Description
1. Commercial Introduction
The PRIMEDIC HeartSave PAD is an automated external defibrillator (AED) from the recognised HeartSave platform, designed to equip any cardiac-protected space quickly and reliably: workplaces, sports centres, schools, health centres, ambulances and public administrations. Its design philosophy pursues a single objective: that any person, even without a healthcare background, can act safely in the event of a cardiorespiratory arrest. It switches on automatically when the lid is opened, guides the responder with clear voice prompts at every stage of the resuscitation and delivers the shock with advanced, individualised and effective biphasic technology. For large orders you can request a quote: contact your Cahnos technical-commercial adviser for supply conditions.
2. Technical explanation of the equipment and procedure
The HeartSave PAD operates in semi-automatic mode: the device analyses the patient’s heart rhythm through the pre-connected electrodes and, only if it detects ventricular fibrillation or shockable ventricular tachycardia, tells the responder to press the shock button. The CCD (controlled current defibrillation) technology generates a biphasic pulse without current peaks, individualised and gentle on the patient’s cardiac muscle, with a stepped energy strategy, impedance compensation and maximum energy of 360 J.
The device is designed to minimise the peri-shock pause and the no-flow fraction, maximising the effectiveness of the resuscitation. The paediatric mode is selected with a single button, without the need for dedicated paediatric electrodes, which simplifies maintenance and reduces costs. In addition, the device switches on automatically when the lid is opened, the pre-connected electrodes allow the rhythm analysis to start immediately and the lid contains the necessary accessories (razor, ventilation face mask, scissors and gloves). A status display permanently reports on the operational status of the defibrillator and the battery, thanks to the daily and monthly self-tests.
3. Technical Specifications
3.1. Main features
| Parameter | Specification |
|---|---|
| Operating mode | Semi-automatic |
| Shock technology | Biphasic, controlled-current pulse (CCD) |
| Energy | 50–360 J |
| Weight-bearing time | < 12 s at 360 J |
| Operating modes | Asynchronous |
| Paediatric mode | Yes, selectable with one button |
| Patient impedance (ECG) | 23–200 ohms |
| VF/VT detection | Yes; analysis time 7–12 sec |
| Asystole threshold | < 0.2 mV |
| Pacemaker detection | Yes (pacemaker artefact) |
| Electrodes | Non-polarised, with 2 m cable (SavePads) |
| Data backup | Removable memory and voice recording |
| Power supply | Lithium battery, 3 years standby life or 140 shocks at 360 J |
| Status display | Display of defibrillator and battery status |
3.2. Included accessories
- Lithium battery, 3 years standby (140 shocks at 360 J)
- SavePads electrodes
- Data and voice recording
- Manual
3.3. Available references
| Reference | Language | Sales unit |
|---|---|---|
| GM33393 | IT | 1 pc |
| GM33395 | GB | 1 pc |
| GM33398 | FR | 1 pc |
3.4. Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | Z12030501 |
| GMDN | 37806 |
4. Equivalences and Cross-References
The distribution reference GM33393-F corresponds to code 33393 (Italian version) in the Product_DB database; codes 33395 (English) and 33398 (French) are the language variants of the same defibrillator, with no technical differences. The device belongs to the HeartSave platform of the Metrax-Primedic group (Metrax GmbH), original manufacturer of the family.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Observations |
|---|---|---|---|
| Catalogue Cahnos | PRIMEDIC HeartSave PAD (IT variant) | 33393 / GM33393-F | SKU covered by this datasheet; Italian language. |
| Catalogue Cahnos | PRIMEDIC HeartSave PAD (GB variant) | 33395 | Same device, voice prompts in English. |
| Catalogue Cahnos | PRIMEDIC HeartSave PAD (FR variant) | 33398 | Same device, voice prompts in French. |
| Metrax-Primedic | Original adult SavePads (3-point connector) | 96343 | Electrodes for the HeartSave platform; verify connector and serial range. |
| Metrax-Primedic | Original SavePads for HeartSave AED before 2014 | 96387 | First generation; differences in connector and packaging format. |
| Metrax-Primedic | Original PreConnect SavePads (new generation, from 2014) | 97085 | Pre-connected 12-point connector; verify device F code. |
| Catalogue Cahnos | Adult SavePads-SET up to S.N. 738XXXXXXX | 35388 | Original electrodes for the HeartSave platform in earlier generations. |
| Catalogue Cahnos | Paediatric SavePads MINI (1–8 years / up to 25 kg) | 35390 | Paediatric spare part for HeartSave from S.N. 739XXXXXXX. |
| Catalogue Cahnos | Adult/child PreConnect-Set SavePads (from 1 year) | 35392 | Pre-connected configuration from S.N. 739XXXXXXX. |
| Cahnos | Compatible adult electrodes (external cable) | F7960W | Compatible alternative for the Metrax-Primedic platform. |
| Cahnos | Compatible adult radiotransparent electrodes | F7760W | Compatible alternative suitable for artefact-free imaging. |
| Metrax-Primedic | Batteries for the HeartSave family | 97640 / 97641 / 97642 / 97196 | Power spare parts documented in the Cahnos catalogue; verify device model and generation. |
There is no equivalence table validated by the manufacturer that cross-references this defibrillator with platforms from other manufacturers (Philips HeartStart, ZOLL, Stryker LIFEPAK, Bexen Reanibex, among others): the connectors, analysis algorithms and energy management are proprietary and are not interchangeable 1:1. Contact the technical department of Cahnos before any substitution in a tender.
5. Selection tips and variants of interest
- Choose the appropriate language variant: this datasheet corresponds to the Italian version (GM33393-F); if your organisation operates in Spanish or other environments, consult the GM33395 (English) and GM33398 (French) variants available in the same catalogue.
- Plan your consumables: verify the model, serial number and connector type of your device before purchasing replacement electrodes (SavePads), and follow the expiry rotation (FIFO). For paediatric care, have the appropriate electrode pair available or use the integrated paediatric mode.
- Preventive maintenance: the non-rechargeable lithium battery provides 3 years of standby life or 140 shocks at 360 J; carry out the replacement according to the device maintenance plan and the status display, without waiting for the low-battery warning.
- Equipping cardiac-protected spaces: the automatic-opening design, voice prompts and accessories integrated into the lid make it especially suitable for facilities without permanent healthcare staff.
- Institutional orders: For tenders, consortia or fleets, contact the technical-commercial department of Cahnos indicating the desired models and language references.