Description
1. Introduction
The Endotracheal Tube Endosid with low-pressure cuff and Murphy eye, 4.5 mm (Ref. 841045) is a single-use medical device designed for safe airway management in paediatric patients, young children and small adults with reduced-calibre airways. Its design combines a low-pressure inflation cuff, which provides a reliable, airtight seal against the tracheal mucosa, with the classic Murphy eye, which guarantees an alternative ventilation route if the distal lumen becomes obstructed. It is the option recommended by our specialists for long-duration procedures, mechanical ventilation and anaesthetic techniques requiring maximum control of tidal volume and airway pressure in demanding environments such as the operating theatre, ICU or emergency departments.
2. Technical Explanation
The endotracheal tube is inserted into the trachea to secure a patent airway and allow mechanical ventilation or administration of anaesthesia. In this configuration, the low-pressure inflation cuff is inflated through a one-way valve with pilot balloon, achieving a distal seal that prevents gas leaks, protects the airway against aspiration and allows the pressure to be adjusted precisely. The Murphy eye, a lateral opening located next to the distal tip, acts as an alternative ventilation route: if the main lumen becomes obstructed by secretions or kinking, airflow continues through this opening, ensuring respiratory continuity. Its transparent medical-grade material allows the patency of the circuit to be verified during placement, while the radiopaque contrast line facilitates radiographic confirmation of tube position. The atraumatic distal tip reduces the risk of injury during insertion and its standard 15 mm connector (ISO 5356-1) guarantees compatibility with virtually all circuits and ventilators on the market.
3. Technical Specifications
The technical features of the Endosid Endotracheal Tube with cuff and Murphy eye, 4.5 mm, are summarised in the following table:
| Parameter | Specification |
| Reference | 841045 |
| Inner diameter | 4.5 mm |
| Type | With inflation cuff and Murphy eye |
| Inflation cuff | Yes, low-pressure, with valve and pilot balloon |
| Murphy eye | Yes, distal alternative ventilation route |
| Material | Medical-grade PVC, transparent, flexible and durable |
| Connector | 15 mm standard (ISO 5356-1) |
| Radiopacity | Yes, radiopaque contrast line for imaging control |
| Latex | Free of natural rubber latex |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 10 units in individual sterile packaging |
| Use | Disposable, single-use |
| Clinical application | Orotracheal intubation with airtight seal; paediatric, infant patients and narrow airways |
| Use environments | Operating theatre, ICU, emergency departments and anaesthesia |
The Endosid family with cuff and Murphy eye (series 841xxx) covers a complete range of sizes for neonatal, paediatric, infant and narrow-airway intubation:
| Gauge | Reference |
| 2 mm | 841020 |
| 2.5 mm | 841025 |
| 3 mm | 841030 |
| 3.5 mm | 841035 |
| 4 mm | 841040 |
| 4.5 mm | 841045 |
| 5 mm | 841050 |
| 5.5 mm | 841055 |
| 6 mm | 841060 |
| 6.5 mm | 841065 |
| 7 mm | 841070 |
| 7.5 mm | 841075 |
| 8 mm | 841080 |
| 8.5 mm | 841085 |
| 9 mm | 841090 |
| 9.5 mm | 841095 |
| 10 mm | 841100 |
4. Equivalences and Cross-References
This tube is part of the Endosid airway management family from Cahnos and corresponds to the version with cuff and Murphy eye in size 4.5 mm. Complementary references in the same size include: the standard Magill tube without cuff (Ref. 840045), the version without cuff and without Murphy eye (Ref. 842045) and the version without cuff with Murphy eye (Ref. 843045). For rapid intubation settings, the family also includes emergency kits (series 845xxx, Ref. 845045) that integrate this type of tube with the essential accessories. The standard 15 mm connector complies with ISO 5356-1, so the device is compatible with virtually all circuits and ventilators on the market and can be replaced by equivalent-size endotracheal tubes from other manufacturers that comply with the applicable regulations (e.g. codes such as 100/111/045 or 100/141/045 in conventional ranges of cuffed tubes with Murphy eye). Always verify the size and configuration (with or without cuff and with or without Murphy eye) before replacing one reference with another.
5. Selection tips and variants of interest
Size selection should be based on the patient’s age, weight and anatomy: for neonates and premature infants, sizes from 2 to 3.5 mm are used; for infants and young children, sizes from 3.5 to 5 mm (which includes this 4.5 mm tube); and for older children or narrow airways, sizes from 5.5 to 6 mm. This cuffed version is especially recommended for long-duration procedures or when an airtight airway seal, ventilation with controlled pressures or protection against aspiration is required. It is advisable to check the integrity of the cuff and pilot valve before intubation and to keep cuff pressure below 25-30 cmH2O to avoid injury to the tracheal mucosa. The Murphy eye provides additional safety in the event of a risk of distal obstruction by secretions or kinking. To complete the range, Endosid offers intubation stylets, emergency kits and the remaining sizes in series 841. Contact our technical-commercial team for reference approval and high-volume orders.