 1:1) Same system and gauge 18G but length 33 mm; indicated for 33 mm Vasofix catheters.
B. Braun Introcan (obturation mandrel) 4214137 Comparable by category (not interchangeable 1:1) Gauge 18G and length 1 3/4″ (44.45 mm) very close, but Introcan catheter system with different cone geometry to Vasofix; verify compatibility before replacing.
B. Braun Vasofix Safety (obturation mandrel) 4219171 Comparable by category (not interchangeable 1:1) Same family but gauge 16G x 50 mm; for catheters of larger gauge and length.

There is no equivalence table validated by the manufacturer that allows this mandrel to be substituted 1:1 by a stylet from another brand with documentary warranty; consult the technical department before using in tenders. The equivalent families of safety catheters from other manufacturers (Venflon Pro Safety and Insyte Autoguard from BD, SafeTouch from Nipro, Leaderflex from Vygon or Intuitiv from ICU Medical) integrate the obturation into the catheter itself (blood control septum or internal needle), so they are not interchangeable 1:1 with this independent mandrel.

5. Selection tips and variants of interest

Always select the mandrel of the same gauge as the cannulated catheter and with a length matching that of the catheter: for an 18G 45 mm catheter use this reference 4219120. If your protocol uses 18G 33 mm catheters, have the variant 4219139 available. For the other gauges of the Vasofix Safety family, B. Braun offers: 4219201 (14G x 50 mm), 4219171 (16G x 50 mm), 4219104 (20G x 33 mm) and 4215095 (22G x 25 mm). At Cahnos you will also find the corresponding Vasofix Safety catheters (matching catheter G18 1.3 x 45 mm, Ref. 4269136S-01), the mandrels of the Introcan Safety line and the rest of the peripheral venous puncture material. Check the integrity of the packaging and the sterility expiry date before each use, follow aseptic technique and dispose of it after a single use in accordance with the manufacturer’s instructions.

Additional information

Manufacturer

B. Braun

Manufacturer reference

4219120 (HAN 4219120)

Product type

Obturation mandrel/stylet for peripheral catheter

Gauge

18G (1.3 mm outer diameter)

Identification colour

Green (ISO 10555-5)

Material

Surgical stainless steel

Compatibility

Vasofix, Vasocan and Braunüle catheters

Homologous catheter

Vasofix Safety G18 1.3 x 45 mm PUR (Ref. 4269136S-01)

Sterility

Yes, ethylene oxide

Presentation

Box of 50 sterile units

Use

Single-use / disposable

Clinical function

Obturation and temporary interruption of infusion

Longitud

4.5 cm