Description
1. Introduction
The 100 ml Omnifix® Irrigation Syringe with latex-free Luer adapter (Ref. 4614003F) is a medical device from the B. Braun irrigation syringe range, designed for controlled lavage and irrigation of wounds, cavities and catheter access sites. Its three-part construction in transparent polypropylene, its plunger with double sealing gasket and its integrated Luer-type adapter make it a versatile, safe and comfortable solution for healthcare professionals in hospitals, clinics, nursing practices and home care.
Being manufactured latex-free, it is especially suitable for patients with allergy or sensitivity to natural rubber, complying with the biocompatibility standards required for single-use medical devices. It is the reference tool for wound dressing procedures, urology, catheterisation and surgical cleaning that require a high flow rate and precise flow control.
2. Technical explanation of the equipment and procedure
The Omnifix® irrigation syringe works through a three-part plunger mechanism (barrel, plunger rod and sealing gasket) that allows the professional to modulate the pressure and flow rate of the liquid during irrigation. The transparent barrel with permanent high-contrast graduation allows the volume aspirated or administered to be visualised and measured accurately, avoiding dosing errors.
Its distal end incorporates a catheter cone with Luer adapter, designed for direct connection to nasogastric tubes, catheters and other drainage devices that do not use conventional Luer connections. This feature makes it ideal for bladder irrigation, lavage of catheters to maintain their patency, rinsing of surgical wounds and cavity lavage, as well as for enteral feeding in certain clinical protocols.
The plunger incorporates a safety stop (plunger backstop) that prevents accidental withdrawal of the plunger rod during handling, and the double sealing gasket ensures stable movement, slow and controlled suction and prevention of leaks throughout the entire use cycle.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 4614003F |
| Brand / Range | B. Braun — Omnifix® |
| Product type | Three-part irrigation syringe, sterile, single-use |
| Nominal capacity | 100 ml |
| Construction | 3 pieces (barrel, plunger rod and gasket) |
| Cone type | Catheter cone with Luer adapter |
| Cone position | Centric |
| Material | Polypropylene (barrel and plunger rod); latex-free elastomer gasket |
| Graduation | Permanent high-contrast scale |
| Latex | Latex-free |
| Sterility | Sterile, single-use |
| Applications | Wound and cavity irrigation, bladder lavage, maintenance of catheters and probes |
4. Equivalences and Cross-References
The reference 4614003F belongs to the B. Braun Omnifix® range and its code corresponds to the 100 ml version with Luer adapter (catheter cone). It has been verified in official catalogues and authorised B. Braun distributors that the code matches the description Omnifix irrigation 100 ml, latex-free, Luer adapter tip, so it can be considered confirmed. There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; alternatives from the same family and comparable by category, verified against official sources, are listed below:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| B. Braun — Omnifix® | 50/60 ml irrigation syringe, catheter cone, latex-free | 4613503F | Comparable by category (not interchangeable 1:1) | Same family and mechanism as the 4614003F; lower capacity (50/60 ml); requires more refill cycles for large-volume irrigations. |
| BD — Plastipak™ | 100 ml syringe with catheter cone and Luer adapter | 300605 | Comparable by category (not interchangeable 1:1) | Same capacity and catheter cone with Luer adapter; graduation scale of 2 ml; presentation in carton of 25 units. Different manufacturer: verify traceability and registrations. |
| Cahnos | 100 ml piston irrigation syringe | 620100 | Comparable by category (not interchangeable 1:1) | Alternative from the Cahnos range itself; same capacity (100 ml) with cone-type connection; verify adapter type according to the centre’s protocol. |
There is no manufacturer-validated equivalence table for this reference; consult the technical department before use in tenders. Before substituting, check one by one: nominal capacity, type and position of the cone, plunger material (latex-free), sterility, graduation scale and commercial presentation, as compliance with all fields is essential to consider an alternative.
5. Selection tips and variants of interest
To choose the appropriate irrigation syringe, consider the procedure volume: the 4614003F (100 ml) is the recommended option for large-volume lavages requiring fewer refill cycles; if the required flow rate is lower, the 4613503F (50/60 ml) variant from the same Omnifix® family offers greater manoeuvrability. In the B. Braun Omnifix® syringe range, the F ending of the code identifies the latex-free version of the irrigation family.
Always verify the integrity of the sterile packaging before each use and use the syringe as a single-patient product, according to your centre’s protocol. For volume purchase conditions, continuous supply contracts or group purchasing organisation budgets, contact the technical-commercial team at Cahnos.





Reviews