Description
Oral reinforced endotracheal tube with cuff and Murphy eye ID 9.5 mm
The oral reinforced endotracheal tube with cuff and Murphy eye of 9.5 mm (ref. ETA095C02A2) is a single-use airway management device, designed for orotracheal intubation of large adult patients in the operating theatre, intensive care units, emergency departments and resuscitation. Its structure reinforced with a helical spiral makes it the reference option when stability of the airway is needed during head and neck movements, frequent repositioning or prolonged positive-pressure ventilation. It is supplied in a box of 10 units with individual sterile packaging, ideal for departmental stock and the intubation trolley.
Technical explanation of the device
The tube is inserted orally through the glottis into the trachea and is connected at its proximal end to the ventilator, anaesthesia circuit or resuscitation bag via the universal 15 mm connector (in accordance with ISO 5356-1).
- Helical reinforcement: spiral integrated into the tube wall that prevents kinking and collapse of the airway, maintaining airway patency during mechanical ventilation.
- Sealing cuff: distal balloon that, once inflated, creates an airtight seal in the trachea, prevents air leakage during positive-pressure ventilation and reduces the risk of aspiration and tube displacement.
- Murphy eye: distal lateral safety opening that ensures airflow even if the tube tip becomes occluded by contact with the tracheal or bronchial wall.
- Material: medical-grade polyvinyl chloride (PVC), transparent, flexible and latex-free.
Technical specifications
| Parameter | Specification |
|---|---|
| Reference | ETA095C02A2 |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 9.5 mm |
| Configuration | Reinforced with sealing cuff |
| Reinforcement | Helical anti-kink |
| Murphy eye | Yes, distal lateral safety opening |
| Material | Medical-grade polyvinyl chloride (PVC), latex-free |
| Connector | Universal 15 mm (ISO 5356-1) |
| Use | Single-use, non-reusable |
| Sterilisation | Sterile, individual packaging |
| Presentation | Box of 10 units |
| Indicative population | Large adult |
This size is part of the Cahnos range of oral reinforced endotracheal tubes with cuff, available in several diameters to complete departmental stock:
| Reference | ID (mm) |
|---|---|
| ETA035C02A2 | 3.5 |
| ETA045C02A2 | 4.5 |
| ETA055C02A2 | 5.5 |
| ETA065C02A2 | 6.5 |
| ETA075C02A2 | 7.5 |
| ETA085C02A2 | 8.5 |
| ETA090C02A2 | 9.0 |
| ETA095C02A2 (this product) | 9.5 |
Equivalences and cross-references
Reference ETA095C02A2 is a catalogue code specific to Cahnos and could not be cross-referenced with an official third-party manufacturer code in public sources: there is no manufacturer-validated equivalence table; consult the Cahnos technical department before use in tenders or as a replacement for stock from other brands.
Comparable by category within the Cahnos catalogue (same 9.5 mm size, not 1:1 interchangeable):
| Reference | Description | Key difference |
|---|---|---|
| ETAN95C02 | Oral endotracheal tube with cuff and Murphy eye ID 9.5 mm | Without helical anti-kink reinforcement |
| ETAM95C02A1 | Oral reinforced endotracheal tube with cuff, stylet and Murphy eye ID 9.5 mm | Includes insertion stylet and helical reinforcement |
| ETA095002A2 | Oral reinforced endotracheal tube without cuff and with Murphy eye ID 9.5 mm | Without cuff; sealed by size contact |
At market level, 9.5 mm oral reinforced endotracheal tubes with cuff fall into the same functional category as product lines from manufacturers such as Teleflex (Rüsch), Medtronic (Shiley), ICU Medical (Portex), Intersurgical or Medline (ENDOSID): same general clinical indication, but it is essential to verify in each technical data sheet the internal diameter, material, presence of Murphy eye and sterilisation standard before replacing the device in a care protocol.
Selection tips and variants of interest
The 9.5 mm ID is reserved for large adult patients; as a general guide, tubes of 7.0 to 9.5 mm are used in adults depending on build and airway, always selecting the largest size compatible with the patient’s anatomy.
The cuffed configuration is the appropriate option for prolonged positive-pressure ventilation, general anaesthesia and situations requiring an airtight seal and prevention of aspiration; cuff inflation pressure should be monitored during the procedure and kept within the range indicated in the care protocol.
If the procedure demands maximum resistance to kinking or frequent repositioning, this reinforced model is the right choice. If an insertion stylet is also required, the version with stylet (ETAM95C02A1) is available; for protocols where avoiding the cuff is preferred, the uncuffed variant (ETA095002A2) is available. Complete the intubation trolley stock with adjacent sizes from the reinforced range (ETA090C02A2, ETA085C02A2) and consult your Cahnos technical-commercial representative for volume conditions and hospital supply lead times.